A microCT X-ray head model for spectra generation with Monte Carlo simulations

被引:11
|
作者
Taschereau, R. [1 ]
Chow, P. L. [1 ]
Cho, J. S. [1 ]
Chatziioannou, A. F. [1 ]
机构
[1] Univ Calif Los Angeles, Crump Inst Mol Imaging, Los Angeles, CA 90095 USA
基金
美国国家卫生研究院;
关键词
Monte Carlo; GEANT4; GATE; MicroCT; X-ray spectrum; TOOLKIT;
D O I
10.1016/j.nima.2006.08.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The X-ray spectrum from a small-animal computed tomography (CT) device directly influences the dose delivered to the animal as well as the image quality. For any given imaging task, the spectrum needs to be optimized. The aim of this study is to present a model of a small animal microCT X-ray source and to calculate practical spectra for different anode and filter combinations by using the Monte Carlo method. The GATE simulation package was used for this work. The X-ray source of the MicroCAT II scanner was modeled as a tungsten enclosure containing the X-ray tube with dielectric oil and a thin carbon exit window. The anode was a tungsten or molybdenum cylinder block tilted with respect to the electron-beam axis. Beam filtration was achieved through a disk of variable thickness and composition positioned at the exit window. Photon detection was performed with a thick (1 cm) cylindrical tungsten plate (20 cm diameter). Simulated spectra were compared with spectra measured with a CdTe detector for three beams: 50, 70 and 80 kVp with 2 mm of aluminum filtration. There was a reasonable agreement between measurements and calculations. Identified features of the measured spectra were: K absorption edges of Cd and Te (from the detector itself) and characteristic X-rays from Te (K alpha and K beta) and possibly Sb (K alpha). Discrepancies between simulations and measurements can be attributed to elements that have been left out of simulations, imperfect detector alignment, and uncertainty in elemental composition of simulated materials. The Monte Carlo method is a convenient and fast tool allowing the calculation of spectra possessing the essential features of real spectra. These and other spectra will be used in future work to study the influence of X-ray spectrum on dose and image quality for various X-ray CT system configurations. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:373 / 377
页数:5
相关论文
共 50 条
  • [1] Monte-Carlo simulations of X-ray binary spectra
    Leahy, DA
    12TH KINGSTON MEETING : COMPUTATIONAL ASTROPHYSICS, 1997, 123 : 109 - 111
  • [2] X-ray spectra by means of Monte Carlo simulations for imaging applications
    Tirao, G.
    Quintana, C.
    Malano, F.
    Valente, M.
    X-RAY SPECTROMETRY, 2010, 39 (06) : 376 - 383
  • [3] Monte Carlo simulations in X-ray imaging
    Giersch, Juergen
    Durst, Juergen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 300 - 305
  • [4] Optimization of x-ray spectra in digital mammography through Monte Carlo simulations
    Cunha, D. M.
    Tomal, A.
    Poletti, M. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07): : 1919 - 1935
  • [5] A bone composition model for Monte Carlo x-ray transport simulations
    Zhou, Hu
    Keall, Paul J.
    Graves, Edward E.
    MEDICAL PHYSICS, 2009, 36 (03) : 1008 - 1018
  • [6] Study on the characteristics of X-ray spectra in imaging diagnosis using Monte Carlo simulations
    Khanh Ai Tran
    Loan Thi Hong Truong
    Nhon Van Mai
    Phuong Nguyen Dang
    Dung Thi Thuy Vo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (07) : 1168 - 1174
  • [7] Interpretation of X-ray Absorption Spectra of As(III) in Solution Using Monte Carlo Simulations
    Canche-Tello, Jesus
    Cristina Vargas, M.
    Hernandez-Cobos, Jorge
    Ortega-Blake, Ivan
    Leclercq, Amelie
    Solari, Pierre Lorenzo
    Den Auwer, Christophe
    Mustre de Leon, Jose
    JOURNAL OF PHYSICAL CHEMISTRY A, 2014, 118 (46): : 10967 - 10973
  • [8] Study on the characteristics of X-ray spectra in imaging diagnosis using Monte Carlo simulations
    Khanh Ai Tran
    Loan Thi Hong Truong
    Nhon Van Mai
    Phuong Nguyen Dang
    Dung Thi Thuy Vo
    Journal of the Korean Physical Society, 2016, 69 : 1168 - 1174
  • [9] Mammography X-ray spectra simulated with Monte Carlo
    Vega-Carrillo, H. R.
    Gonzalez, J. Ramirez
    Manzanares-Acuna, E.
    Hernandez-Davila, V. M.
    Villasana, R. Hernandez
    Mercado, G. A.
    MEDICAL PHYSICS, 2008, 1032 : 208 - 211
  • [10] Monte Carlo simulation of x-ray spectra in mammography
    Ng, KP
    Kwok, CS
    Tang, FH
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05): : 1309 - 1318