Influence of hydraulic retention time on the operation of a submerged membrane sequencing batch reactor (SM-SBR) for the treatment of greywater

被引:30
|
作者
Scheumann, R. [1 ]
Kraume, M. [1 ]
机构
[1] Tech Univ Berlin, Chair Chem Engn, D-13355 Berlin, Germany
关键词
Hydraulic retention time; Greywater; Membrane bioreactor; SBR; BIOREACTOR TECHNOLOGY; WATER-TREATMENT;
D O I
10.1016/j.desal.2008.03.066
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study describes the experience received in operating ail SM-SBR under different hydraulic retention times for the treatment of synthetic greywater. The pilot scale SM-SBR with a working Volume of V-R = 500 L is operated with hydraulic retention times of 33, 24 and 12 h, and a volumetric exchange ratio of similar to 0.25. The removal of COD, ammonia, total nitrogen is investigated for the different set-ups. Despite the low COD in greywater, the treatment performance of the reactor is always sufficient to meet reuse guidelines. The biomass concentration increases slowly, although no excess sludge has been taken Out (except sampling). Therefore, the sludge age is assumed to be >360 d.
引用
收藏
页码:444 / 451
页数:8
相关论文
共 48 条
  • [1] Performance of a compact submerged membrane sequencing batch reactor (SM-SBR) for greywater treatment
    Kraume, Matthias
    Scheumann, Rene
    Baban, Ahmet
    El Hamouri, Bouchaib
    DESALINATION, 2010, 250 (03) : 1011 - 1013
  • [2] Greywater treatment in SBR-SND reactor-optimization of hydraulic retention time, volumetric exchange ratio and sludge retention time
    Priyanka, Kumari
    Behera, Manaswini
    Remya, Neelancherry
    ENVIRONMENTAL TECHNOLOGY, 2023, 44 (25) : 3791 - 3802
  • [3] Effect of the dilution rate and hydraulic retention time on the efficiency of the sequencing batch reactor (SBR) system with electroplating wastewater
    Sirianuntapiboon, Suntud
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2013, 1 (04): : 786 - 794
  • [4] Impact of hydraulic retention time on organic and nutrient removal in a membrane coupled sequencing batch reactor
    Xu, Shengnan
    Wu, Donglei
    Hu, Zhiqiang
    WATER RESEARCH, 2014, 55 : 12 - 20
  • [5] Methanosarcina domination in anaerobic sequencing batch reactor at short hydraulic retention time
    Ma, Jingwei
    Zhao, Baisuo
    Frear, Craig
    Zhao, Quanbao
    Yu, Liang
    Li, Xiujin
    Chen, Shulin
    BIORESOURCE TECHNOLOGY, 2013, 137 : 41 - 50
  • [6] Mechanism of membrane fouling in coke wastewater treatment by submerged membrane sequencing batch reactor
    Li, Chun-Jie
    Geng, Yan
    Zhou, Qi
    Gu, Guo-Wei
    Zhongguo Jishui Paishui/China Water & Wastewater, 2002, 18 (04):
  • [7] Impact of hydraulic retention time on swine wastewater treatment by aerobic granular sludge sequencing batch reactor
    Xiaochun Wang
    Ji Li
    Xiaolei Zhang
    Zhonglin Chen
    Jimin Shen
    Jing Kang
    Environmental Science and Pollution Research, 2021, 28 : 5927 - 5937
  • [8] Impact of hydraulic retention time on swine wastewater treatment by aerobic granular sludge sequencing batch reactor
    Wang, Xiaochun
    Li, Ji
    Zhang, Xiaolei
    Chen, Zhonglin
    Shen, Jimin
    Kang, Jing
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (05) : 5927 - 5937
  • [9] Optimizing sequencing batch reactor (SBR) reactor operation for treatment of dairy wastewater with aerobic granular sludge
    Wichern, M.
    Luebken, M.
    Horn, H.
    WATER SCIENCE AND TECHNOLOGY, 2008, 58 (06) : 1199 - 1206
  • [10] Effects of temperature and hydraulic retention time on anaerobic sequencing batch reactor treatment of low-strength wastewater
    Ndon, UJ
    Dague, RR
    WATER RESEARCH, 1997, 31 (10) : 2455 - 2466