Polymer microcantilever biochemical sensors with integrated polymer composites for electrical detection

被引:63
|
作者
Seena, V [1 ]
Rajorya, Anukool [1 ]
Pant, Prita [2 ]
Mukherji, Soumyo [3 ]
Rao, V. Ramgopal [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Ctr Excellence Nanoelect, Bombay 400076, Maharashtra, India
[2] Indian Inst Technol, Dept Met Engn & Mat Sci, Bombay 400076, Maharashtra, India
[3] Indian Inst Technol, Sch Biosci & Engn, Bombay 400076, Maharashtra, India
关键词
Biosensing; Microcantilever; Gauge factor; Young's modulus; Piezoresistor; Polymer; SU-8; Polymer carbon black composite; SU-8; IMMOBILIZATION;
D O I
10.1016/j.solidstatesciences.2009.06.009
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Micro fabricated sensors based on nanomechanical motion with piezoresistive electrical readout have become a promising biochemical sensing tool. The conventional microcantilever materials are mostly silicon-based. The sensitivity of the sensor depends on Young's modulus of the structural material, thickness of the cantilever as well as on the gauge factor of the piezoresistor. UV patternable polymers such as SU-8 have a very low Young's modulus compared to the silicon-based materials. Polymer cantilevers with a piezoresistive material having a large gauge factor and a lower Young's modulus are therefore highly suited for sensing applications. In this work, a spin coatable and photopatternable mixture of carbon black (CB) and SU-8, with proper dispersion characteristics, has been demonstrated as a piezoresistive thin film for polymer microcantilevers. Results on percolation experiments of SU-8/CB composite and fabrication of piezoresistive SU-8 microcantilevers using this composite are presented. With our controlled dispersion experiments, we could get a uniform piezoresistive thin film of thickness less than 1.2 mu m and resistivity of 2.7 Omega cm using 10 wt% of CB in SU-8. The overall thickness of the SU-8/composite/SU-8 is approximately 3 pm. We further present results on the electromechanical characterization and biofunctionalization of the cantilever structures for biochemical sensing applications. These cantilevers show a deflection sensitivity of 0.55 ppm/nm. Since the surface stress sensitivity is 4.1 x 10(-3) [N/m](-1), these cantilevers can well be used for detection of protein markers for pathological applications. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1606 / 1611
页数:6
相关论文
共 50 条
  • [1] Microcantilever sensors for biochemical detection
    Jingjing Wang
    Baozheng Xu
    Yinfang Zhu
    Junyuan Zhao
    Journal of Semiconductors, 2023, 44 (02) : 76 - 86
  • [2] Microcantilever sensors for biochemical detection
    Jingjing Wang
    Baozheng Xu
    Yinfang Zhu
    Junyuan Zhao
    Journal of Semiconductors, 2023, (02) : 76 - 86
  • [3] Microcantilever sensors for biochemical detection
    Wang, Jingjing
    Xu, Baozheng
    Zhu, Yinfang
    Zhao, Junyuan
    JOURNAL OF SEMICONDUCTORS, 2023, 44 (02)
  • [4] The mechanics of polymer swelling on microcantilever sensors
    Privorotskaya, Natalya L.
    King, William P.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2009, 15 (02): : 333 - 340
  • [5] The mechanics of polymer swelling on microcantilever sensors
    Natalya L. Privorotskaya
    William P. King
    Microsystem Technologies, 2009, 15 : 333 - 340
  • [6] FABRICATION AND CHARACTERIZATION OF NOVEL POLYMER COMPOSITE MICROCANTILEVER SENSORS FOR EXPLOSIVE DETECTION
    Seena, V
    Rajoriya, Anukool
    Fernandes, Avil
    Dhale, Karuna
    Pant, Prita
    Mukherji, Soumyo
    Rao, V. Ramgopal
    MEMS 2010: 23RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2010, : 851 - 854
  • [7] Monitoring swelling and deswelling of thin polymer films by microcantilever sensors
    Del Rey, Mercedes
    Da Silva, Rubens A.
    Meneses, David
    Petri, Denise F.S.
    Tamayo, Javier
    Calleja, Montserrat
    Kosaka, Priscila M.
    Sensors and Actuators, B: Chemical, 2014, 204 : 602 - 610
  • [8] High Precision Electrohydrodynamic Printing of Polymer Onto Microcantilever Sensors
    Pikul, James H.
    Graf, Phil
    Mishra, Sandipan
    Barton, Kira
    Kim, Yong-Kwan
    Rogers, John A.
    Alleyne, Andrew
    Ferreira, Placid M.
    King, William P.
    IEEE SENSORS JOURNAL, 2011, 11 (10) : 2246 - 2253
  • [9] Monitoring swelling and deswelling of thin polymer films by microcantilever sensors
    del Rey, Mercedes
    da Silva, Rubens A.
    Meneses, David
    Petri, Denise F. S.
    Tamayo, Javier
    Calleja, Montserrat
    Kosaka, Priscila M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 602 - 610
  • [10] Monitoring swelling and deswelling of thin polymer films by microcantilever sensors
    Petri, Denise F.S., 1600, Elsevier B.V., Netherlands (204):