Assessment of left ventricular systolic function after VSD transcatheter device closure using speckle tracking echocardiography

被引:7
|
作者
Ali, Yasmin Abdelrazek [1 ]
Hassan, Maryam Araby [1 ]
EL Fiky, Azza Abdallah [1 ]
机构
[1] Ain Shams Univ, Cairo 11528, Egypt
来源
EGYPTIAN HEART JOURNAL | 2019年 / 71卷 / 01期
关键词
Ventricular septal defect; Speckle tracking; 2D strain; Transcatheter VSD closure; SEPTAL-DEFECTS; SURGICAL CLOSURE; STRAIN; CHILDREN; OCCLUDER; COIL;
D O I
10.1186/s43044-019-0001-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This is a case-control study conducted on 30 children, 15 with VSD who performed VSD transcatheter device closure (group A) and 15 controls of matching age and gender (group B), in the period between September 2015 and February 2018. We aimed to assess the global left ventricular (LV) systolic function by 2D speckle tracking before and after ventricular septal defect (VSD) transcatheter closure, in comparison to normal controls. All patients were subjected to full history taking; general and cardiac examination; ECG; CXR; full transthoracic echocardiographic examination, including VSD number, size, and site; LV dimensions and volumes; estimated pulmonary artery pressure; right ventricular size and function; left ventricular circumferential; and radial strain imaging by 2D speckle tracking. Patients who had ventricular septal defect closed were reassessed by transthoracic echocardiography after 3 months. Results: The study included 15 children with VSD: 3 males and 12 females; their age ranged from 2 to 13 years; all had subaortic VSD except for 1 who had apical muscular VSD: VSD size ranged from 3 to 8 mm; PFM coil was used to close defect in all patients except for 2 patients who had an Amplatzer duct occlude I (ADOI) device, and 1 patient needed an additional vascular plug after significant hemolysis. Pre-procedurally, group A had a significantly higher LVEDD, LVESD, and LVEDV than group B. Mean circumferential strain was significantly higher (more negative) in group A than that in group B either pre- or post-procedure. Post-procedurally, there was a significant decrease in circumferential strain (less negative) and a significant increase in radial strain (more positive). Conclusion: Following transcatheter VSD closure, there is a significant decrease in LV circumferential strain and a significant increase in LV radial strain, which conclude a decrease in LV volume overload with the improvement of its contractility.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Assessment of left ventricular systolic function after VSD transcatheter device closure using speckle tracking echocardiography
    Yasmin Abdelrazek Ali
    Maryam Araby Hassan
    Azza Abdallah EL Fiky
    The Egyptian Heart Journal, 71
  • [2] Assessment of Left Ventricular Systolic and Diastolic Function by 20 Speckle Tracking Echocardiography
    Zhou, Wei
    Mahajan, Amen
    CIRCULATION, 2008, 118 (18) : S605 - S606
  • [3] Assessment of the left ventricular systolic function in cardiac syndrome X using speckle tracking echocardiography
    Yagmur, Julide
    Acikgoz, Nusret
    Cansel, Mehmet
    Ermis, Necip
    Karakus, Yasin
    Kurtoglu, Ertugrul
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2016, 16 (06): : 419 - 423
  • [4] Assessment of left ventricular torsion using speckle tracking echocardiography
    Takeuchi M.
    Otani K.
    Otsuji Y.
    Lang R.M.
    Current Cardiovascular Imaging Reports, 2009, 2 (5) : 356 - 362
  • [5] Assessment of Left Ventricular Torsional Deformation Using Speckle-Tracking Imaging Before and After Transcatheter Device Closure of Atrial Septal Defect
    Dong, Lili
    Shu, Xianhong
    Zhou, Daxin
    Guan, Lihua
    Pan, Cuizhen
    Chen, Haiyan
    Kong, Dehong
    CIRCULATION, 2010, 122 (02) : E294 - E294
  • [6] ASSESSMENT OF LEFT VENTRICULAR FUNCTION USING SPECKLE TRACKING ECHOCARDIOGRAPHY IN PATIENTS WITH ESSENTIAL HYPERTENSION
    Mabrouk, Mohammad Shafiq
    Abdelhady, Yasser Ahmed
    Hassan, Mostafa Mohammad
    JOURNAL OF HYPERTENSION, 2023, 41 : E249 - E249
  • [7] SPECKLE TRACKING STRAIN ECHOCARDIOGRAPHY FOR RISK ASSESSMENT OF VENTRICULAR ARRHYTHMIAS AFTER LEFT VENTRICULAR ASSIST DEVICE PLACEMENT
    Akhabue, Ehimare
    Park, Chan Seok
    Pinney, Sean
    Anyanwu, Ani
    Chaudhry, Farooq
    Narula, Jagat
    Nair, Ajith
    Sengupta, Partho
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1138 - A1138
  • [8] Echocardiographic Assessment of Left Ventricular Systolic Function: An Overview of Contemporary Techniques, Including Speckle-Tracking Echocardiography
    Luis, Sushil A.
    Chan, Jonathan
    Pellikka, Patricia A.
    MAYO CLINIC PROCEEDINGS, 2019, 94 (01) : 125 - 138
  • [9] Preoperative and mid-term right ventricular systolic function assessment, at rest and during exercise, with speckle-tracking echocardiography after left ventricular assist device implantation
    Stapor, Maciej
    Pilat, Adam
    Misiuda, Agnieszka
    Gorkiewicz-Kot, Izabela
    Kaleta, Michal
    Kleczynski, Pawel
    Zmudka, Krzysztof
    Legutko, Jacek
    Kapelak, Boguslaw
    Wierzbicki, Karol
    Gackowski, Andrzej
    HELLENIC JOURNAL OF CARDIOLOGY, 2023, 76 : 31 - 39
  • [10] Global and regional systolic left ventricular function after arterial switch operation: a speckle tracking echocardiography study
    Di Salvo, G.
    Bulbul, Z.
    Moiduddin, N.
    Issa, Z.
    Al Oufi, S.
    Fayyadh, M.
    EUROPEAN HEART JOURNAL, 2015, 36 : 459 - 459