The Use of Semi-Absorbable Mesh and its Impact on Donor-Site Morbidity and Patient-Reported Outcomes in DIEP Flap Breast Reconstruction

被引:20
|
作者
Siegwart, L. C. [1 ]
Sieber, L. [1 ]
Fischer, S. [1 ]
Diehm, Y. [1 ]
Hirche, C. [1 ]
Kneser, U. [1 ]
Kotsougiani-Fischer, D. [1 ]
机构
[1] Heidelberg Univ, Burn Ctr, BG Trauma Ctr Ludwigshafen Hand & Plast Surg, Dept Hand Plast & Reconstruct Surg,Microsurg, Ludwig Guttmann Str 13, D-67071 Ludwigshafen, Germany
关键词
DIEP; Breast reconstruction; Mesh; Donor-site morbidity; Hernia;
D O I
10.1007/s00266-020-02096-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background This study aimed to evaluate the impact of semi-absorbable mesh on donor-site morbidity and patient-reported outcomes in deep inferior epigastric perforator (DIEP) flap breast reconstruction. Methods We conducted a retrospective cohort study of all patients who had DIEP flap breast reconstruction in our department from July 2007 to March 2019. Patients were invited to a comparative follow-up visit and grouped according to donor-site closure: primary fascial closure (the no-mesh group) and fascial reinforcement with semi-absorbable mesh in a subfascial position (the mesh group). The primary outcome of interest was donor-site morbidity, including bulging, hernia formation and rectus abdominis muscle strength. We also surveyed, surgical site complications and patient-reported outcomes using Patient and Observer Scar Assessment Scale v2.0 and BREAST-Q(C) version 2.0. Results A total of 191 patients had received DIEP flap breast reconstruction. Eighty-five patients (44.5%) with 108 DIEP flaps (53 patients in the mesh group and 32 patients in the no-mesh group) were included in the study. The mean BMI of the patients was significantly higher in the mesh group (mesh group, 26.9 vs. no-mesh group, 25.0, with p = 0.03). The incidence of hernia was significantly reduced in the mesh group (mesh group, 2.8% vs. no-mesh group, 13.5%, with p = 0.03). The incidence of bulging and the extent of rectus abdominis muscle strength were similar for both groups. Operative surgical site complications were reduced in the mesh group (mesh group, 7.5% vs. no-mesh group, 18.8%). There was no difference in patients' physical well-being and satisfaction with the donor site between groups. Patient-reported scar outcome was significantly better in the no-mesh group (p < 0.001). Conclusion Our novel method of donor-site closure with semi-absorbable mesh in a subfascial position for reinforcement of the anterior rectus fascia on the DIEP donor site is safe. It has no negative impact on surgical site complications and patient-reported outcomes, while reducing the incidence of hernias on the donor-site in DIEP flap breast reconstruction. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
引用
收藏
页码:907 / 916
页数:10
相关论文
共 50 条
  • [1] The Use of Semi-Absorbable Mesh and its Impact on Donor-Site Morbidity and Patient-Reported Outcomes in DIEP Flap Breast Reconstruction
    L. C. Siegwart
    L. Sieber
    S. Fischer
    Y. Diehm
    C. Hirche
    U. Kneser
    D. Kotsougiani-Fischer
    Aesthetic Plastic Surgery, 2021, 45 : 907 - 916
  • [2] Invited Discussion on: "The Use of Semi-absorbable Mesh and Its Impact on Donor-Site Morbidity and Patient-Reported Outcomes in DIEP Flap Breast Reconstruction"
    Taghizadeh, Rieka
    AESTHETIC PLASTIC SURGERY, 2021, 45 (03) : 917 - 920
  • [3] Invited Discussion on: “The Use of Semi-absorbable Mesh and Its Impact on Donor-Site Morbidity and Patient-Reported Outcomes in DIEP Flap Breast Reconstruction”
    Rieka Taghizadeh
    Aesthetic Plastic Surgery, 2021, 45 : 917 - 920
  • [4] Comparison of outcomes and donor-site morbidity in unilateral free TRAM versus DIEP flap breast reconstruction
    Schaverien, M. V.
    Perks, A. G. B.
    McCulley, S. J.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2007, 60 (11): : 1219 - 1224
  • [5] DIEP free flap breast reconstruction: review of impact of surgical procedure on donor site morbidity
    Tomouk, T.
    Mohan, A. T.
    Azizi, A.
    Conci, E.
    Brickley, E. B.
    Malata, C. M.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 50 - 50
  • [6] Long-term patient-reported donor-site morbidity after free peroneal fasciocutaneous flap in head and neck reconstruction
    Lee, Shih-Yu
    Yang, Kuo-Chung
    Lin, Cheng-Ta
    Ho, Yen-Yi
    Chen, Lee-Wei
    Liu, Wen-Chung
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2023, 51 (07)
  • [7] Risk factors for abdominal donor-site morbidity in free flap breast reconstruction
    Vyas, Raj M.
    Dickinson, Brian P.
    Fastekjian, Jaco H.
    Watson, James P.
    Dalio, Andrew L.
    Crisera, Christopher A.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (05) : 1519 - 1526
  • [8] Donor-site morbidity of the inferior gluteal musculocutaneous flap for breast reconstruction in teenagers
    Dupere, Sophie
    Bergeron, Leonard
    Bortoluzzi, Patricia
    Del-Duca, Tina
    Caouette-Laberge, Louise
    ANNALS OF PLASTIC SURGERY, 2007, 59 (06) : 617 - 620
  • [9] To Ablate or Not to Ablate: Does Umbilectomy Decrease Donor-Site Complications in DIEP Flap Breast Reconstruction?
    Perez, Kevin
    Teotia, Sumeet S.
    Haddock, Nicholas T.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 153 (02) : 305 - 314
  • [10] Patient-reported donor-site morbidity following anterolateral thigh free flaps
    Lipa, JE
    Novak, CB
    Binhammer, PA
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2005, 21 (06) : 365 - 370