Application of GEANT4 to the Simulation of High Energy-Resolution Microcalorimeter Detectors

被引:4
|
作者
Hoover, Andrew S. [1 ]
Bacrania, Minesh K. [1 ]
Karpius, Pete J. [1 ]
Rabin, Michael W. [1 ]
Rudy, Cliff R. [1 ]
Vo, Duc T. [1 ]
Beall, James A. [2 ]
Doriese, William B. [2 ]
Hilton, Gene C. [2 ]
Horansky, Robert D. [2 ]
Irwin, Kent D. [2 ]
Ullom, Joel N. [2 ]
Vale, Leila R. [2 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] Natl Inst Stand & Technol, Boulder, CO 80305 USA
关键词
Gamma-ray; microcalorimeter; Monte Carlo; simulation; GAMMA-RAY SPECTROMETERS; ARRAYS;
D O I
10.1109/TNS.2009.2022160
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
GEANT4 is a versatile Monte Carlo code for simulating the interactions of radiation with matter. GEANT4 has proven to be an effective toolkit for the simulation of a wide variety of detectors. We are interested in the application of GEANT4 to a new type of sensor technology being developed for X-ray and gamma-ray measurements. Microcalorimeter detectors based on transition-edge sensors coupled to bulk absorbers are an emerging technology for hard X-ray and soft gamma-ray measurements with unprecedented energy resolution. In this work, we assess the ability of the GEANT4 electromagnetic physics package to reproduce measured microcalorimeter data. We also use the simulations to explore the design space of absorber materials and cryostat design.
引用
收藏
页码:2294 / 2298
页数:5
相关论文
共 50 条
  • [1] Geant4 simulation of high energy muon interactions
    Bogdanov, AG
    Burkhardt, H
    Ivanchenko, VN
    Kelner, SR
    Kokoulin, RP
    Maire, M
    Rybin, AM
    Urban, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2043 - 2047
  • [2] Geant4 Simulation of Energy Deposit in KASCADE-Grande Detectors
    Gherghel-Lascu, A.
    Sima, O.
    Brancus, I. M.
    Rebel, H.
    Haungs, A.
    Saftoiu, A.
    Toma, G.
    EXOTIC NUCLEI AND NUCLEAR/PARTICLE ASTROPHYSICS (IV): FROM NUCLEI TO STARS, 2012, 1498 : 329 - 333
  • [3] Simulation of LHCb RICH detectors using GEANT4
    Easo, S
    Belyaev, I
    Corti, G
    Jones, C
    Papanestis, J
    Pokorski, W
    Ranjard, F
    Robbe, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2182 - 2185
  • [4] Simulation of water Cerenkov detectors using GEANT4
    Anchordoqui, LA
    McCauley, TP
    Paul, T
    Reucroft, S
    Swain, JD
    Taylor, L
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2001, 97 : 196 - 198
  • [5] Application of GEANT4 simulation on calibration of HPGe detectors for cylindrical environmental samples
    Nikolic, J. D.
    Jokovic, D.
    Todorovic, D.
    Rajacic, M.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (02) : N47 - N55
  • [6] Simulation of LHCb RICH detectors using GEANT4
    Easo, S
    Belyaev, I
    Corti, G
    Jones, C
    Papanestis, A
    Pokorski, W
    Ranjard, F
    Robbe, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1665 - 1668
  • [7] Geant4 Simulation for Education in Medical Application
    Murakami, K.
    Amako, K.
    Jacquemier, J.
    Maire, M.
    Yoshida, H.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2444 - +
  • [8] The Geant4 Simulation Toolkit and Applications For the Geant4 Collaboration
    Apostolakis, John
    MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 73 - 92
  • [9] Geant4 simulation of a 3D high resolution gamma camera
    Akhdar, H.
    Kezzar, K.
    Gerl, J.
    Aksouh, F.
    Assemi, N.
    AlGhamdi, S.
    AlGarawi, M.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [10] Performance improvement of the high resolution neutron diffractometer at CAEP with Geant4 simulation
    Zhang, J.
    Xia, Y.
    Zhang, Y.
    Pang, B.
    Sun, G.
    Li, J.
    Huang, C.
    Wang, Y.
    Pan, J.
    Xie, C.
    JOURNAL OF INSTRUMENTATION, 2017, 12