Can Ultrasound Accurately Assess Ischiofemoral Space Dimensions? A Validation Study

被引:14
|
作者
Finnoff, Jonathan T. [1 ]
Johnson, Adam C. [2 ]
Holtman, John H. [3 ]
机构
[1] Mayo Clin, Coll Med, Ctr Sports Med, Dept Phys Med & Rehabil, 600 Hennepin Ave,310, Minneapolis, MN 55403 USA
[2] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
[3] Mayo Clin, Coll Med, Dept Phys Med & Rehabil, Rochester, MN USA
关键词
QUADRATUS FEMORIS MUSCLE; TOTAL HIP-ARTHROPLASTY; IMPINGEMENT SYNDROME; LESSER TROCHANTER; PAIN; ABNORMALITIES; TEAR;
D O I
10.1016/j.pmrj.2016.06.024
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Ischiofemoral impingement is a potential cause of hip and buttock pain. It is evaluated commonly with magnetic resonance imaging (MRI). To our knowledge, no study previously has evaluated the ability of ultrasound to measure the ischiofemoral space (IFS) dimensions reliably. Objective: To determine whether ultrasound could accurately measure the IFS dimensions when compared with the gold standard imaging modality of MRI. Design: A methods comparison study. Setting: Sports medicine center within a tertiary-care institution. Participants: A total of 5 male and 5 female asymptomatic adult subjects (age mean = 29.2 years, range = 23-35 years; body mass index mean = 23.5, range = 19.5-26.6) were recruited to participate in the study. Methods: Subjects were secured in a prone position on a MRI table with their hips in a neutral position. Their IFS dimensions were then acquired in a randomized order using diagnostic ultrasound and MRI. Main Outcome Measurements: The main outcome measurements were the IFS dimensions acquired with ultrasound and MRI. Results: The mean IFS dimensions measured with ultrasound was 29.5 mm (standard deviation [SD] 4.99 mm, standard error mean 1.12 mm), whereas those obtained with MRI were 28.25 mm (SD 5.91 mm, standard error mean 1.32 mm). The mean difference between the ultrasound and MRI measurements was 1.25 mm, which was not statistically significant (SD 3.71 mm, standard error mean 3.71 mm, 95% confidence interval 0.49 mm to 2.98 mm, t(19) = 1.506, P =.15). The Bland-Altman analysis indicated that the 95% limits of agreement between the 2 measurement was 6.0 to 8.5 mm, indicating that there was no systematic bias between the ultrasound and MRI measurements. Conclusions: Our findings suggest that the IFS measurements obtained with ultrasound are very similar to those obtained with MRI. Therefore, when evaluating individuals with suspected ischiofemoral impingement, one could consider using ultrasound to measure their IFS dimensions.
引用
收藏
页码:392 / 397
页数:6
相关论文
共 50 条
  • [1] The accuracy assessment of ultrasound for the diagnosis of ischiofemoral space - A Validation Study
    Lu, Bo
    Deng, Heping
    Chen, Baicheng
    Zhao, Jian
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (04) : 605 - 614
  • [2] Ischiofemoral space dimensions for ischiofemoral impingement: is it different in children?
    Ten, Baris
    Beger, Orhan
    Balci, Yuksel
    Duce, Meltem Nass
    Beger, Burhan
    SKELETAL RADIOLOGY, 2022, 51 (03) : 625 - 635
  • [3] Ischiofemoral space dimensions for ischiofemoral impingement: is it different in children?
    Barış Ten
    Orhan Beger
    Yüksel Balcı
    Meltem Nass Duce
    Burhan Beger
    Skeletal Radiology, 2022, 51 : 625 - 635
  • [4] Can ultrasound accurately assess tumor thickness in carcinoma tongue to predict lymph node metastasis: A validation study
    Chauhan, T.
    Tankshali, R. A.
    ANNALS OF ONCOLOGY, 2017, 28
  • [5] Variability of the Ischiofemoral Space Relative to Femur Position: An Ultrasound Study
    Finnoff, Jonathan T.
    Bond, Jeffrey R.
    Collins, Mark S.
    Sellon, Jacob L.
    Hollman, John H.
    Wempe, Michael K.
    Smith, Jay
    PM&R, 2015, 7 (09) : 930 - 937
  • [6] Variability of ischiofemoral space dimensions with changes in hip flexion: an MRI study
    Adam C. Johnson
    John H. Hollman
    Benjamin M. Howe
    Jonathan T. Finnoff
    Skeletal Radiology, 2017, 46 : 59 - 64
  • [7] Variability of ischiofemoral space dimensions with changes in hip flexion: an MRI study
    Johnson, Adam C.
    Hollman, John H.
    Howe, Benjamin M.
    Finnoff, Jonathan T.
    SKELETAL RADIOLOGY, 2017, 46 (01) : 59 - 64
  • [8] Shoulder ultrasound: Can ultrasound accurately predict the type of surgery?
    McKie, SJ
    Beggs, I
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 41 - 41
  • [9] CAN STUDENTS ACCURATELY ASSESS THEIR OWN CLINICAL PERFORMANCE?
    Devanathan, D.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2017, 65 (04) : 823 - 823
  • [10] How accurately can we assess zoonotic risk?
    Wille, Michelle
    Geoghegan, Jemma L.
    Holmes, Edward C.
    PLOS BIOLOGY, 2021, 19 (04)