High Histamine Control Concentration Leads to False Negative Allergy Skin Testing

被引:6
|
作者
Amirneni, Amulya [1 ]
Tversky, Jody [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Allergy & Clin Immunol, 5501 Hopkins Bayview Cir, Baltimore, MD 21224 USA
关键词
allergen; skin test; sensitivity; histamine; nasal allergen challenge; cat; ragweed;
D O I
10.1177/19458924211008685
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background Allergy skin test reliability depends on the reagents and controls selected. Histamine is used at 1 mg/ml and 6 mg/ml concentration but few studies address the rationale for selecting one versus the other and how this may impact diagnostic accuracy. Objective To determine the rate of false negative allergen skin tests responses between UniTest PC (using the 1 mg/mL histamine) and Quintip devices (using 6 mg/mL) for 4 common aeroallergens. Methods Subjects aged 18-65 with symptoms of allergy to cat and/or ragweed received skin testing with 4 aeroallergens (dust mite mix, timothy grass, ragweed, cat), histamine and control diluent. Those individuals who tested positive to cat or ragweed with one skin prick test (SPT) device but not the other then proceeded to nasal allergen challenge (NAC). The primary outcomes were the aeroallergen false negative rates and sensitivities of the skin test devices followed by nasal allergen (NAC). Results Twenty-five individuals were recruited and underwent a total of 300 SPTs. SPT to allergens (ragweed, dust mite, cat, and timothy grass) resulted in a statistically significant difference in wheal size among the two skin testing devices (p value <0.0001, 0.0001, 0.0006, and 0.0053 respectively). Six NAC procedures were performed to cat/ragweed and 5 of 6 (83% were positive). The overall allergen sensitivity rate for UniTest and Quintip were 97% and 78% respectively with most false negatives due to the use of 6 mg/ml histamine control reagent. Conclusion Our study shows that 6 mg/ml concentration of histamine control reagent may contribute to a false interpretation of aeroallergen skin prick test results.
引用
收藏
页码:854 / 860
页数:7
相关论文
共 50 条
  • [1] Factors associated with negative histamine control for penicillin allergy skin testing in the inpatient setting
    Geng, Bob
    Thakor, Ami
    Clayton, Elisabeth
    Finkas, Lindsay
    Riedl, Marc A.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2015, 115 (01) : 33 - 38
  • [2] HISTAMINE CONCENTRATION FOR SKIN TESTING
    MCCANN, ML
    ANNALS OF ALLERGY, 1994, 72 (01): : 51 - 51
  • [3] Intradermal testing after negative skin prick testing for patients with high suspicion of allergy
    Larrabee, Yuna C.
    Reisacher, William
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2015, 5 (06) : 547 - 550
  • [4] INFLUENCE OF THE HISTAMINE CONTROL ON SKIN REACTIVITY IN SKIN TESTING
    KOLLER, DY
    PIRKER, C
    JARISCH, R
    GOTZ, M
    ALLERGY, 1992, 47 (01) : 58 - 59
  • [5] Negative predictive value of skin testing for iodinated contrast media allergy
    Schrijvers, R.
    Ahmedali, Y.
    Chiriac, A. M.
    Demoly, P.
    ALLERGY, 2014, 69 : 260 - 261
  • [6] Intradermal Testing after Negative Skin Prick Testing For Patients with High Suspicion of Allergy (vol 5, pg 547, 2015)
    Larrabee, Yuna C.
    Reisacher, William
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2015, 5 (08) : 770 - 770
  • [7] FACTORS ASSOCIATED WITH NEGATIVE HISTAMINE RESPONSE FOR PENICILLINALLERGY SKIN TESTING IN THE INPATIENT SETTING
    Geng, B.
    Thakor, A.
    Finkas, L.
    Clayton, E.
    Vangala, S.
    Riedl, M.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2013, 111 (05) : A7 - A7
  • [8] NEGATIVE VACCINE ALLERGY SKIN TESTING STRONGLY PREDICTS FUTURE VACCINE TOLERANCE
    Elias, M. K.
    Rank, M. A.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2009, 103 (05) : A21 - A21
  • [9] Multiple Interventions Can Reduce Rates of False Penicillin ''Allergy'' Relabeling After Negative Testing
    Lutfeali, Shazia
    Kasra, Felicia
    Patel, Sheenal
    Joshi, Shyam
    Tarver, Scott A.
    Alvarez, Kristin
    Wei, Wenjing
    Khan, David A.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2019, 143 (02) : AB194 - AB194
  • [10] Pitfalls in drug allergy skin testing: false-positive reactions due to (hidden) additives
    Grims, RH
    Kranke, B
    Aberer, W
    CONTACT DERMATITIS, 2006, 54 (05) : 290 - 294