Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events.

被引:2281
作者
Moss, Arthur J. [1 ]
Hall, W. Jackson [2 ]
Cannom, David S. [3 ]
Klein, Helmut
Brown, Mary W.
Daubert, James P. [4 ]
Estes, N. A. Mark, III [5 ]
Foster, Elyse [6 ]
Greenberg, Henry [7 ]
Higgins, Steven L. [8 ]
Pfeffer, Marc A. [9 ]
Solomon, Scott D. [9 ]
Wilber, David [10 ]
Zareba, Wojciech
机构
[1] Univ Rochester, Med Ctr, Heart Res Follow Up Program, Dept Med, Rochester, NY 14642 USA
[2] Univ Rochester, Med Ctr, Dept Biostat & Computat Biol, Rochester, NY 14642 USA
[3] Hosp Good Samaritan, Div Cardiol, Los Angeles, CA 90017 USA
[4] Duke Univ, Med Ctr, Dept Med, Durham, NC 27710 USA
[5] Tufts Univ New England Med Ctr, New England Cardiac Arrhythmia Ctr, Boston, MA USA
[6] Univ Calif San Francisco, Cardiol Unit, San Francisco, CA 94143 USA
[7] St Lukes Roosevelt Hosp, Cardiol Unit, New York, NY 10025 USA
[8] Scripps Mem Hosp, Dept Cardiol, La Jolla, CA USA
[9] Harvard Univ, Brigham & Womens Hosp, Sch Med, Div Cardiovasc, Boston, MA 02115 USA
[10] Loyola Univ, Med Ctr, Cardiovasc Inst, Chicago, IL 60611 USA
关键词
PROPHYLACTIC IMPLANTATION; DEFIBRILLATOR; TRIAL; GUIDELINES; COMMITTEE; CHAMBER;
D O I
10.1056/NEJMoa0906431
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This trial was designed to determine whether cardiac-resynchronization therapy (CRT) with biventricular pacing would reduce the risk of death or heart-failure events in patients with mild cardiac symptoms, a reduced ejection fraction, and a wide QRS complex. Methods: During a 4.5-year period, we enrolled and followed 1820 patients with ischemic or nonischemic cardiomyopathy, an ejection fraction of 30% or less, a QRS duration of 130 msec or more, and New York Heart Association class I or II symptoms. Patients were randomly assigned in a 3:2 ratio to receive CRT plus an implantable cardioverter-defibrillator (ICD) (1089 patients) or an ICD alone (731 patients). The primary end point was death from any cause or a nonfatal heart-failure event (whichever came first). Heart-failure events were diagnosed by physicians who were aware of the treatment assignments, but they were adjudicated by a committee that was unaware of assignments. Results: During an average follow-up of 2.4 years, the primary end point occurred in 187 of 1089 patients in the CRT-ICD group (17.2%) and 185 of 731 patients in the ICD-only group (25.3%) (hazard ratio in the CRT-ICD group, 0.66; 95% confidence interval [CI], 0.52 to 0.84; P=0.001). The benefit did not differ significantly between patients with ischemic cardiomyopathy and those with nonischemic cardiomyopathy. The superiority of CRT was driven by a 41% reduction in the risk of heart-failure events, a finding that was evident primarily in a prespecified subgroup of patients with a QRS duration of 150 msec or more. CRT was associated with a significant reduction in left ventricular volumes and improvement in the ejection fraction. There was no significant difference between the two groups in the overall risk of death, with a 3% annual mortality rate in each treatment group. Serious adverse events were infrequent in the two groups. Conclusions: CRT combined with ICD decreased the risk of heart-failure events in relatively asymptomatic patients with a low ejection fraction and wide QRS complex. (ClinicalTrials.gov number, NCT00180271.) N Engl J Med 2009;361:1329-38.
引用
收藏
页码:1329 / 1338
页数:10
相关论文
共 19 条
[1]  
Bardy GH, 2005, NEW ENGL J MED, V352, P2146
[2]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[3]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[4]  
COX DR, 1972, J R STAT SOC B, V187, P220
[5]   Syncope While Driving How Safe Is Safe? [J].
Curtis, Anne B. ;
Epstein, Andrew E. .
CIRCULATION, 2009, 120 (11) :921-923
[6]  
Epstein AE, 2008, CIRCULATION, V117, P2820, DOI 10.1161/CIRCUALTIONAHA.108.189741
[7]   Causes and consequences of heart failure after prophylactic implantation of a defibrillator in the multicenter automatic defibrillator implantation trial II [J].
Goldenberg, I ;
Moss, AJ ;
Hall, J ;
McNitt, S ;
Zareba, W ;
Andrews, ML ;
Cannom, DS .
CIRCULATION, 2006, 113 (24) :2810-2817
[8]   Sequential tests and estimators after overrunning based on maximum-likelihood ordering [J].
Hall, WJ ;
Liu, AY .
BIOMETRIKA, 2002, 89 (03) :699-707
[9]   CONFLICT-OF-INTEREST GUIDELINES FOR A MULTICENTER CLINICAL-TRIAL OF TREATMENT AFTER CORONARY-ARTERY BYPASS-GRAFT SURGERY [J].
HEALY, B ;
CAMPEAU, L ;
GRAY, R ;
HERD, JA ;
HOOGWERF, B ;
HUNNINGHAKE, D ;
KNATTERUD, G ;
STEWART, W ;
WHITE, C .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (14) :949-951
[10]  
Kalbfleisch JD., 2002, STAT ANAL FAILURE TI