Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer

被引:16
|
作者
Liu, Yi-Chi [1 ,2 ]
Chang, Hung-Ming [3 ]
Lin, Hsin-Hon [4 ,5 ,6 ]
Lu, Chia-Chun [7 ]
Lai, Lu-Han [8 ]
机构
[1] Natl Tsing Hua Univ, Inst Nucl Engn & Sci, Hsinchu 30015, Taiwan
[2] Wei Gong Mem Hosp, Dept Radiat Oncol, Miaoli 35148, Taiwan
[3] Wei Gong Mem Hosp, Dept Gen Surg, Miaoli 35159, Taiwan
[4] Chang Gung Univ, Med Phys Res Ctr, Inst Radiol Res, Chang Gung Mem Hosp, Taoyuan 33302, Taiwan
[5] Chang Gung Mem Hosp, Dept Radiat Oncol, Taoyuan 33305, Taiwan
[6] Keelung Chang Gung Mem Hosp, Dept Nucl Med, Keelung 20401, Taiwan
[7] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 30013, Taiwan
[8] Yuanpei Univ Med Technol, Dept Med Imaging & Radiol Technol, Hsinchu 30015, Taiwan
关键词
right breast cancer; volumetric modulated arc therapy; intensity-modulated radiotherapy; hybrid; 3D-CRT; IMRT; HISTOGRAM ANALYSIS; RADIATION-THERAPY; IMRT; RISK; LUNG; PNEUMONITIS; CHEMORADIATION; IRRADIATION; TRIAL;
D O I
10.3390/jcm9123884
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to compare different types of right breast cancer radiotherapy planning techniques and to estimate the whole-body effective doses and the critical organ absorbed doses. The three planning techniques are intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT; two methods) and hybrid 3D-CRT/IMRT (three-dimensional conformal radiotherapy/intensity-modulated radiotherapy). The VMAT technique includes two methods to deliver a dose: non-continuous partial arc and continuous partial arc. A thermoluminescent dosimeter (TLD) is placed in the RANDO phantom to estimate the organ absorbed dose. Each planning technique applies 50.4 Gy prescription dose and treats critical organs, including the lung and heart. Dose-volume histogram was used to show the planning target volume (V95%), homogeneity index (HI), conformity index (CI), and other optimized indices. The estimation of whole-body effective dose was based on the International Commission on Radiation Protection (ICRP) Publication 60 and 103. The results were as follows: Continuous partial arc and non-continuous partial arc showed the best CI and HI. The heart absorbed doses in the continuous partial arc and hybrid 3D-CRT/IMRT were 0.07 +/- 0.01% and 0% (V5% and V10%, respectively). The mean dose of the heart was lowest in hybrid 3D-CRT/IMRT (1.47 Gy +/- 0.02). The dose in the left contralateral lung (V5%) was lowest in continuous partial arc (0%). The right ipsilateral lung average dose and V20% are lowest in continuous partial arc. Hybrid 3D-CRT/IMRT has the lowest mean dose to contralateral breast (organs at risk). The whole-body effective doses for ICRP-60 and ICRP-103 were highest in continuous partial arc (2.01 Sv +/- 0.23 and 2.89 Sv +/- 0.15, respectively). In conclusion, the use of VMAT with continuous arc has a lower risk of radiation pneumonia, while hybrid 3D-CRT/IMRT attain lower secondary malignancy risk and cardiovascular complications.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [1] VOLUMETRIC MODULATED ARC THERAPY FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Palma, David
    Vollans, Emily
    James, Kerry
    Nakano, Sandy
    Moiseenko, Vitali
    Shaffer, Richard
    Mckenzie, Michael
    Morris, James
    Otto, Karl
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 996 - 1001
  • [2] Dosimetric Comparison of Three Different External Beam Partial Breast Irradiation Techniques: Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy
    Sun, T.
    Li, J.
    Xu, M.
    Liu, T.
    Lin, X.
    Zhang, G.
    MEDICAL PHYSICS, 2011, 38 (06) : 3682 - +
  • [3] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL PROTON RADIOTHERAPY, INTENSITY-MODULATED PROTON THERAPY, AND INTENSITY-MODULATED RADIOTHERAPY FOR TREATMENT OF PEDIATRIC CRANIOPHARYNGIOMAS
    Boehling, Nicholas S.
    Grosshans, David R.
    Bluett, Jaques B.
    Palmer, Matthew T.
    Song, Xiaofei
    Amos, Richard A.
    Sahoo, Narayan
    Meyer, Jeffrey J.
    Mahajan, Anita
    Woo, Shiao Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 643 - 652
  • [4] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [5] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Arc Therapy for Rectal Cancer
    Oskeroglu Kaplan, Sedenay
    Akboru, Halil
    Sarali, Yunus
    Altin, Suleyman
    Unsal, Mustafa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (02): : 59 - 65
  • [6] DOSIMETRIC COMPARISON OF VOLUMETRIC INTENSITY-MODULATED ARC (RAPIDARC) THERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D CONFORMAL RADIOTHERAPY FOR PRIMARY LIVER TUMOURS
    John, Jacob
    Sivasevan, Roshni
    Sudha, Arun Sankar
    Sivanandan, Choondal Devan
    Abdurahman, Sajeed
    Paramu, Raghukumar
    Sreedevi, Shaiju Vasudevan
    George, Preethi Sara
    Jayaprakash, Puthuveettil Govindan
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : E34 - E34
  • [7] Dosimetric analysis of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy-step and shoot, helical tomotherapy, and volumetric modulated arc therapy in prostate cancer radiotherapy
    Gozal, Fenny
    Gondhowiardjo, Soehartati Argadikoesoema
    Kodrat, Henry
    Wibowo, Wahyu Edy
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) : 893 - 900
  • [8] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy with Hybrid Intensity-Modulated Radiotherapy Techniques for Treatment of Locally Advanced Lung Cancer
    Suyunmez, Ozge
    Genc, Mine
    Ciftlikli, Ozlem Toykan
    Tuncel, Nina
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (03): : 239 - 245
  • [9] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [10] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for the Treatment of Multiple Intracranial Metastases
    Lin, X.
    Sun, T.
    Yin, Y.
    Liu, T.
    Lu, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3683 - +