Modeling of Joint Operation of a Ground Soil Heat Exchanger and a Thermal Pump Evaporator

被引:0
|
作者
Sydorchuk, Bogdan [1 ]
Naumchuk, Oleksandr [1 ]
Mazurek, Pawel A. [2 ]
机构
[1] Natl Univ Water & Environm Engn, Dept Automat & Comp Integrated Technol, 11 Soborna St, UA-33028 Rivne, Ukraine
[2] Lublin Univ Technol, Fac Elect Engn & Comp Sci, Ul Nadbystrzycka 38A, PL-20618 Lublin, Poland
来源
JOURNAL OF ECOLOGICAL ENGINEERING | 2021年 / 22卷 / 02期
关键词
ground heat exchanger; thermal pump;
D O I
10.12911/22998993/131177
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The development of civilization is associated with an increase in demand for energy. Nowadays, the technologies using renewable energy sources are particularly important. The heating systems powered by heat pumps are increasingly used. The article presents an integrated mathematical model that takes into account the joint operation of the ground heat exchanger and the internal circuit of the heat pump. Modeling was done in Matlab environment. The modeling results allow optimizing the evaporator design in order to effectively use the heat pump.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [1] Influence of ground heat exchanger zoning operation on operation economy of ground source heat pump systems
    Yu M.
    He Z.
    Mao Y.
    Cui P.
    Zhang W.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (01): : 205 - 212
  • [2] CUMULATIVE EFFECTS OF OPERATION OF VAPOUR COMPRESSOR HEAT PUMP WITH GROUND HEAT EXCHANGER
    Hanuszkiewicz-Drapala, Malgorzata
    Skladzien, Jan
    RYNEK ENERGII, 2011, (05): : 58 - 65
  • [3] Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger
    Michopoulos, A.
    Zachariadis, T.
    Kyriakis, N.
    ENERGY, 2013, 51 : 349 - 357
  • [4] The influence of soil thermal properties on the operation performance on ground source heat pump system
    Li, Biao
    Han, Zongwei
    Bai, Chenguang
    Hu, Honghao
    RENEWABLE ENERGY, 2019, 141 : 903 - 913
  • [5] Experimenting and Modeling Thermal Performance of Ground Heat Exchanger Under Freezing Soil Conditions
    Tu, Shuyang
    Yang, Xiuqin
    Zhou, Xiang
    Luo, Maohui
    Zhang, Xu
    SUSTAINABILITY, 2019, 11 (20)
  • [6] Modeling And Simulation Of The Interaction Between Soil And The Heat Exchanger Pipe Of A Heat Pump
    Neacsu, Sorin
    Suditu, Silvian
    Popescu, Catalin
    CREATING GLOBAL COMPETITIVE ECONOMIES: A 360-DEGREE APPROACH, VOLS 1-4, 2011, : 2243 - 2250
  • [7] Impact of Seasonal Heat Accumulation on Operation of Geothermal Heat Pump System with Vertical Ground Heat Exchanger
    Timofeev, D. V.
    Malyavina, E. G.
    INTERNATIONAL CONFERENCE ON CONSTRUCTION, ARCHITECTURE AND TECHNOSPHERE SAFETY (ICCATS 2017), 2017, 262
  • [8] Numerical modelling of transient soil temperature distribution for horizontal ground heat exchanger of ground source heat pump
    Kayaci, Nurullah
    Demir, Hakan
    GEOTHERMICS, 2018, 73 : 33 - 47
  • [9] Zoning operation of energy piles to alleviate the soil thermal imbalance of ground source heat pump systems
    You T.
    Zeng W.
    Energy and Built Environment, 2023, 4 (01): : 57 - 63
  • [10] Analysis of Groundwater Advection and Ground-Heat Exchanger Spacing on Intermittent Ground-Source Heat Pump Operation
    Lines, Scott Harold
    Llano-Serna, Marcelo A.
    Williams, David J.
    ENERGY GEOTECHNICS, SEG-2018, 2019, : 19 - 26