Ablation of clinically relevant kidney tissue volumes by high-intensity focused ultrasound:: Preliminary results of standardized ex-vivo investigations

被引:5
|
作者
Haecker, Axel
Peters, Kristina
Knoll, Thomas
Marlinghaus, Ernst
Alken, Peter
Jenne, Juergen W.
Michel, Maurice Stephan
机构
[1] Univ Heidelberg, Dept Urol, Univ Hosp Mannheim, D-68135 Mannheim, Germany
[2] Stroz Med, Kreuzlingen, Switzerland
[3] German Canc Res Ctr, Clin Cooperat Unit, Heidelberg, Germany
关键词
D O I
10.1089/end.2006.20.930
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate strategies to achieve confluent kidney-tissue ablation by high-intensity focused ultrasound (HIFU). Materials and Methods: Our model of the perfused ex-vivo porcine kidney was used. Tissue ablation was performed with an experimental HIFU device (Storz Medical, Kreuzlingen, Switzerland). Lesion-to-lesion interaction was investigated by varying the lesion distance (5 to 2.5 mm), generator power (300, 280, and 260 W), cooling time (10, 20, and 30 seconds), and exposure time (4, 3, and 2 seconds). The lesion rows were analyzed grossly and by histologic examination (hematoxylin-eosin and nicotinamide adenine dinucleotide staining). Results: It was possible to achieve complete homogeneous ablation of a clinically relevant tissue volume but only by meticulous adjustment of the exposure parameters. Minimal changes in these parameters caused changes in lesion formation with holes within the lesions and lesion-to-lesion interaction. Conclusions: Our preliminary results show that when using this new device, HIFU can ablate a large tissue volume homogeneously in perfused ex-vivo porcine tissue under standardized conditions with meticulous adjustment of exposure parameters. Further investigations in vivo are necessary to test whether large tissue volumes can be ablated completely and reliably despite the influence of physiologic tissue and organ movement.
引用
收藏
页码:930 / 938
页数:9
相关论文
共 50 条
  • [1] Control parameters for high-intensity focused ultrasound (HIFU) for tissue ablation in the ex-vivo kidney
    Köhrmann, KU
    Michel, MS
    Steidler, A
    Marlinghaus, EH
    Kraut, O
    Alken, P
    AKTUELLE UROLOGIE, 2002, 33 (01) : 58 - 63
  • [2] High-intensity focused ultrasound for ex vivo kidney tissue ablation:: Influence of generator power and pulse duration
    Häcker, A
    Köhrmann, KU
    Knoll, T
    Langbein, S
    Steidler, A
    Kraut, O
    Marlinghaus, E
    Alken, P
    Michel, MS
    JOURNAL OF ENDOUROLOGY, 2004, 18 (09) : 917 - 924
  • [3] High-intensity focused ultrasound applied to the placenta using a toroidal transducer: a preliminary ex-vivo study
    Caloone, J.
    Huissoud, C.
    Vincenot, J.
    Kocot, A.
    Dehay, C.
    Chapelon, J. Y.
    Rudigoz, R. C.
    Melodelima, D.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (03) : 313 - 319
  • [4] HIGH-INTENSITY FOCUSED ULTRASOUND ABLATION OF EX VIVO BOVINE ACHILLES TENDON
    Muratore, Robert
    Akabas, Tal
    Muratore, Isabella B.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (12): : 2043 - 2050
  • [5] EX VIVO CHARACTERIZATION OF CANINE LIVER TISSUE VISCOELASTICITY AFTER HIGH-INTENSITY FOCUSED ULTRASOUND ABLATION
    Shahmirzadi, Danial
    Hou, Gary Y.
    Chen, Jiangang
    Konofagou, Elisa E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (02): : 341 - 350
  • [6] Influence of High-Intensity Focused Ultrasound (HIFU) Ablation on Arteries: Ex Vivo Studies
    Zhou, Yufeng
    Lim, Wei Chun Daniel
    MICROMACHINES, 2021, 12 (05)
  • [7] Multiple high-intensity focused ultrasound probes for kidney-tissue ablation
    Häcker, A
    Chauhan, S
    Peters, K
    Hildenbrand, R
    Marlinghaus, E
    Alken, P
    Michel, MS
    JOURNAL OF ENDOUROLOGY, 2005, 19 (08) : 1036 - 1040
  • [8] Re: High-intensity focused ultrasound applied to the placenta using a toroidal transducer: a preliminary ex-vivo study.
    Brezinka, C.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (03) : 248 - U134
  • [9] Ablation of tissue volumes using high intensity focused ultrasound
    Malcolm, AL
    terHaar, GR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (05): : 659 - 669
  • [10] Laparoscopic partial kidney ablation with high-intensity focused ultrasound
    Paterson, RF
    Shalhav, AL
    Lingeman, JE
    Sanghvi, NT
    Tavakkoli, J
    Rao, V
    JOURNAL OF UROLOGY, 2002, 167 (04): : 2 - 3