Two-phase natural circulation flow of air and water in a reactor cavity model under an external vessel cooling during a severe accident

被引:39
|
作者
Park, R. J. [1 ]
Ha, K. S. [1 ]
Kim, S. B. [1 ]
Kim, H. D. [1 ]
机构
[1] Korea Atom Energy Res Inst, Taejon 305353, South Korea
关键词
D O I
10.1016/j.nucengdes.2006.03.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
As a part of a study on a two-phase natural circulation flow between the outer reactor vessel and the insulation material in the reactor cavity under an external reactor vessel cooling of the Advanced Power Reactor (APR) 1400, a Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow-HALF scale (HERMES-HALF) experiment has been performed by using the non-heating method of an air injection. This large-scale experiment uses a half-height and half-sector model of the APR1400. This experiment has been analyzed to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5/MOD3 results have shown that the water circulation mass flow rate is very similar to the experimental results of the HERMES-HALF, in general. Increases in the water inlet area and the water level in the reactor cavity lead to an increase in the water circulation mass flow rate. The effects of an air injection mass flow rate and the water outlet area on the water circulation mass flow rate are dependent on the water inlet area size. As the water outlet moves to a lower position, the water circulation mass flow rate increases slowly. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2424 / 2430
页数:7
相关论文
共 50 条
  • [1] Loop analysis of a natural circulation two-phase flow under an external reactor vessel cooling
    Korea Atomic Energy Research Institute, P.O. Box 105, Yuseong, Daejeon 305-353, Korea, Republic of
    Int. Commun. Heat Mass Transf., 2008, 8 (1001-1006):
  • [2] Analytical evaluation of two-phase natural circulation flow characteristics under external reactor vessel cooling
    Park, Jong Woon
    ANNALS OF NUCLEAR ENERGY, 2009, 36 (11-12) : 1668 - 1675
  • [3] One-dimensional experiments of a natural circulation two-phase flow under an external reactor vessel cooling
    Kim, Jae Cheol
    Ha, Kwang Soon
    Park, Rae Joon
    Kim, Sang Baik
    Hong, Seong Wan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (06) : 716 - 722
  • [4] External cooling of a pressurized water reactor vessel during a severe accident
    Bereich Energieerzeugung , Siemens AG, Erlangen, Germany
    Kerntechnik, 2-3 (67-76):
  • [6] EXTERNAL COOLING OF A REACTOR VESSEL UNDER SEVERE ACCIDENT CONDITIONS
    HENRY, RE
    FAUSKE, HK
    NUCLEAR ENGINEERING AND DESIGN, 1993, 139 (01) : 31 - 43
  • [7] A study using RELAP5 on capability and instability of two-phase natural circulation flow under passive external reactor vessel cooling
    Zhao Guozhi
    Cao Xinrong
    Shi Xingwei
    ANNALS OF NUCLEAR ENERGY, 2013, 60 : 115 - 126
  • [8] Thermal behavior of the reactor vessel penetration under external vessel cooling during a severe accident
    Kang, KH
    Park, RJ
    Kim, JT
    Min, BT
    Lee, KY
    Kim, SB
    NUCLEAR TECHNOLOGY, 2004, 145 (01) : 57 - 66
  • [9] Probability analysis for external reactor vessel cooling effectiveness under severe accident
    Cao, Ke-Mei
    Xu, Yi-Quan
    Shi, Guo-Bao
    Cai, Jian-Ping
    Hedongli Gongcheng/Nuclear Power Engineering, 2009, 30 (01): : 1 - 4
  • [10] 1-D Two-phase Flow Investigation for External Reactor Vessel Cooling
    Kim, Jae-Cheol
    Ha, Kwang-Soon
    Park, Rae-Joon
    Cho, Young-Rho
    Kim, Sang-Baik
    Kim, Sin
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2007, 31 (05) : 482 - 490