Evolving the surveillance and workup of heart transplant rejection: A real-world analysis of the Molecular Microscope Diagnostic System

被引:9
|
作者
Alam, Amit [1 ,2 ]
Van Zyl, Johanna [1 ,2 ]
Milligan, Gregory Paul [1 ]
McKean, Staci Michelle [1 ]
Patel, Raksha [1 ]
Hall, Shelley Anne [1 ,2 ]
机构
[1] Baylor Univ, Div Adv Heart Failure, Med Ctr, 3410 Worth St,Suite 250, Dallas, TX 75246 USA
[2] Texas A&M Univ, Coll Med, Bryan, TX USA
关键词
clinical research/practice; heart transplantation/cardiology; molecular biology: mRNA/mRNA expression; microarray/gene array; rejection; rejection: antibody-mediated (ABMR); T cell mediated (TCMR);
D O I
10.1111/ajt.17087
中图分类号
R61 [外科手术学];
学科分类号
摘要
The Molecular Microscope Diagnostic System (MMDx) analyzes RNA transcripts of transplanted heart tissue to differentiate among T cell-mediated rejection (TCMR), antibody-mediated rejection (AMR), injury, and healthy tissue. However, little is known about its performance in relation to other modalities in a real-world heart transplant population. We evaluated whether MMDx performs in agreement with other validated modalities. Two hundred and twenty-eight corresponding endomyocardial biopsies (EMBx) and MMDx specimens from 135 adult heart transplant patients were retrospectively reviewed with correlating donor-derived cell-free DNA (dd-cfDNA). Rejection was classified on EMBx in 29 specimens (TCMR >= 2R and/or AMR >= 1), on MMDx in 56 specimens, and in 74 values with dd-cfDNA >= 0.20%. Despite moderate agreement between EMBx and MMDx (84% agreement, Cohen's kappa, 0.48, p < .001), systematic differences were observed (McNemar's test, p < .001) where MMDx classified 32 of 37 discordant cases as rejection. MMDx and dd-cfDNA demonstrated slight agreement (72% agreement, Cohen's kappa, 0.39, p < .001); however, systematic differences were also apparent where MMDx classified 12 of 50 discordant specimens as rejection when dd-cfDNA was <0.20% (McNemar's test, p < .001). Our findings provide insight on the performance of MMDx relative to other modalities in a heart transplant cohort and have implications on the surveillance and workup of allograft rejection in heart transplantation.
引用
收藏
页码:2443 / 2450
页数:8
相关论文
共 50 条
  • [1] A Real-World Analysis with the Molecular Microscope Diagnostic System in Dual-Organ Transplant Recipients.
    Blair, J. M.
    Van Zyl, J.
    Milligan, G. P.
    McKean, S. M.
    Patel, R.
    Hall, S. A.
    Alam, A.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2022, 22 : 841 - 841
  • [2] The Molecular Microscope Diagnostic System: Assessment of Rejection and Injury in Heart Transplant Biopsies
    Halloran, Philip F.
    Madill-Thomsen, Katelynn S.
    TRANSPLANTATION, 2023, 107 (01) : 27 - 44
  • [3] Building a tissue-based molecular diagnostic system in heart transplant rejection: The heart Molecular Microscope Diagnostic (MMDx) System
    Halloran, Philip F.
    Potena, Luciano
    Van Huyen, Jean-Paul Duong
    Bruneval, Patrick
    Leone, Ornella
    Kim, Daniel H.
    Jouven, Xavier
    Reeve, Jeff
    Loupy, Alexandre
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (11): : 1192 - 1200
  • [4] Diagnostic Performance of Molecular Microscope Diagnostic System in Addition to Cell Free DNA in Heart Transplant Rejection
    Ishaq, F.
    Fida, N.
    Nguyen, D. T.
    Edward, G. A.
    Guha, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S227 - S227
  • [5] Utility of Molecular Microscope Diagnostic System (mmdx) in Addition to Histopathology for Rejection Surveillance in Pediatric Heart Transplantation
    O'Halloran, C.
    Magnetta, D.
    Thrush, P.
    Monge, M.
    Joong, A.
    Tannous, P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S33 - S33
  • [6] A molecular microscope diagnostic system (MMDx) for heart transplant biopsies developed from the molecular phenotypes of rejection in kidney transplants.
    Halloran, Philip
    Kim, Daniel
    Loupy, Alexandre
    Jean-Paul Duong Van-Huyen
    Bruneval, Patrick
    Potena, Luciano
    Leone, Ornella
    Reeve, Jeff
    TRANSPLANTATION, 2016, 100 (07) : S294 - S295
  • [7] Added Value of Molecular Microscope Diagnostic System (mmdx) to Established Indicators of Heart Transplant Rejection: A Single Center Experience
    Cagliostro, M.
    Folch, A.
    Ali, S.
    Lala-Trindade, A.
    Moss, N.
    Parikh, A.
    Contreras, J.
    Mitter, S.
    Trivieri, M.
    Gidea, C.
    Mancini, D.
    Barghash, M. H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S436 - S436
  • [8] Evolving a real-world vehicle warning system
    Kohl, Nate
    Stanley, Kenneth
    Miikkulainen, Risto
    Samples, Michael
    Sherony, Rini
    GECCO 2006: GENETIC AND EVOLUTIONARY COMPUTATION CONFERENCE, VOL 1 AND 2, 2006, : 1681 - +
  • [9] Progress in Noninvasive Surveillance for Acute Rejection in Pediatric Heart Transplant Recipients: A Real-World Analysis of Donor-Derived Cell-Free DNA-Based Surveillance Protocol
    Akabas, Leor
    Bravo, Stephen A.
    Zhang, Yun
    Simonelli, Anna
    Zuckerman, Warren A.
    Richmond, Marc E.
    Lytrivi, Irene D.
    CLINICAL TRANSPLANTATION, 2024, 38 (10)
  • [10] Commentary on development of the "molecular microscope (MMDX)" assay for heart transplant biopsy rejection surveillance: SCVP journal club
    Miller, Dylan V.
    CARDIOVASCULAR PATHOLOGY, 2022, 60