Reliability of point-of-care prothrombin time testing in a community clinic: a randomized crossover comparison with hospital laboratory testing

被引:45
|
作者
Shiach, CR
Campbell, B
Poller, L
Keown, M
Chauhan, N
机构
[1] Manchester Royal Infirm, Dept Clin Haematol, Manchester M13 9WL, Lancs, England
[2] Univ Manchester, Sch Biol Sci, ECAA Cent Facil, Manchester, Lancs, England
关键词
point-of-care prothrombin time testing; warfarin; community medicine; ISI calibration;
D O I
10.1046/j.1365-2141.2002.03888.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The success in achieving therapeutic international normalized ratio (INR) targets in the control of warfarin using a whole-blood point-of-care testing (POCT) monitor (CoaguChek) in a community clinic was compared with hospital laboratory coagulometer prothrombin time (PT) testing in a randomized crossover study. Forty-six patients were randomized into two groups. At each visit, capillary blood was taken for the POCT monitor and venous blood for the laboratory coagulometer. In Group 1, for 6 months, dosage was based on the CoaguChek and for the second 6 months on the coagulometer. In the second group, the order was reversed. Dosages were determined using the DAWN AC computer programme. Success was assessed by the percentage of time patients were maintained within the INR targets. Agreement between laboratory and monitor INR, and patient satisfaction were also assessed. Results with the POCT monitor compared well with the hospital coagulometer. Time in INR target range between the groups was similar, with 60.9% on the POCT monitor and 59.3% with the laboratory coagulometer in Group 1 and in Group 2, respectively, 64.3% and 63.4% with no significant difference in mean INR. An INR above 4.0 gave some discrepant results. International Sensitivity Index calibrations of the two test systems indicated that the INRs were dependable. Patient questionnaires showed greater satisfaction with community POCT monitoring.
引用
收藏
页码:370 / 375
页数:6
相关论文
共 50 条
  • [1] The reliability of point-of-care (POC) prothrombin time testing -: A comparison of CoaguChek XS® INR measurements with hospital laboratory monitoring
    Ryan, Fiona
    O'Shea, Susan
    Ortel, Thomas L.
    Byrne, Stephen
    BLOOD, 2007, 110 (11) : 296A - 296A
  • [2] The reliability of point-of-care prothrombin time testing. A comparison of CoaguChek S® and XS® INR measurements with hospital laboratory monitoring
    Ryan, F.
    O'Shea, S.
    Byrne, S.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2010, 32 (01) : E26 - E33
  • [3] CoaguChek point-of-care testing prothrombin time monitors
    Braun, Sigmund Lorenz
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 128 (04) : 671 - 672
  • [4] Is perioperative point-of-care prothrombin time testing accurate compared to the standard laboratory test?
    Urwyler, Natalie
    Staub, Lukas R.
    Beran, Dominik
    Deplazes, Marcus
    Lord, Sarah J.
    Alberio, Lorenzo
    Theiler, Lorenz
    Greif, Robert
    THROMBOSIS AND HAEMOSTASIS, 2009, 102 (04) : 779 - 786
  • [5] COST-ANALYSIS OF POINT-OF-CARE LABORATORY TESTING IN A COMMUNITY-HOSPITAL
    NOSANCHUK, JS
    KEEFNER, R
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 103 (02) : 240 - 243
  • [6] COST-ANALYSIS OF POINT-OF-CARE LABORATORY TESTING IN A COMMUNITY-HOSPITAL
    LINDSLEY, J
    EBLE, JN
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 104 (01) : 107 - 107
  • [7] Fully printed prothrombin time sensor for point-of-care testing
    Williams, Nicholas X.
    Carroll, Brittani
    Noyce, Steven G.
    Hobbie, Hansel Alex
    Joh, Daniel Y.
    Rogers, Joseph G.
    Franklin, Aaron D.
    BIOSENSORS & BIOELECTRONICS, 2021, 172
  • [8] Point-of-care Laboratory Testing
    Gauglitz, Guenter
    Luppa, Peter B.
    CHEMIE IN UNSERER ZEIT, 2009, 43 (05) : 308 - 318
  • [9] Hospital-based point-of-care testing for prothrombin time: A survey of US hospitals.
    Stankovic, AK
    Shahangian, S
    Lubin, IM
    Handsfield, JH
    White, MD
    BLOOD, 2002, 100 (11) : 220A - 220A
  • [10] Comparison of a novel point-of-care coagulation testing device (Quantra™) with thromboelastography and laboratory testing
    Zghaibe, W.
    Klein, A.
    Besser, M.
    Munting, K.
    Blaudszun, G.
    ANAESTHESIA, 2018, 73 : 16 - 16