Neutron fluence and energy spectra around the Varian Clinac 2100C/2300C medical accelerator

被引:75
|
作者
Kase, KR
Mao, XS
Nelson, WR
Liu, JC
Kleck, JH
Elsalim, M
机构
[1] Stanford Univ, Stanford Linear Accelerator Ctr, Stanford, CA 94309 USA
[2] Varian Corp, Palo Alto, CA 94304 USA
[3] Sci Applicat Int Corp, Santa Clara, CA 95054 USA
来源
HEALTH PHYSICS | 1998年 / 74卷 / 01期
关键词
Monte Carlo; shielding; accelerators; neutrons;
D O I
10.1097/00004032-199801000-00005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We have simulated the head geometry of a Varian Clinac 2100C/2300C medical accelerator in a Monte Carlo calculation to produce photoneutrons and transport them through the head shielding into a typical therapy room (modeled by a test cell at Varian Associates), The fast neutron leakage fluence and energy spectra have been calculated at 7 positions around the linac head for typical beam operation at 10, 15, 18 and 20 MV. The results of these calculations have been compared with limited measurements made using the same model accelerator operating in a Varian test cell. Calculations were also made for the fluence and energy spectra outside the head with no surrounding concrete walls, floor or ceiling to eliminate the effects of scattering from concrete, Comparisons were also made with calculations using a much simplified head geometry, The results indicate that the calculations using the complex head geometry compare, within the uncertainties, with the measurements, The simple head geometry leads to differences of a factor of 2 from the complex geometry. Results of these calculations can be used to calculate fast neutron transmission through various shielding configurations and through labyrinths.
引用
收藏
页码:38 / 47
页数:10
相关论文
共 21 条
  • [1] Neutron sources in the Varian Clinac 2100C/2300C medical accelerator calculated by the EGS4 code
    Mao, XS
    Kase, KR
    Liu, JC
    Nelson, WR
    Kleck, JH
    Johnsen, S
    HEALTH PHYSICS, 1997, 72 (04): : 524 - 529
  • [2] Simulation of photon energy spectra from Varian 2100C and 2300C/D Linacs: Simplified estimates with PENELOPE Monte Carlo models
    Baumgartner, Andreas
    Steurer, Andreas
    Maringer, Franz Josef
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (11) : 2007 - 2012
  • [3] Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    A. Ma
    J. Awotwi-Pratt
    A. Alghamdi
    A. Alfuraih
    N. M. Spyrou
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 119 - 123
  • [4] Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    Ma, A.
    Awotwi-Pratt, J.
    Alghamdi, A.
    Alfuraih, A.
    Spyrou, N. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 119 - 123
  • [5] The physical characteristics of the 15 MV Varian Clinac 2100C unflattened beam
    Najem, M. A.
    Spyrou, N. M.
    Podolyak, Z.
    Abolaban, F. A.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 205 - 209
  • [6] Evaluation of neutron spectra and dose equivalent from a Varian 2100C/D Medical Linear Accelerator: Monte Carlo simulation and a literature review
    Razghandi, S.
    Karimi-Shahri, K.
    Firoozabadi, M. M.
    RADIOPROTECTION, 2021, 56 (02) : 93 - 101
  • [7] “Dosimetric aspects of physical and dynamic wedges of the clinac 2100C linear accelerator”
    T. Wiezorek
    D. Harder
    Strahlentherapie und Onkologie, 1998, 174 : 105 - 105
  • [8] Dosimetric aspects of physical and dynamic wedges of the Clinac 2100C linear accelerator - Comment
    Wiezorek, T
    Harder, D
    STRAHLENTHERAPIE UND ONKOLOGIE, 1998, 174 (02) : 105 - 105
  • [9] Measurement of photoneutrons in the output of 15 MV varian clinac 2100C LINAC using bubble detectors
    Awotwi-Pratt, J. B.
    Spyrou, N. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (03) : 679 - 684
  • [10] Varian Clinac 2100C加速器真空度降低的检修
    杨绍洲
    杨光
    中国医疗器械杂志, 1999, (03) : 59 - 59