Norian SRS cement augmentation in hip fracture treatment - Laboratory and initial clinical results

被引:0
|
作者
Goodman, SB
Bauer, TW
Carter, D
Casteleyn, PP
Goldstein, SA
Kyle, RF
Larsson, S
Stankewich, CJ
Swiontkowski, MF
Tencer, AF
Yetkinler, DN
Poser, RD
机构
[1] Stanford Univ, Sch Med, Div Orthopaed Surg, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Div Biomech Engn, Stanford, CA 94305 USA
[3] Cleveland Clin Fdn, Dept Pathol, Cleveland, OH 44195 USA
[4] Free Univ Brussels, Dept Orthopaed Surg, Brussels, Belgium
[5] Univ Michigan, Dept Orthopaed Surg, Ann Arbor, MI 48109 USA
[6] Hennepin Cty Med Ctr, Dept Orthopaed Surg, Minneapolis, MN 55415 USA
[7] Univ Uppsala Hosp, Dept Orthopaed Surg, Uppsala, Sweden
[8] Univ Washington, Harborview Med Ctr, Dept Orthopaed Surg, Seattle, WA 98104 USA
[9] Norian Corp, Cupertino, CA USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Bone quality, initial fracture displacement, severity of fracture comminution, accuracy of fracture reduction, and the placement of the internal fixation device are important factors that affect fixation stability, New high strength cements that are susceptible to remodeling and replacement far fracture fixation may lead to improved clinical outcome in the treatment of hip fractures, Norian SRS is an injectable, fast setting cement that cures in vivo to form an osteoconductive carbonated apatite of high compressive strength (55MPa) with chemical and physical characteristics similar to the mineral phase of bone, It can be used as a space filling internal fixation device to facilitate the geometric reconstruction, load transfer, and healing of bone with defects and/or fractures in regions of cancellous bone, Furthermore, this cement can improve the mechanical holding strength of conventional fixation devices, Use of this material potentially could improve fracture stability, retain anatomy during fracture healing and improve hip function, thus achieving better clinical outcomes, In vi ro animal studies hale shown the materials biocompatibility, and cadaveric studies have shown the biomechanical advantage of its use in hip fractures, Initial clinical experience (in 52 femoral neck fractures and 39 intertrochanteric fractures) showed the potential clinical use of this innovative cement in the treatment of hip fractures.
引用
收藏
页码:42 / 50
页数:9
相关论文
共 50 条
  • [1] SRS cancellous bone cement augmentation of galcaneal fracture fixation
    Thordarson, DB
    Bollinger, M
    FOOT & ANKLE INTERNATIONAL, 2005, 26 (05) : 347 - 352
  • [2] Norian SRS augmentation in revision of acetabular cup of total hip arthroplasty.: A follow up of six patients
    Mueller, M.
    Stangl, R.
    UNFALLCHIRURG, 2006, 109 (04): : 335 - 338
  • [3] The results of screw augmentation of acetabular cement spacers for the treatment of periprosthetic hip joint infection
    Jing-Yao Jin
    Taek-Rim Yoon
    Kyung-Soon Park
    Sheng-Yu Jin
    Dong-Min Jung
    Qing-Song Li
    Journal of Orthopaedic Surgery and Research, 15
  • [4] The results of screw augmentation of acetabular cement spacers for the treatment of periprosthetic hip joint infection
    Jin, Jing-Yao
    Yoon, Taek-Rim
    Park, Kyung-Soon
    Jin, Sheng-Yu
    Jung, Dong-Min
    Li, Qing-Song
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [5] Treatment of fractures of the distal radius with a remodellable bone cement - A prospective, randomised study using Norian SRS
    Sanchez-Sotelo, J
    Munuera, L
    Madero, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06): : 856 - 863
  • [6] Is Cement Augmentation a Viable Treatment Option for an Osteoporotic Compression Fracture?
    Chaudhary, Saad B.
    Savage, Jason W.
    CLINICAL SPINE SURGERY, 2018, 31 (05): : 185 - 187
  • [7] Norian-SRS-Augmentation bei Revision der Hüfttotalendoprothesen-PfannenkomponenteEine Nachuntersuchung von 6 PatientenNorian SRS augmentation in revision of acetabular cup of total hip arthroplastyA follow up of six patients
    M. Müller
    R. Stangl
    Der Unfallchirurg, 2006, 109 (4): : 335 - 338
  • [8] Results of Continued Care in the Treatment of Hip Fracture
    Suarez Monzon, Horacio
    Yero Arniella, Luis Angel
    Rodriguez Fernandez, FLix R.
    Aguila Tejeda, Gerardo
    MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS, 2016, 14 (02): : 173 - 179
  • [9] Open Reduction and Internal Fixation of Displaced Intra-articular Calcaneal Fractures with Norian Skeletal Repair System (SRS) Bone Cement: Surgical Technique, Clinical and Radiographical Results
    Yeo, Quan You
    Kwek, Ernest B. K.
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2014, 43 (10) : 515 - 516
  • [10] Prevention of hip lag screw cut-out by cement augmentation: Description of a new technique and preliminary clinical results
    Szpalski, M
    Descamps, PY
    Hayez, JP
    Raad, E
    Gunzburg, R
    Keller, TS
    Kosmopoulos, V
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (01) : 34 - 40