Comparative study on the efficacy of the UHMWPE surface modification by chemical etching and electrostatic spraying method for drug release by orthopedic implants

被引:16
|
作者
Kumar, R. Manoj [1 ,2 ]
Haldar, Swati [3 ]
Rajesh, K. [1 ]
Ghosh, Souvik [3 ]
Lahiri, Debrupa [1 ,3 ]
机构
[1] Indian Inst Technol Roorkee, Dept Met & Mat Engn, Biomat & Multiscale Mech Lab, Roorkee 247667, Uttar Pradesh, India
[2] Madanapalle Inst Technol & Sci, Dept Mech Engn, Angallu 517325, Madanapalle, India
[3] Indian Inst Technol Roorkee, Ctr Nanotechnol, Tissue Engn Lab, Roorkee 247667, Uttar Pradesh, India
关键词
Orthopedic implant; Bacterial infection; Drug delivery; Surface modification; Tribology; MOLECULAR-WEIGHT POLYETHYLENE; REVISION TOTAL HIP; ARTHROPLASTY; INFECTION; GENTAMICIN; COATINGS; TRENDS; FILMS; WEAR;
D O I
10.1016/j.msec.2019.110117
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Failure of fixation between bone and implant surface due to bacterial infection, is one of the key challenges in total hip arthroplasty. It might lead to poor implant stability and complex revision surgery. Surface modification of an acetabular cup liner for sustained drug delivery is an effective approach to reduce the biofilms associated infection. The aim of the study is to evaluate the influence of different surface modification technique on drug delivery, mechanical and tribological performances of the acetabular cup liner. Solvent-based etching and electrostatic spray deposition technique was individually used to engineer a thin microporous surface layer on ultra-high molecular weight polyethylene (UHMWPE), which is commercially used as acetabular cup liner in total hip implant. Porous surfaces were filled with drug (gentamicin) containing biodegradable polymer (chitosan) through impregnation process and their efficacy was compared in the intended application. The surfaces, modified by both techniques, have shown lower friction coefficient. The higher wear rates were noticed for electrostatic sprayed coating. Both the modified surfaces have shown slight decrease in hardness and elastic modulus, which may be attributed to improper impregnation of polymer inside porous surface. However, after the release of drug, the solvent-based etched surface regains its mechanical and tribological properties, in similar range to the unmodified UHMWPE surface. Both the modified surfaces have shown an impressive drug release profile and in vitro antibacterial efficacy. The drug release duration was more for electrostatic spray modified surface. Hence, these surfaces modified implant parts shown great promise for fighting against post-surgery bacterial infection.
引用
收藏
页数:12
相关论文
共 3 条
  • [1] Nanoparticles and Liposomes for the Surface Modification of Implants: A Comparative Study of Spraying and Dipping Techniques
    Seitz, Benjamin S.
    Plenagl, Nikola
    Raschpichler, Michael
    Voegeling, Hendrik
    Wojcik, Matthias
    Pinnapireddy, Shashank R.
    Bruessler, Jana
    Bakowsky, Udo
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2018, 215 (15):
  • [2] Comparative Study of Surface Chemical Composition and Oxide Layer Modification upon Oxygen Plasma Cleaning and Piranha Etching on a Novel Low Elastic Modulus Ti25Nb21Hf Alloy
    Virginia Paredes
    Emiliano Salvagni
    Enrique Rodríguez-Castellón
    José María Manero
    Metallurgical and Materials Transactions A, 2017, 48 : 3770 - 3776
  • [3] Comparative Study of Surface Chemical Composition and Oxide Layer Modification upon Oxygen Plasma Cleaning and Piranha Etching on a Novel Low Elastic Modulus Ti25Nb21Hf Alloy
    Paredes, Virginia
    Salvagni, Emiliano
    Rodriguez-Castellon, Enrique
    Maria Manero, Jose
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2017, 48A (08): : 3770 - 3776