Multifunctional microwell plate for on-chip cell and microbead-based bioassays

被引:6
|
作者
Yun, Kwang-Seok [1 ]
Lee, Dohoon [2 ]
Kim, Hak-Sung [3 ]
Yoon, Euisik [4 ]
机构
[1] Sogang Univ, Dept Elect Engn, Seoul 121742, South Korea
[2] Korea Inst Ind Technol, Green Proc R&D Dept, Ipjang Myeon 331825, Cheonan, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Biol Sci, Taejon 305701, South Korea
[4] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
关键词
Lab-on-a-chip; Bioassay; Microwell plate; Microbead; Cell chip; TOTAL ANALYSIS SYSTEMS; SINGLE CELLS; MICROFLUIDIC DEVICE; MANIPULATION; ASSAY; FABRICATION; SEPARATION; PLATFORM; PDMS;
D O I
10.1016/j.snb.2009.08.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on a multifunctional microwell plate developed for lab-on-a-chip applications, such as high-throughput cell assay, drug screening, and microbead-based analyses. The proposed device was designed to provide three consecutive functions: the autonomous capture of biomaterials into multiple microwells in a two-dimensional array; active physical sealing of the microwells for isolation; and specific chemical injection into each microwell. The device was implemented with microfabrication technology using polydimethylsiloxane (PDMS) structures on a silicon or glass substrate. The multiple functions of the microwell plate were successfully demonstrated in an experiment using microbeads. The parallel positioning of live cells (CHO DG44) in multiple microwell arrays was achieved, as well as the independent injection of foreign solution into a specific target cell. Also the proposed microwell plate was utilized to capture microbeads, for antibody injection into each microwell, for quantum dot (QD) injection, and for fluorescence detection for a feasible demonstration of a microbead-based assay. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [1] A CMOS magnetic microbead-based capacitive biosensor array with on-chip electromagnetic manipulation
    Chang, An-Yu
    Lu, Michael S-C.
    BIOSENSORS & BIOELECTRONICS, 2013, 45 : 6 - 12
  • [2] A fluorescent microbead-based microfluidic immunoassay chip for immune cell cytokine secretion quantification
    Cui, Xin
    Liu, Ya
    Hu, Dinglong
    Qian, Weiyi
    Tin, Chung
    Sun, Dong
    Chen, Weiqiang
    Lam, Raymond H. W.
    LAB ON A CHIP, 2018, 18 (03) : 522 - 531
  • [3] Magnetic Microbead-Based Herringbone Chip for Sensitive Detection of Human Immunodeficiency Virus
    Tang, Man
    Yuan, Xin-Yue
    Zhu, Kuan-Jie
    Sun, Wei
    Hong, Shao-Li
    Hu, Jiao
    Liu, Kan
    ANALYTICAL CHEMISTRY, 2024, 96 (04) : 1622 - 1629
  • [4] A microfluidic chip for measurement of biomolecules using a microbead-based quantum dot fluorescence assay
    Yun, Kwang-Seok
    Lee, Dohoon
    Kim, Hak-Sung
    Yoon, Euisik
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (12) : 3178 - 3183
  • [5] Microbead-based affinity chromatography chip using RNA aptamer modified with photocleavable linker
    Cho, S
    Lee, SH
    Chung, WJ
    Kim, YK
    Lee, YS
    Kim, BG
    ELECTROPHORESIS, 2004, 25 (21-22) : 3730 - 3739
  • [6] Gel pad array chip for high throughput and multi-analyte microbead-based immunoassays
    Zhu, Qingdi
    Trau, Dieter
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 370 - 378
  • [7] Nanoslit-concentration-chip integrated microbead-based protein assay system for sensitive and quantitative detection
    Koh, Yul
    Yang, Jin-Kyoung
    Oh, Min-Hye
    Kang, Homan
    Lee, Yoon-Sik
    Kim, Yong-Kweon
    RSC ADVANCES, 2017, 7 (47): : 29679 - 29685
  • [8] Titanium Microbead-Based Porous Implants: Bead Size Controls Cell Response and Host Integration
    Vrana, Nihal Engin
    Dupret-Bories, Agnes
    Schultz, Philippe
    Debry, Christian
    Vautier, Dominique
    Lavalle, Philippe
    ADVANCED HEALTHCARE MATERIALS, 2014, 3 (01) : 79 - 87
  • [9] On-chip multifunctional polarizer based on phase change material
    Long, Yuqian
    Fei, Yedeng
    Xu, Yin
    Ni, Yi
    APPLIED OPTICS, 2023, 62 (30) : 8025 - 8033
  • [10] High-throughput bio-molecule detection using microbead-based assay with quantum dot fluorescence in a microfluidic chip
    Yun, KS
    Lee, D
    Kim, MS
    Kim, HS
    Lee, GM
    Yoon, E
    Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 222 - 224