BUILDING ENERGY MODEL CALIBRATION: A CASE STUDY USING COMPUTATIONAL FLUID DYNAMICS WITH AIR LEAKAGE TESTING AND ON-SITE WEATHER DATA

被引:0
|
作者
Fu, Tat S. [1 ]
Lyon, Edward G. [1 ]
机构
[1] SGH, Waltham, MA 02451 USA
关键词
SIMULATION-MODELS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Whole building energy models of existing buildings are infrequently validated because of model complexity and the availability of reliable data. In this paper, the authors consider two important building energy simulation components - measured whole-building air leakage rates and on-site weather data - and study their effects on creating an accurate energy model of an existing office building in Massachusetts, USA using computational fluid dynamics (CFD) analysis. This case study shows that on-site weather data is critical in calibrating building energy models and that CFD analysis has a greater influence during a heating season compared to a cooling season in a cold climate.
引用
收藏
页码:558 / 564
页数:7
相关论文
共 50 条
  • [1] Building model calibration using energy and environmental data
    Royapoor, Mohammad
    Roskilly, Tony
    ENERGY AND BUILDINGS, 2015, 94 : 109 - 120
  • [2] Calibration of a Building Energy Model Using Measured Data
    Monfet, Danielle
    Zmeureanu, Radu
    Charneux, Roland
    Lemire, Nicolas
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 1, 2009, 115 : 348 - +
  • [3] Methane Emission Outbursts in the Mine Face of Two Galleries: Computational Fluid Dynamics Analysis and On-Site Calibration
    Torno, Susana
    Torano, Javier
    ENERGIES, 2023, 16 (21)
  • [4] Building energy model calibration: A detailed case study using sub-hourly measured data
    Guyot, Dimitri
    Giraud, Florine
    Simon, Florian
    Corgier, David
    Marvillet, Christophe
    Tremeac, Brice
    ENERGY AND BUILDINGS, 2020, 223
  • [5] Indoor air quality maintenance in an air conditioned building using computational fluid dynamics
    Robin, JR
    Kalaiselvam, S
    Iniyan, S
    Samuel, AA
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 599 - 602
  • [6] On-Site Calibration of an Electric Drive: A Case Study Using a Multiphase System
    Soto-Marchena, David
    Barrero, Federico
    Colodro, Francisco
    Arahal, Manuel R.
    Mora, Jose L.
    SENSORS, 2023, 23 (17)
  • [7] Quantifying the Building Energy Dynamics of Manhattan, New York City, Using an Urban Building Energy Model and Localized Weather Data
    Li, Wenliang
    ENERGIES, 2020, 13 (12)
  • [8] A Framework for Input Data Processing During Building Energy Model Calibration A Case Study
    Stavrakantonaki, Marina
    ECAADE 2015: REAL TIME - EXTENDING THE REACH OF COMPUTATION, VOL 1, 2015, : 625 - 634
  • [9] A computational fluid dynamics study of the effects of buoyancy on air flow surrounding a building
    Yau, Y. H.
    Lian, Y. C.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (03): : 257 - 271
  • [10] Optimal Positioning of Small Wind Turbines Into a Building Using On-Site Measurements and Computational Fluid Dynamic Simulation
    Diaz, Alexander Vallejo
    Moya, Idalberto Herrera
    Castellanos, Juan E.
    Lara, Edwin Garabitos
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2024, 146 (08):