Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating

被引:36
|
作者
Stufkens, Sjoerd A. [1 ]
Kloen, P. [1 ]
机构
[1] Acad Med Ctr, Dept Orthopaed Surg, NL-1100 DD Amsterdam, Netherlands
关键词
Clavicula; Non-union; Delayed union; LCP; Locking compression plating; Anteroinferior placement; FRACTURES; NONUNION; FIXATION;
D O I
10.1007/s00402-009-0864-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Pain and impaired shoulder function are the predominant symptoms of midshaft clavicle non-unions. Obtaining consolidation and improvement of shoulder function is often successfully achieved with osteosynthesis and bone grafting. Most data in the literature pertain to plate osteosynthesis, placing the plate on the subcutaneous superior aspect of the clavicle. Although union rates are generally high, most patients require hardware removal as the plate is prominent under the skin causing pain and cosmetic problems. In the current retrospective study, we followed a cohort of 21 consecutive cases (20 patients) with a midshaft clavicular delayed or non-union, treated with anteroinferior plating using a 3.5 mm locking compression plate (LCP) for a mean of 30 months. We operated on 10 males and 10 females with a mean age of 48.2 years (range 16-65). There was one early plate failure that needed revision. Two patients required hardware removal because of prominence of the plate. All but two patients were satisfied with the final cosmetic result. The average DASH score at follow up was 22.8. Anteroinferior plating with a 3.5 mm LCP is a reliable and reproducible treatment of midshaft clavicular delayed and non-union regarding consolidation, function, cosmesis and reduction of second surgery.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [1] Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating
    Sjoerd A. Stufkens
    P. Kloen
    Archives of Orthopaedic and Trauma Surgery, 2010, 130
  • [2] THE OPERATIVE TREATMENT OF MIDSHAFT CLAVICULAR NON-UNIONS
    MANSKE, DJ
    SZABO, RM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (09): : 1367 - 1371
  • [3] The Impact of Clavicular Length Restoration in the Treatment of Non-unions of Clavicular Midshaft and
    Hollo, David
    Kolling, Christoph
    Moro, Fabrizio
    Audige, Laurent
    Mueller, Andreas
    SWISS MEDICAL WEEKLY, 2019, 149 : 47S - 48S
  • [4] Anteroinferior plating of midshaft clavicular nonunions
    Kloen, P
    Sorkin, AT
    Rubel, IF
    Helfet, DL
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (06) : 425 - 430
  • [5] External fixators in the treatment of midshaft clavicle non-unions: A systematic review
    Barlow T.
    Upadhyay P.
    Barlow D.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 143 - 148
  • [6] COMPRESSION-STAPLE FIXATION FOR FRACTURES, NON-UNIONS, AND DELAYED UNIONS OF THE CARPAL SCAPHOID
    KORKALA, OL
    KUOKKANEN, HOM
    EEROLA, MS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (03): : 423 - 426
  • [7] Superior versus anteroinferior plating of displaced midshaft clavicular fracture in patients older than 60 years
    Lu, Minpeng
    Qiu, Hao
    Zhou, Xin
    Lee, Cody S.
    Jiang, Dianming
    Dong, Jing
    Quan, Zhengxue
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2017, 45 (02) : 753 - 761
  • [8] Comparison between locked intramedullary nailing and anatomical locking plating in the treatment of displaced clavicular midshaft fractures
    Zehir, Sinan
    Calbiyik, Murat
    Sahin, Ercan
    Ipek, Deniz
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2016, 50 (03) : 291 - 297
  • [9] THE TREATMENT OF NON-UNIONS WITH ELECTRICITY
    BRIGHTON, CT
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (05): : 847 - 851
  • [10] TREATMENT OF DIFFICULT NON-UNIONS OF LONG BONES WITH AO COMPRESSION APPARATUS
    ROSEN, H