Temperature coefficient of sensitivity dependence of the measurement error of quartz crystal resonators

被引:1
|
作者
Jia, RG [1 ]
Wang, JS [1 ]
Feng, GP [1 ]
机构
[1] TSING HUA UNIV, DEPT PRECIS INSTRUMENTS, BEIJING 100084, PEOPLES R CHINA
关键词
D O I
10.1109/58.656641
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper discusses the measurement error of quartz crystal resonators (QXRs) vs, the temperature coefficient of force sensitivity. Based on the analysis of the difference between the temperature coefficient of frequency and the temperature coefficient of force sensitivity, the measurement error formula is deduced. According to the error formula, the physical significance of the temperature coefficient of force sensitivity is explained, and the method of selecting a scale temperature is given. The measurement error formula has been verified recently by experimental results. To expand the selectable range of cut modes and to compare the performances of QXRs, the selecting principle of the best group of the angles of cut of quartz crystal plate, theta, psi, and azimuth angle of applied force, Psi is given simultaneously. According to the measurement error formula and the selecting principle of the best group of the angles, the best azimuth angle of AT-cut used as force sensitive resonators is found through the analysis of the measurement error. This paper provides a theoretical basis on which the measurement accuracy of QXR force sensors can be improved.
引用
收藏
页码:1376 / 1381
页数:6
相关论文
共 50 条
  • [1] Temperature coefficient of sensitivity dependence of the measurement error of quartz crystal resonators
    Jia, RG
    Wang, JS
    Feng, GP
    PROCEEDINGS OF THE 1996 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (50TH ANNIVERSARY), 1996, : 493 - 500
  • [2] Radial dependence of mass sensitivity for modified-electrode quartz crystal resonators
    Lee, Y
    Josse, F
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 321 - 325
  • [3] Analysis of the radial dependence of mass sensitivity for modified-electrode quartz crystal resonators
    Josse, F
    Lee, Y
    Martin, SJ
    Cernosek, RW
    ANALYTICAL CHEMISTRY, 1998, 70 (02) : 237 - 247
  • [4] The temperature coefficient of quartz crystal oscillators
    Strout, RS
    PHYSICAL REVIEW, 1928, 32 (05): : 0829 - 0831
  • [5] TEMPERATURE-DEPENDENCE OF THE INTRINSIC MECHANICAL Q OF AT-CUT QUARTZ-CRYSTAL RESONATORS
    YU, I
    SONG, YW
    PHYSICA B, 1994, 194 : 431 - 432
  • [6] TEMPERATURE COEFFICIENT OF AT CUT QUARTZ CRYSTAL VIBRATORS
    GERBER, EA
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1955, 43 (10): : 1529 - 1529
  • [7] Measurements of temperature coefficient and pressure coefficient of quartz crystal oscillators
    Brown, SL
    Harris, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1931, 2 (03): : 180 - 183
  • [8] Behavior of Quartz Crystal Resonators at Liquid Helium Temperature
    Galliou, Serge
    Abbe, Philippe
    Goryachev, Maxim
    Ivanov, Eugene N.
    Tobar, Michael. E.
    Bourquin, Roger
    2016 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2016,
  • [9] The effect of contour concentricity on the acceleration sensitivity of quartz crystal resonators
    Morley, Peter E.
    2015 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & THE EUROPEAN FREQUENCY AND TIME FORUM (FCS), 2015, : 427 - 431
  • [10] Determination of mass sensitivity of crystal quartz resonators at students' laboratory
    Greczylo, Tomasz
    Mazur, Piotr
    Debowska, Ewa
    Wieczorek, Piotr
    EUROPEAN JOURNAL OF PHYSICS, 2010, 31 (02) : 257 - 265