HLA-matched platelet transfusions are effective only in refractory patients with positive HLA antibody screening

被引:17
|
作者
Kreuger, Aukje L. [1 ,2 ]
Makelburg, Anja B. U. [3 ,4 ]
Somers, Judith A. E. [3 ,5 ]
Tomson, Bert [3 ]
van de Watering, Leo M. G. [3 ]
van der Bom, Johanna G. [1 ,2 ]
van Kraaij, Marian G. J. [1 ,3 ,6 ]
Weller, Claudia M. [3 ]
机构
[1] Sanquin Res, Ctr Clin Transfus Res, Amsterdam, Netherlands
[2] Leiden Univ, Med Ctr, Dept Clin Epidemiol, Leiden, Netherlands
[3] Sanquin Blood Bank, Unit Transfus Med, Amsterdam, Netherlands
[4] Sanquin Blood Bank, Unit Donor Affairs, Amsterdam, Netherlands
[5] Univ Med Ctr Groningen, Dept Hematol, Groningen, Netherlands
[6] Erasmus MC Daniel Den Hoed Canc Ctr, Dept Hematol, Rotterdam, Netherlands
关键词
THROMBOCYTOPENIA; MANAGEMENT; INCREMENTS;
D O I
10.1111/trf.15530
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Recipients of platelet transfusions with 1-hour corrected count increments (1hCCIs) of 7.5 or less on two subsequent platelet transfusions with random platelets may benefit from human leukocyte antigen (HLA)-matched platelet concentrates. We aimed to quantify the efficacy of HLA-matched platelets concentrates expressed in 1hCCIs. METHODS We performed a cohort study among consecutive refractory patients who received HLA-matched platelet concentrates in the Netherlands between 1994 and 2017. We performed mixed-model linear regression comparing 1hCCIs after HLA split-antigen-matched transfusions with 1hCCIs after HLA-mismatched transfusions, adjusted for within-patient correlations. A donor-to-patient match was categorized as a split-match if all donor HLA-A and -B antigens were present in the patient as well; that is, donor and patient were HLA identical or compatible. Subgroup analyses were performed for patients with positive or negative HLA antibody screens. Finally, the additional effect of ABO mismatches on 1hCCIs was investigated. RESULTS The 1hCCI after an HLA-matched transfusion was 14.09 (95% reference interval, 1.13-29.89). This was 1.94 (95% confidence interval [CI], 0.74-3.15) higher than 1hCCI after HLA-mismatched transfusions. In patients with negative HLA antibody screening tests, HLA matching did not affect 1hCCIs. Conditional on HLA matching, 1hCCIs decreased by 3.70 (95% CI, -5.22 to -2.18) with major ABO mismatches. CONCLUSION Matched platelet concentrates yielded maximal 1hCCIs, whereas mismatched transfusions still resulted in adequate increments. There is no indication for HLA-matched platelets in patients with negative antibody screens.
引用
收藏
页码:3303 / 3307
页数:5
相关论文
共 50 条
  • [1] SEROLOGICAL ANALYSIS OF REFRACTORINESS TO HLA-MATCHED PLATELET TRANSFUSIONS
    IKEDA, H
    MITANI, T
    HANDA, M
    FURIHATA, K
    SEKIGUCHI, S
    THROMBOSIS AND HAEMOSTASIS, 1989, 62 (01) : 150 - 150
  • [2] TRANSFUSION STRATEGY - USE OF HLA-MATCHED PLATELET TRANSFUSIONS FOR ALLOIMMUNIZED PATIENTS
    MENITOVE, JE
    DUQUESNOY, RJ
    AMERICAN JOURNAL OF MEDICAL TECHNOLOGY, 1981, 47 (02): : 114 - 120
  • [3] HLA-Matched Blood Transfusions?
    Scornik, Juan C.
    TRANSPLANTATION, 2012, 94 (11) : 1085 - 1085
  • [4] Predictive value of the MASPAT®-platelet crossmatch for HLA-matched platelet transfusions
    Sintnicolaas, K
    Van 't Veer, MB
    De Greef, GE
    Schipperus, MR
    Kappers-Klunne, MC
    Van Rhenen, DJ
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 214 - 214
  • [5] HLA-MATCHED PLATELET TRANSFUSIONS IN SEVERE APLASTIC-ANEMIA
    TOSATO, G
    APPELBAUM, FR
    DEISSEROTH, AB
    BLOOD, 1977, 50 (05) : 311 - 311
  • [6] Efficacy of HLA-matched platelet transfusions for patients with hypoproliferative thrombocytopenia: a systematic review
    Pavenski, Katerina
    Rebulla, Paolo
    Duquesnoy, Rene
    Saw, Chee Loong
    Slichter, Sherrill J.
    Tanael, Susano
    Shehata, Nadine
    TRANSFUSION, 2013, 53 (10) : 2230 - 2242
  • [7] Efficacy of HLA-Matched PLT Transfusions for Platelet Transfusion Refractoriness in HSCT Patients
    Seike, Keisuke
    Fujii, Nobuharu
    Fujii, Keiko
    Sando, Yasuhisa
    Nakamura, Makoto
    Saeki, Kyosuke
    Meguri, Yusuke
    Asada, Noboru
    Ennishi, Daisuke
    Nishimori, Hisakazu
    Matsuoka, Ken-Ichi
    Maeda, Yoshinobu
    BLOOD, 2018, 132
  • [8] Utilization of cross-matched or HLA-matched platelets for patients refractory to platelet transfusion
    Rioux-Masse, Benjamin
    Cohn, Claudia
    Lindgren, Bruce
    Pulkrabek, Shelly
    McCullough, Jeffrey
    TRANSFUSION, 2014, 54 (12) : 3080 - 3087
  • [9] The value of alloantibody detection in predicting response to HLA-matched platelet transfusions
    Levin, MD
    Kappers-Klunne, M
    Sintnicolaas, K
    van der Holt, B
    van Vliet, HHDM
    Löwenberg, B
    van't Veer, MB
    BRITISH JOURNAL OF HAEMATOLOGY, 2004, 124 (02) : 244 - 250
  • [10] Comparison of platelet antibody screen, crossmatching and HLA antibody testing in patients refractory to platelet transfusions
    Chapman, James M.
    Wendt, Linder
    Knudson, C. Michael
    TRANSFUSION AND APHERESIS SCIENCE, 2023, 62 (03)