An analysis of the five-wire distribution system

被引:4
|
作者
Ward, DJ [1 ]
Buch, JF
Kulas, TM
Ros, WJ
机构
[1] Domin Virginia Power, Richmond, VA 23261 USA
[2] Madison Gas & Elect, Madison, WI 53701 USA
[3] Xcel Energy, Minneapolis, MN 55401 USA
[4] Gen Elect, Schenectady, NY 12345 USA
关键词
overhead distribution lines; power distribution;
D O I
10.1109/TPWRD.2002.804009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most power distribution systems in North America employ a four-wire multi-grounded neutral design. A five-wire distribution design has been proposed and studied in a project cosponsored by EPRI, the Empire State Electric Energy Research Corporation, the New York State Electric and Gas Corporation, and the New York State Energy Research and Development Authority. While summary information on the project claims five-wire distribution is a viable means of dealing with stray voltage, magnetic fields and high impedance faults, it does not appear that a balanced assessment has been presented. The purpose of this paper is to summarize the significant differences between the five-wire distribution system and the conventional four-wire multigrounded neutral system. Both four-wire and five-wire distribution are assumed to be multigrounded systems.
引用
收藏
页码:295 / 299
页数:5
相关论文
共 50 条
  • [1] Five-wire distribution system demonstration project
    Short, TA
    Stewart, JR
    Smith, DR
    O'Brien, J
    Hampton, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) : 649 - 654
  • [2] Five-wire resistive touchscreens
    Designfax Magazine, 1997, 19 (07):
  • [3] Compact Multifunctional Five-Wire Line-Based Microwave Sensor for Volumetric Characterization of Liquids
    Li, Zhen
    Wu, Changcheng
    Meng, Zhaozong
    Chen, Zhijun
    Fei, Fei
    IEEE SENSORS JOURNAL, 2022, 22 (07) : 6566 - 6575
  • [4] Simultaneous Determination of Levels and Complex Permittivities of Layered Liquids Using a Five-Wire Line-Based Microwave Sensor
    Li, Zhen
    Meng, Zhaozong
    Wu, Changcheng
    Fei, Fei
    Gibson, Andrew
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [5] A novel five-wire micro anemometer with 3D directionality for low speed air flow detection and acoustic particle velocity detecting capability
    Li, Zhe
    Chang, Wenhan
    Gao, Chengchen
    Hao, Yilong
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2018, 28 (04)
  • [6] Performance Analysis of DSTATCOM for Three Phase Three Wire Distribution System
    Aseem, K.
    Vanitha, V.
    Kumar, Selva S.
    INTERNATIONAL ENERGY JOURNAL, 2020, 20 : 271 - 278
  • [7] Performance analysis of DSTATCOM for three phase three wire distribution system
    Aseem, K.
    Vanitha, V.
    Selva Kumar, S.
    Aseem, K. (azieee@gmail.com), 1600, Regional Energy Resources Information Center (RERIC), Asian Institute of Technology (20): : 271 - 277
  • [8] DESIGNING A WIRE DISTRIBUTION-SYSTEM
    不详
    WIRE JOURNAL INTERNATIONAL, 1985, 18 (05): : 65 - 65
  • [9] Wire length distribution model for system LSI
    Kyogoku, T
    Inoue, J
    Nakashima, H
    Uezono, T
    Okada, K
    Masu, K
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2005, E88A (12): : 3445 - 3452
  • [10] WIRE-LESS DISTRIBUTION SYSTEM.
    Lewis, G.
    Electronic technology London, 1988, 22 (07): : 134 - 136