General Distortion Correction Model of Omnidirectional Structured-Light Vision Measurement

被引:1
|
作者
Sun Junhua [1 ]
Liu Chang [1 ]
Zhang Zhou [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100191, Peoples R China
关键词
machine vision; distortion correction; refraction; omnidirectional structured-light vision;
D O I
10.3788/AOS201939.0215003
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the existing structured-light vision measurement systems, the camera and the projector arc installed inside a glass tube to cover the omnidirectional field of view, inevitably causing the refraction distortion. To address the distortion mentioned above, the refraction on two cylindrical interfaces is analyzed and the distortion caused by two non-coplanar refraction planes is investigated. A general distortion correction model of omnidirectional structured-light vision measurement is established. An aluminum tube with an internal diameter of 288.50 mm is measured by the omnidirectional structured-light vision measurement system and the internal diameter of this aluminum tube is calculated based on the proposed general distortion correction model. The experimental results indicate that the repeatability and precision reach 0.017 mm and 0.23 mm, respectively. The measurement system is stable and reliable, and the proposed general distortion correction model of omnidirectional structured-light vision measurement is highly accurate.
引用
收藏
页数:7
相关论文
共 20 条
  • [1] Laser Triangulation Profilometer for Inner Surface Inspection of 100 millimeters (4") Nominal Diameter
    Buschinelli, P.
    Pinto, T.
    Silva, F.
    Santos, J.
    Albertazzi, A.
    [J]. 3RD INTERNATIONAL CONGRESS ON MECHANICAL METROLOGY (CIMMEC2014), 2015, 648
  • [2] Buschinelli P D V, 2013, P SOC PHOTO-OPT INS, V8788
  • [3] Ding S W, 2017, Laser & Optoelectronics Progress, V54
  • [4] Accurate calibration of a multi-camera system based on flat refractive geometry
    Feng, Mingchi
    Huang, Shuai
    Wang, Jingshu
    Yang, Bin
    Zheng, Taixiong
    [J]. APPLIED OPTICS, 2017, 56 (35) : 9724 - 9734
  • [5] Feng Zhong-wei, 2009, Transactions of Beijing Institute of Technology, V29, P780
  • [6] Flexible method of refraction correction in vision measurement systems with multiple glass ports
    Gong, Zheng
    Liu, Zhen
    Zhang, Guangjun
    [J]. OPTICS EXPRESS, 2017, 25 (02): : 831 - 847
  • [7] Plate refractive camera model and its applications
    Huang, Longxiang
    Zhao, Xu
    Cai, Shen
    Liu, Yuncai
    [J]. JOURNAL OF ELECTRONIC IMAGING, 2017, 26 (02)
  • [8] A Novel Multi-Camera Calibration Method based on Flat Refractive Geometry
    Huang, S.
    Feng, M. C.
    Zheng, T. X.
    Li, F.
    Wang, J. Q.
    Xiao, L. F.
    [J]. INTERNATIONAL CONFERENCE ON ROBOTICS AND MECHANTRONICS (ICROM 2017), 2018, 320
  • [9] Applying PSD Analysis in Ring-Structured-Light 3D Measurement
    Leng, Huiwen
    Xu, Chunguang
    Feng, Zhongwei
    Xiao, Dingguo
    [J]. FIRST IITA INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2009, : 376 - 380
  • [10] Research on the calibration technology of an underwater camera based on equivalent focal length
    Li, Sheng-Qian
    Xie, Xiao-Peng
    Zhuang, Yong-Jun
    [J]. MEASUREMENT, 2018, 122 : 275 - 283