Results of an innovative method of intramedullary fixation for displaced 4-part fractures of the proximal humerus in patients younger than 70 years

被引:1
|
作者
Desai, Sanjay [1 ]
Jain, Rohit [1 ]
Singh, Vishwajeet [1 ]
机构
[1] Bhatia Hosp, Dept Orthopaed, Mumbai, Maharashtra, India
关键词
Displaced; four part; proximal; humerus; fractures; innovative; intramedullary; fixation; LOCKING PLATE FIXATION; OPEN REDUCTION; INTERNAL-FIXATION; HEMIARTHROPLASTY; EPIDEMIOLOGY; COMPLICATIONS; MALPOSITION; OUTCOMES; FAILURE;
D O I
10.1016/j.jse.2020.05.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The management of displaced 4-part fractures of proximal humerus is a challenge, as it is difficult to produce consistently good results with the current methods of fixation. Varus collapse of the head and eventual failure of plate fixation have been reported in up to 45% of cases. We present an innovative method of intramedullary fixation for displaced 4-part proximal humeral fractures. The aim of this study was to present the results of an intramedullary fixation device used for displaced 4-part proximal humeral fractures in patients younger than 70 years. Materials and methods: Fixation was performed with an intramedullary device in 30 patients with an average age of 56 years who had displaced 4-part proximal humeral fractures. The device consists of a circular staple that is impacted in the head and engages into the neck of an intramedullary uncemented stem. The stem has a sleeve that provides the ability to adjust the height and thereby facilitates accurate reduction of the tuberosity with ease. Fracture union was assessed with plain radiographs, and clinical outcomes were assessed using American Shoulder and Elbow Surgeons and Constant scores. Results: Union was achieved in 93.33% of patients and the mean American Shoulder and Elbow Surgeons and Constant scores were 75.2 and 73.97, respectively, at an average follow-up of 25.83 months. None of the patients had tuberosity avulsion, tuberosity nonunion, or resorption. However, 2 patients had humeral head nonunion and 2 had avascular necrosis. Revision surgery was performed in 2 patients (6.67%), because of avascular necrosis in 1 and nonunion in 1. Conclusion: In patients younger than 70 years with displaced 4-part proximal humeral fractures, the described intramedullary device provides a simple and reproducible method of internal fixation with predictable tuberosity union and shoulder function. (c) 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:331 / 339
页数:9
相关论文
共 50 条
  • [1] 3-Part And 4-Part Proximal Humerus Fractures: Is There A Role For Fixation
    Zubairu, M.
    Diack, M.
    Vukanic, D.
    Shannon, F.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2020, 189 (SUPPL 5) : S109 - S109
  • [2] 4-PART VALGUS IMPACTED FRACTURES OF THE PROXIMAL HUMERUS
    JAKOB, RP
    MINIACI, A
    ANSON, PS
    JABERG, H
    OSTERWALDER, A
    GANZ, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02): : 295 - 298
  • [3] Open Reduction and Internal Fixation of 3- and 4-Part Proximal Humerus Fractures
    Grilli, Stephanie
    Kazanjian, Jack E.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2016, 17 (03): : 116 - 121
  • [4] Intramedullary nailing of displaced four-part fractures of the proximal humerus
    Chouhan, Devendra Kumar
    Hooda, Aman
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (04): : 1130 - 1130
  • [5] Intramedullary nailing of displaced four-part fractures of the proximal humerus
    Kloub, Martin
    Holub, Karel
    Urban, Jiri
    Latal, Pavel
    Peml, Marek
    Krivohlavek, Martin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11): : 1978 - 1985
  • [6] Internal Fixation Versus Shoulder Hemiarthroplasty for Displaced 4-part Proximal Humeral Fractures in Elderly Patients
    Cai, Ming
    Tao, Kun
    Yang, Chunxi
    Li, Shaohua
    ORTHOPEDICS, 2012, 35 (09) : E1340 - E1346
  • [7] OPEN REDUCTION AND INTERNAL-FIXATION OF 3-PART AND 4-PART FRACTURES OF THE PROXIMAL HUMERUS
    ESSER, RD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (299) : 244 - 251
  • [8] Internal fixation of displaced fractures of the proximal humerus with a locked intramedullary blade nail
    Ahmed, Awaiz
    Middleton, Robert
    Pendse, Aniruddha
    Taylor, Geoffrey
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 1 - 8
  • [9] Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus A systematic review of benefits and harms
    Brorson, Stig
    Frich, Lars H.
    Winther, Annika
    Hrobjartsson, Asbjorn
    ACTA ORTHOPAEDICA, 2011, 82 (04) : 475 - 481
  • [10] Least possible fixation techniques of 4-part valgus impacted fractures of the proximal humerus: a systematic review
    Panagopoulos, Andreas
    Tatani, Irini
    Ntourantonis, Dimitrios
    Seferlis, Ioannis
    Kouzelis, Antonis
    Tyllianakis, Minos
    ORTHOPEDIC REVIEWS, 2016, 8 (01) : 16 - 22