Precision of light intensity measurement in biological optical microscopy

被引:14
|
作者
Bernas, Tytus
Barnes, David
Asem, Elikplimi K.
Robinson, J. Paul
Rajwa, Bartek
机构
[1] Silesian Univ, Fac Biol & Protect Environm, Dept Plant Anat & Cytol, Katowice, Poland
[2] Purdue Univ, Cytometry Labs, W Lafayette, IN 47907 USA
[3] Quantitat Imaging Corp, Burnaby, BC V5C 6C6, Canada
[4] Purdue Univ, Sch Vet Med, W Lafayette, IN 47907 USA
关键词
CCD camera; dynamic range; fluorescence; intensity resolution; noise; photon transfer; quantitative microscopy;
D O I
10.1111/j.1365-2818.2007.01764.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Standardization and calibration of optical microscopy systems have become an important issue owing to the increasing role of biological imaging in high-content screening technology. The proper interpretation of data from high-content screening imaging experiments requires detailed information about the capabilities of the systems, including their available dynamic range, sensitivity and noise. Currently available techniques for calibration and standardization of digital microscopes commonly used in cell biology laboratories provide an estimation of stability and measurement precision (noise) of an imaging system at a single level of signal intensity. In addition, only the total noise level, not its characteristics (spectrum), is measured. We propose a novel technique for estimation of temporal variability of signal and noise in microscopic imaging. The method requires registration of a time series of images of any stationary biological specimen. The subsequent analysis involves a multi-step process, which separates monotonic, periodic and random components of every pixel intensity change in time. The technique allows simultaneous determination of dark, photonic and multiplicative components of noise present in biological measurements. Consequently, a respective confidence interval (noise level) is obtained for each level of signal. The technique is validated using test sets of biological images with known signal and noise characteristics. The method is also applied to assess uncertainty of measurement obtained with two CCD cameras in a wide-field microscope.
引用
收藏
页码:163 / 174
页数:12
相关论文
共 50 条
  • [1] Polarimetric microscopy for optical control and high precision measurement of valley polarization
    Yoo, SeokJae
    Park, Q-Han
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (06):
  • [2] Light Microscopy at Maximal Precision
    Bierbaum, Matthew
    Leahy, Brian D.
    Alemi, Alexander A.
    Cohen, Itai
    Sethna, James P.
    PHYSICAL REVIEW X, 2017, 7 (04):
  • [3] PRECISION-MEASUREMENT OF PARTICULATES BY LIGHT-SCATTERING AT OPTICAL RESONANCE
    MARSHALL, TR
    PARMENTER, CS
    SEAVER, M
    SCIENCE, 1975, 190 (4212) : 375 - 377
  • [4] DEPOLARIZED LIGHT INTENSITY AND OPTICAL MICROSCOPY OF SOME MESOPHASE-FORMING MATERIALS
    BARRALL, EM
    SWEENEY, MA
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1969, 5 (03): : 257 - &
  • [5] Effect of light spot intensity on precision of displacement measurement based on position sensitive detector
    Zhang, Peng
    Tan, Ai-Ying
    Chen, Wei-Min
    Zhang, Yi
    Guangzi Xuebao/Acta Photonica Sinica, 2014, 43 (04):
  • [6] LIGHT OPTICAL MICROSCOPY
    VANDERVOORT, GF
    JOURNAL OF METALS, 1988, 40 (07): : A10 - A10
  • [7] Light microscopy in biological research
    Kozubek, S
    BIOPHYSICAL JOURNAL, 2005, 88 (06) : 3741 - 3741
  • [8] PRECISION OPTICAL WAVEFRONT MEASUREMENT
    SCHAHAM, M
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 306 : 183 - 191
  • [9] Measurement precision of optical scatterometry
    Logofatu, PC
    McNeil, JR
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XV, 2001, 4344 : 447 - 453
  • [10] Optical Precision for Measurement and Inspection
    不详
    MANUFACTURING ENGINEERING, 2015, 154 (01): : 38 - +