Gender Differences in Wear Rates for 28-vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty

被引:10
|
作者
Stambough, Jeffrey B. [1 ]
Pashos, Gail [1 ]
Wu, Ningying [2 ]
Haynes, Jacob A. [1 ]
Martell, John M. [3 ]
Clohisy, John C. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Orthopaed Surg, 660 South Euclid Ave,Campus Box 8233, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Div Biostat, St Louis, MO 63110 USA
[3] Univ Chicago Med & Biol Sci, Orthopaed Biomed Inst, Dept Orthopaed Surg & Rehabil Med, Chicago, IL USA
来源
JOURNAL OF ARTHROPLASTY | 2016年 / 31卷 / 04期
关键词
highly cross-linked polyethylene; wear; gender differences; Martell method; total hip arthroplasty outcomes; RANDOMIZED CONTROLLED-TRIAL; CONVENTIONAL POLYETHYLENE; UNITED-STATES; TOTAL JOINT; HARRIS HIP; REPLACEMENT; OSTEOARTHRITIS; BEARING; KNEE; PERFORMANCE;
D O I
10.1016/j.arth.2015.10.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We report on the midterm linear and volumetric wear of highly cross-linked polyethylene (HXLPE) and survivorship of 2 prospective young total hip arthroplasty (THA) cohorts that differed by the size of ceramic femoral head used: 28 vs 32 mm. Methods: We prospectively analyzed 220 consecutive primary THAs in patients aged <= 50 years who received a cementless THA with a ceramic femoral head on HXLPE liner (C-HXLPE). There were 101 patients (46%) with 28-mm heads and 119 patients (54%) who received 32-mm heads at a mean follow-up of 5.5 years (range, 60-109 months). Wear was calculated using Martell Software. Results: The 28-mm C-HXLPE cohort demonstrated average linear and volumetric wear of 0.020 mm/y (standard deviation [SD], 0.074; 95% CI, 0.003-0.037) and 18.775 mm(3)/y (SD, 21.743; 95% CI, 13.773-23.778) compared with 0.032 mm/y (SD, 0.087; 95% CI, 0.013-0.050]) and 29.847 mm(3)/y (SD, 35.441; 95% CI, 22.294-37.401) in the 32-mm C-HXLPE group. Subgroup analysis by gender and head size discovered significantly greater wear in females with 32-mm heads compared with 28-mm heads in both linear (0.01, 95% CI = -0.014 to 0.033 vs 0.048, 95% CI = 0.022-0.074 mm/y, P = .004) and volumetric wear (14.11, 95% CI = 8.957-19.271] vs 29.71, 95% CI = 17.584-41.840] mm(3)/y, P = .009). We found a 96% (95% CI = 92.30%-97.94%]) survivorship by Kaplan-Meier analysis at minimum 5 years with no failures because of osteolysis. Conclusions: Ceramic on HXLPE demonstrates extremely low wear properties in young patients at midterm follow-up. We identified a gender-dependent difference in wear based on head size, with 32-mm heads being associated with increased wear in females. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:899 / 905
页数:7
相关论文
共 50 条
  • [1] Large Femoral Heads in Total Hip Arthroplasty With Vitamin E Highly Cross-Linked Polyethylene: Head Penetration Rates Compared to Highly Cross-Linked Polyethylene
    Nielson, Trent
    Owens, Garrett
    Miller, Brandon
    Meneghini, Ethan
    Deckard, Evan R.
    Meneghini, R. Michael
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S685 - S691
  • [2] Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads
    Kanto Mouri
    Tatsuro Karita
    Journal of Artificial Organs, 2021, 24 : 234 - 242
  • [3] Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty
    Buckner, Brandt C.
    Urban, Nathanael D.
    Cahoy, Kevin M.
    Lyden, Elizabeth R.
    Deans, Christopher F.
    Garvin, Kevin L.
    BONE & JOINT JOURNAL, 2024, 106B (03): : 38 - 43
  • [4] Correction to: Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads
    Kanto Mouri
    Tatsuro Karita
    Journal of Artificial Organs, 2021, 24 : 243 - 243
  • [5] Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty With a 32-mm Cobalt-Chromium Head on Highly Cross-Linked Polyethylene and a Tapered, Fiber Metal Proximally Coated Femoral Stem
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF ARTHROPLASTY, 2021, 36 (02): : 647 - 652
  • [6] 10-Year Follow-Up Wear Analysis of Marathon Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Bookman, Jared S.
    Kaye, Ian D.
    Chen, Kevin K.
    Jaffe, Fredrick F.
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2587 - 2589
  • [7] Highly cross-linked polyethylene improves wear and mid-term failure rates for young total hip arthroplasty patients
    Keeney, James A.
    Martell, John M.
    Pashos, Gail
    Nelson, Christopher J.
    Maloney, William J.
    Clohisy, John C.
    HIP INTERNATIONAL, 2015, 25 (05) : 435 - 441
  • [8] 32-mm ceramic-on-ceramic total hip arthroplasty versus 28-mm ceramic bearings: 5-to 15-year follow-up study
    Higuchi, Yoshitoshi
    Seki, Taisuke
    Hasegawa, Yukiharu
    Takegami, Yasuhiko
    Morita, Daigo
    Ishiguro, Naoki
    HIP INTERNATIONAL, 2019, 29 (01) : 65 - 71
  • [9] Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36-vs 28-mm femoral heads
    Bragdon, Charles R.
    Greene, Meridith E.
    Freiberg, Andrew A.
    Harris, William H.
    Malchau, Henrik
    JOURNAL OF ARTHROPLASTY, 2007, 22 (06): : 125 - 129
  • [10] Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
    Deans, Christopher F.
    Buckner, Brandt C.
    Garvin, Kevin L.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)