Purpose: The purpose of this study was to determine whether MR with and without SPIO (AMI-25) could replace spiral-CTAP in the staging of colorectal adenocarcinoma. Material and Methods: Thirty-five patients were studied prospectively by means of i.v. contrast-enhanced spiral-CT, spiral-CTAP, and MR of the liver. MR imaging was performed before and after infusion of AMI-25. Diagnoses were compared to intraoperative findings (n=35) which included intraoperative ultrasound (n=21), and follow-up CT (n=18). Results and Conclusion; Fifteen patients were found to have a total number of 53 liver metastases and 43 benign lesions were detected. Evaluation was performed in four different ways: 1) i.v. contrast-enhanced spiral-CT; 2) i.v. contrast-enhanced spiral-CT + spiral-CTAP; 3) plain MR; 4) plain MR + SPIO-enhanced MR. I.v. contrast-enhanced spiral-CT, spiral-CTAP and SPIO-enhanced MR identified patients with liver metastases with equal sensitivity. However, owing to its significantly higher sensitivity, based on a lesion-by-lesion analysis, spiral-CTAP cannot be replaced by SPIO-enhanced MR in patients who are to undergo liver resection. A limitation in spiral-CTAP is its relatively low specificity.
引用
收藏
页码:986 / 992
页数:7
相关论文
共 50 条
  • [1] Diagnosis of liver metastases from colorectal adenocarcinoma: Comparison of spiral-CTAP combined with intravenous contrast-enhanced spiral-CT and SPIO-enhanced MR combined with plain MR imaging
    Strotzer, Michael
    Gmeinwieser, J.
    Schmidt, J.
    Fellner, C.
    Seitz, J.
    Albrich, H.
    Zirngibl, H.
    Feuerbach, S.
    Acta Radiologica, 38 (06): : 986 - 992
  • [2] Value of SPIO-enhanced breath-hold MR imaging of the liver: Comparison with contrast-enhanced spiral CT
    Holzknecht, NG
    Gauger, J
    Schurig, J
    Helmberger, TK
    Sachmann, M
    Reiser, MF
    RADIOLOGY, 1996, 201 : 1210 - 1210
  • [3] Comparison of unenhanced MR imaging, SPIO-enhanced MR imaging, and spiral-CT for hepatic lesion detection and characterization: Results of a ROC-analysis
    Reimer, P
    Fiebich, M
    Deckers, FP
    Schima, W
    Holzknecht, NG
    Saini, S
    RADIOLOGY, 1999, 213P : 170 - 170
  • [5] Liver metastases in candidates for hepatic resection: Comparison of helical CT and gadolinium- and SPIO-enhanced MR imaging
    Ward, J
    Robinson, PJ
    Guthrie, JA
    Downing, S
    Wilson, D
    Lodge, JPA
    Prasad, KR
    Toogood, GJ
    Wyatt, JI
    RADIOLOGY, 2005, 237 (01) : 170 - 180
  • [6] Hepatic metastases: Detection with multi-detector row CT, SPIO-enhanced MR imaging, and both techniques combined
    Onishi, H
    Murakami, T
    Kim, T
    Hori, M
    Iannaccone, R
    Kuwabara, M
    Abe, H
    Nakata, S
    Osuga, K
    Tomoda, K
    Passariello, R
    Nakamura, H
    RADIOLOGY, 2006, 239 (01) : 131 - 138
  • [7] A prospective study of MR, contrast-enhanced spiral CT, and CT arterio-portography in the staging of patients with colorectal liver metastases for resection
    Bhattacharjya, S
    Bhattacharjya, T
    Tibballs, JM
    Watkinson, AF
    Davidson, BR
    RADIOLOGY, 2001, 221 : 108 - 108
  • [8] Comparison of unenhanced and contrast-enhanced spiral CT for assessing interval change in patients with colorectal liver metastases
    Park, JH
    Nazarian, LN
    Halpern, EJ
    Feld, RI
    Lev-Toaff, AS
    Parker, L
    Wechsler, RJ
    ACADEMIC RADIOLOGY, 2001, 8 (08) : 698 - 704
  • [9] Colorectal hepatic metastases: Detection with SPIO-enhanced breath-hold MR imaging - Comparison of optimized sequences
    Ward, J
    Guthrie, JA
    Wilson, D
    Arnold, P
    Lodge, JP
    Toogood, GJ
    Wyatt, JI
    Robinson, PJ
    RADIOLOGY, 2003, 228 (03) : 709 - 718
  • [10] Detection of liver metastases: Prospective comparison of unenhanced and superparamagnetic iron oxide-enhanced MR imaging, dual-phase spiral-CT, and spiral CT during arterial portography
    Lencioni, RA
    Laiolo, E
    Pinto, F
    Donati, F
    Giulianotti, P
    Bartolozzi, C
    RADIOLOGY, 1997, 205 : 971 - 971