Evaluation of a multicapillary electrophoresis instrument for mitochondrial DNA typing

被引:0
|
作者
Stewart, JEB [1 ]
Aagaard, PJ
Pokorak, EG
Polanskey, D
Budowle, B
机构
[1] Natl Missing Person DNA Database, DNA Anal Unit 2, FBI Lab, FBI Acad,Sci Anal Sect, Quantico, VA 22135 USA
[2] FBI Lab, Washington, DC USA
关键词
forensic science; mitochondrial DNA sequencing; polymerase chain reaction; capillary electrophoresis; validation; mtDNA;
D O I
暂无
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Laser-induced detection of fluorescent labeled PCR products and multi-wavelength detection (i.e., multicolor analysis) enables rapid generation of mtDNA sequencing profiles. Traditionally, polyacrylamide slab gels have been used as the electrophoretic medium for mtDNA sequencing in forensic analyses. Replacement of slab gel electrophoresis with capillary electrophoresis (CE) can facilitate automation of the analytical process. Automation and high throughput can be further enhanced by using multicapillary electrophoretic systems. The use of the ABI Prism(R) 3100 Genetic Analyzer (ABI 3100, Applied Biosystems, Foster City, CA) as well as the ABI Prism(TM) 310 Genetic Analyzer (ABI 310, Applied Biosystems, Foster City, CA) were evaluated for mtDNA sequencing capabilities and compared with sequencing results obtained on the platform currently in use in the FBI Laboratory (the ABI Prism(TM) 377 DNA Sequencer, ABI 377, Applied Biosystems, Foster City, CA). Various studies were performed to assess the utility of the ABI 3100, as well as the ABI 310 for mtDNA sequencing. The tests included: comparisons of results obtained among the ABI 3100, the ABI 310 and the ABI 377 instruments; comparisons of results obtained within and between capillary arrays; evaluation of capillary length; evaluation of sample injection time; evaluation of the resolution of mixtures/heteroplasmic samples; and evaluation of the sensitivity of detection of a minor component with reduced template on the ABI 3100. In addition, other studies were performed to improve sample preparation; these included: comparison of template suppression reagent (TSR, Applied Biosystems, Foster City, CA) versus formamide; the use of Performa(TM) DTR Gel Filtration Cartridges (Edge BioSystems(TM) Inc., Gaithersburg, MD) versus Centri-Sep Spin Columns (Princeton Separations, Adelphia, NJ) for product purification after cycle sequencing; and sample stability after denaturation. The data support that valid and reliable results can be obtained using either capillary electrophoresis instrument, and the quality of sequencing results are comparable to or better than those obtained from the ABI 377 instrument.
引用
收藏
页码:571 / 580
页数:10
相关论文
共 50 条
  • [1] A fully automated multicapillary electrophoresis device for DNA analysis
    Abteilung Lehrach, Max-Planck-Inst. F. Molec. Genetik, Berlin-Dahlem, Germany
    不详
    Electrophoresis, 7 (1492-1507):
  • [2] A fully automated multicapillary electrophoresis device for DNA analysis
    Behr, S
    Mätzig, M
    Levin, A
    Eickhoff, H
    Heller, C
    ELECTROPHORESIS, 1999, 20 (07) : 1492 - 1507
  • [3] Design of an automated multicapillary instrument with fraction collection for DNA mutation discovery by constant denaturant capillary electrophoresis (CDCE)
    Li, QB
    Deka, C
    Glassner, BJ
    Arnold, K
    Li-Sucholeiki, XC
    Tomita-Mitchell, A
    Thilly, WG
    Karger, BL
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (12) : 1375 - 1389
  • [4] Guidelines for mitochondrial DNA typing
    Bär, W
    Brinkmann, B
    Budowle, B
    Carracedo, A
    Gill, P
    Holland, M
    Lincoln, PJ
    Mayr, W
    Morling, N
    Olaisen, B
    Schneider, PM
    Tully, G
    Wilson, M
    VOX SANGUINIS, 2000, 79 (02) : 121 - 125
  • [5] EVALUATION OF A NEW BLOOD TYPING INSTRUMENT
    ROWE, AL
    TRANSFUSION, 1983, 23 (02) : 173 - 174
  • [6] Capillary electrophoresis for forensic DNA typing analyses
    Budowle, B
    Isenberg, AR
    PROGRESS IN FORENSIC GENETICS 7, 1998, 1167 : 61 - 67
  • [7] Cost benefit analysis of a multicapillary electrophoresis system
    Amirkhanian, Varouj
    Lui, Ming
    Guttman, Andras
    Szantai, Eszter
    AMERICAN LABORATORY, 2006, 38 (13) : 26 - +
  • [8] Haplotyping of the deoxycytidine kinase gene by multicapillary electrophoresis
    Szantai, E
    Ronai, Z
    Sasvari-Szekel, M
    Guttman, A
    ANALYTICAL BIOCHEMISTRY, 2006, 352 (01) : 148 - 150
  • [9] Mitochondrial DNA typing for forensic analysis.
    Dugan, KA
    Lawrence, HS
    Fisher, CL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U304 - U304
  • [10] Rapid analysis of colipase gene variants by multicapillary electrophoresis
    Jaczo, Zsuzsanna
    Pal, Eszter
    Denes, Reka
    Somogyi, Aniko
    Sasvari-Szekely, Maria
    Guttman, Andras
    Ronai, Zsolt
    ELECTROPHORESIS, 2015, 36 (11-12) : 1237 - 1243