TRAIN OF FOUR MONITORING DEVICE

被引:0
|
作者
Karapanagou, Anastasia [1 ]
Bergstrom, Nicholas R. [1 ]
Beauregard, Christopher [1 ]
Dillon, Kyler B. [1 ]
Skorinko, Jeanine L. M. [1 ]
Sabuncu, Ahmet Can [1 ]
Rosero, Eric B. [2 ]
机构
[1] Worcester Polytech Inst, Worcester, MA 01609 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Anesthesiol & Pain Management, Dallas, TX 75390 USA
关键词
Train of Four; monitoring; medical device; neuromuscular blockade;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Assessment of neuromuscular blockade during anesthesia is achieved using the Train of Four (TOF) monitoring technique. However, current devices are limited to conditions in which the hand can move freely during operation. The goal of this project was to design, prototype, and test a device which extends the TOF technique to conditions where movement is restricted. Interviews were conducted with stakeholders to better understand the need for this device and to get feedback on preliminary designs. The resulting device consists of a thumb-mounted balloon, which converts the force due to thumb twitches into pressure, which then acts as the physical analog to muscle response. This pressure is transduced and analyzed to produce a TOF count and TOF ratio. A prototype was constructed and tested on human subjects with different hand geometries.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A compressomyograph train of four monitoring device
    Guo, Shu
    Moore, Joe
    Moradi, Lee
    Rosero, Eric
    Sabuncu, Ahmet C.
    MEDICAL ENGINEERING & PHYSICS, 2024, 125
  • [2] Train of four monitoring
    Albetel-Biculescu, A.
    Grady, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2016, 185 : S135 - S135
  • [3] Train-of-Four monitoring: overestimation
    Han, Jeong Uk
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 60 (05) : 311 - 312
  • [4] Introduction of train condition monitoring device
    Honda, Yasuhiro
    Tsujio, Ryosuke
    Japanese Railway Engineering, 2020, 2020-January (207): : 5 - 7
  • [5] Optimised reversal without train-of-four monitoring versus reversal using quantitative train-of-four monitoring: An equivalence study
    Wardhana, Ardyan
    Kumiawaty, Juni
    Uyun, Yusmein
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (05) : 361 - 367
  • [6] Pediatric-compatible train-of-four monitoring
    Atlas, G
    Patel, A
    PEDIATRIC ANESTHESIA, 2005, 15 (08) : 707 - 708
  • [7] STIMULATION WITH SUBMAXIMAL CURRENT FOR TRAIN-OF-FOUR MONITORING
    BRULL, SJ
    EHRENWERTH, J
    SILVERMAN, DG
    ANESTHESIOLOGY, 1990, 72 (04) : 629 - 632
  • [8] Train-of-Four Test in Intraoperative Neurophysiologic Monitoring: Differences Between Hand and Foot Train-of-Four
    Gavrancic, Brane
    Lolis, Athena
    Beric, Aleksandar
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2014, 31 (06) : 575 - 579
  • [9] ANALYSIS OF OPERATION OF A VIGILANCE MONITORING DEVICE INSTALLED ON TRAIN ENGINES
    PETER, JH
    FRUHSTORFER, H
    LANGANKE, P
    MEINZER, K
    PFAFF, U
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1976, 365 : R26 - R26
  • [10] Design of Monitoring Device for Goods Train Based on Zigbee Technology
    Huo Chunbao
    Liu Chunling
    Zhang Caijuan
    MATERIALS AND MANUFACTURING, PTS 1 AND 2, 2011, 299-300 : 836 - 839