Pachymetric mapping with Fourier-domain optical coherence tomography

被引:69
|
作者
Li, Yan
Tang, Maolong
Zhang, Xinbo
Salaroli, Camila H.
Ramos, Jose L.
Huang, David [1 ]
机构
[1] Doheny Eye Inst, Ctr Ophthalm Opt & Lasers, Los Angeles, CA 90033 USA
来源
关键词
CENTRAL CORNEAL THICKNESS; IN-SITU KERATOMILEUSIS; ULTRASOUND PACHYMETRY; HIGH-SPEED; ORBSCAN-II; REFRACTIVE SURGERY; VISANTE; KERATOCONUS; AGREEMENT; PENTACAM;
D O I
10.1016/j.jcrs.2009.11.016
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the repeatability of Fourier-domain optical coherence tomography (OCT) pachymetric mapping and compare central corneal thickness (CCT) measurements by OCT, ultrasound pachymetry, and scanning-slit tomography. SETTING: Doheny Eye Institute, University of Southern California, Los Angeles, California, USA. METHODS: A Fourier-domain OCT system was used to map the corneal thickness in normal eyes with scans centered on the corneal vertex or the pupil. Repeatability of central and pericentral map sectors was assessed by pooled standard deviation. The CCT measurements were compared between the OCT, ultrasound, and scanning-slit devices. RESULTS: Pupil centration (SD: 1.3 mu m central, 1.8 to 3.8 mu m pericentral) provided better repeatability than vertex centration (SD: 1.7 mu m central, 2.4 to 5.7 mu m pericentral) in all sectors (P<.035). The mean CCT was 536.9 mu m +/- 27.0 (SD) by OCT, 556.6 +/- 30.5 mu m by ultrasound, and 537.2 +/- 32.6 mu m by scanning-slit tomography (acoustic factor 0.92). The CCT measured by OCT was significantly thinner than by ultrasound pachymetry (P = .007; mean difference -19.7 mu m; 95% limits of agreement [LoA], -40.4 to 0.9 mu m) but not than by scanning-slit tomography (P = .2637; mean difference -0.3 mu m; 95% LoA, -24.0 to 23.5 mu m). The CCT by OCT correlated well with ultrasound and scanning-slit CCTs (r = 0.940 and r = 0.934, respectively). CONCLUSION: Pachymetric mapping with Fourier-domain OCT was highly repeatable. Repeatability was better with pupil-centered scans than with corneal vertex centered scans. Ultrasound pachymetry, Fourier-domain OCT, and scanning-slit tomography should not be used interchangeably for CCT assessment.
引用
收藏
页码:826 / 831
页数:6
相关论文
共 50 条
  • [1] Pachymetric Mapping Repeatability Using Fourier-Domain Optical Coherence Tomography in Corneal Opacities
    El Gendy, N. M. Samy
    Li, Y.
    Huang, D.
    Zhang, X.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [2] Fourier phase in Fourier-domain optical coherence tomography
    Uttam, Shikhar
    Liu, Yang
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (12) : 2286 - 2306
  • [3] Repeatability of Pachymetric Mapping Using Fourier Domain Optical Coherence Tomography in Corneas With Opacities
    El Gendy, Nehal M. Samy
    Li, Yan
    Zhang, Xinbo
    Huang, David
    CORNEA, 2012, 31 (04) : 418 - 423
  • [4] Time-domain interpolation for Fourier-domain optical coherence tomography
    Zhang, Yudong
    Li, Xiqi
    Wei, Ling
    Wang, Kai
    Ding, Zhihua
    Shi, Guohua
    OPTICS LETTERS, 2009, 34 (12) : 1849 - 1851
  • [5] Characterization of coated optical fibers by Fourier-domain optical coherence tomography
    Jasapara, J
    Wielandy, S
    OPTICS LETTERS, 2005, 30 (09) : 1018 - 1020
  • [6] Macular thickness of Chinese with fourier-domain optical coherence tomography
    Yu Weihong
    Zheng Lin
    Dai Rongping
    Zhang Zhiqiao
    Dong Fangtian
    ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E104 - E105
  • [7] Corneal power measurement with Fourier-domain optical coherence tomography
    Tang, Maolong
    Chen, Alex
    Li, Yan
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2115 - 2122
  • [8] Reproducibility of intracoronary Fourier-domain optical coherence tomography analysis
    Orii, M.
    Kubo, T.
    Kitabata, H.
    Ishibashi, K.
    Yamano, T.
    Tanimoto, T.
    Ino, Y.
    Yamaguchi, T.
    Imanishi, T.
    Akasaka, T.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1000 - 1000
  • [9] Fourier-domain optical coherence tomography: next step in optical imaging
    Wojtkowski, M
    Kowalczyk, A
    Targowski, P
    Gorczynska, I
    OPTICA APPLICATA, 2002, 32 (04) : 569 - 580
  • [10] Time-gated Fourier-domain optical coherence tomography
    Muller, Matthew S.
    Webster, Paul J. L.
    Fraser, James M.
    OPTICS LETTERS, 2007, 32 (22) : 3336 - 3338