Conjugate forced convection transient flow and heat transfer analysis in a hexagonal, partitioned, air filled cavity with dynamic modulator

被引:25
|
作者
Ikram, Maruf Md [1 ]
Saha, Goutam [2 ]
Saha, Suvash C. [3 ]
机构
[1] Bangladesh Univ Engn & Technol BUET, Dept Mech Engn, Dhaka 1000, Bangladesh
[2] Univ Dhaka DU, Dept Math, Dhaka 1000, Bangladesh
[3] Univ Technol Sydney UTS, Sch Mech & Mechatron Engn, Sydney, NSW 2007, Australia
关键词
Transient analysis; Flow modulator; Biot number; FFT analysis; thermo-oscillation frequency; ROTATING CIRCULAR-CYLINDER; SQUARE OUTER CYLINDER; NATURAL-CONVECTION; MIXED CONVECTION; ENCLOSURE; SIMULATION; ALGORITHM; ANNULUS; BODIES;
D O I
10.1016/j.ijheatmasstransfer.2020.120786
中图分类号
O414.1 [热力学];
学科分类号
摘要
Background: - Forced convection heat transfer in a cavity is of great importance due to its strong relevance to the practical aspects. Most of the studies focus on this topic from a steady perspective. But adding a flow modulator enhances a system's thermodynamic performance and makes such a system more realistic and widens the field of application. Such studies are unsteady and often quite expensive. As a result, only a few literatures are available with very idealistic geometric configuration and boundary conditions. Methodology: - Two-dimensional unsteady continuity, momentum and energy equations are used for the mathematical modeling of the problem incorporating the Boussinesq approximation. A free triangular discretization scheme is adopted to solve the moving mesh problem by formulating the Arbitrary Lagrangian Euler (ALE) finite element approach. Parameters: - Numerical studies are carried out for a fixed Prandtl number (Pr = 0.71) and fixed geometry of the rotating blade while varying the other parameters i.e. Rayleigh number, Reynolds number and Biot number. This dynamic boundary problem encompasses a wide range of parameters i.e. (100 <= Re <= 10(3)), (10(3)<= Bi <= 10(4)) and (10(4) <= Ra <= 10(7)) to evaluate the thermodynamic behavior of the thermo-fluid system. External flow condition is taken into consideration in terms of Biot number. Effects of these parameters are visualized through streamlines, heatlines, spatially average Nusselt number evaluated on the heated surface and system effectiveness. Objective: - Present computational study focuses on the transient analysis of the conjugate forced convection flow and heat transfer characteristics in a hexagonal, air filled cavity. This cavity is equipped with a floor heater of constant heat flux under the rotational influence of an adiabatic flow modulator. And the blade is placed in the central position of the cavity which is rotating in the clockwise direction. Also, the whole computational domain is composed of four different domains, one convective domain and three solid domains. The solid domains are made of brick and glass as per their practical aspects. Findings: - A Fast Fourier Transform (FFT) analysis is presented to comprehend the thermo-oscillating system response. FFT plots indicate that for all of the cases the fundamental frequency of the system response conforms to the blade frequency. Moreover, present numerical results show that the heat transfer effectiveness has an inverse relationship with the Biot and Rayleigh numbers while improves significantly with the increase of Reynolds number and reaches a critical state for Re-cr = 650. Higher Reynolds number also attenuates the degree of power spectrum. Conclusion: - To attain a higher heat transfer effectiveness the thermo - fluid system should be operated at low Rayleigh number with higher Reynolds number. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Conjugate forced convection transient flow and heat transfer analysis in a hexagonal, partitioned, air filled cavity with dynamic modulator
    Ikram, Maruf Md.
    Saha, Goutam
    Saha, Suvash C.
    International Journal of Heat and Mass Transfer, 2021, 167
  • [2] CONJUGATE NATURAL-CONVECTION HEAT-TRANSFER IN AN AIR-FILLED RECTANGULAR CAVITY
    HO, CJ
    YIH, YL
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1987, 14 (01) : 91 - 100
  • [3] Unsteady conjugate heat transfer characteristics in hexagonal cavity equipped with a multi-blade dynamic modulator
    Ikram, Maruf Md
    Saha, Goutam
    Saha, Suvash C.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 200
  • [4] Conjugate natural convection heat transfer in a partitioned differentially-heated square cavity
    Khatamifar, Mehdi
    Lin, Wenxian
    Armfield, S. W.
    Holmes, David
    Iirkpatrick, M. P.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 81 : 92 - 103
  • [5] Conjugate heat transfer analysis of turbulent forced convection of moving plate in a channel flow
    Satish, N.
    Venkatasubbaiah, K.
    APPLIED THERMAL ENGINEERING, 2016, 100 : 987 - 998
  • [6] Transient heat transfer for forced convection flow of helium gas
    Liu, QS
    Fukuda, K
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2002, 45 (03) : 559 - 564
  • [7] Steady and Transient State Analyses on Conjugate Laminar Forced Convection Heat Transfer
    Afzal, Asif
    Samee, A. D. Mohammed
    Razak, R. K. Abdul
    Ramis, M. K.
    ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2020, 27 (01) : 135 - 170
  • [8] Steady and Transient State Analyses on Conjugate Laminar Forced Convection Heat Transfer
    Asif Afzal
    A. D. Mohammed Samee
    R. K. Abdul Razak
    M. K. Ramis
    Archives of Computational Methods in Engineering, 2020, 27 : 135 - 170
  • [9] Transient natural convection flows and heat transfer in a thermally stratified air-filled trapezoidal cavity
    Rahaman, Md. Mahafujur
    Bhowmick, Sidhartha
    Ghosh, Bishnu Pada
    Xu, Feng
    Mondal, Rabindra Nath
    Saha, Suvash C.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 47
  • [10] Conjugate heat and mass transfer by natural convection in a square cavity filled with a mixture of Air-CO2
    Serrano-Arellano, J.
    Gijon-Rivera, M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 70 : 103 - 113