Characterization of Electric Fields Produced by Preliminary Breakdown Pulses Observed in Bogota, Colombia

被引:1
|
作者
Granados, C. A. [1 ]
Rojas, H. E. [2 ]
Rivera, C. A. [1 ]
Roman, F. J. [1 ]
机构
[1] Univ Nacl Colombia, Bogota Campus, Bogota, Colombia
[2] Univ Dist Francisco Jose de Caldas, Kra 7 40-53, Bogota, Colombia
关键词
Electric field; First return stroke; Individual pulses; Negative cloud-to-ground flashes; Preliminary breakdown pulses; Total pulse train duration; MALAYSIA;
D O I
10.1007/978-3-030-31676-1_115
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the characteristics of electric fields due to preliminary breakdown pulses (PBP) that precede the first return strokes (FRS) are presented. These pulses exist due to the electrical activity formed inside the clouds prior to the occurrence of the stepped leader. The electric field signatures were recorded in Bogota, Colombia with an altitude of 2550 m. For the measurement campaign, a broadband parallel-plate antenna system with a 500 ms full observation window and a pre-trigger of 250 ms were used. The measurements were carried out during two rainy seasons recording 180 waveforms. From recorded data, it was found that 37.5% of negative cloud-to-ground (CG) flashes exhibited PBP. With respect to the PBP trains a duration between 0.4 ms and 22.3 ms was observed. For the same temporal parameter, the arithmetic mean (AM) and the geometric mean (GM) were 4.7 ms and 3.1 ms, respectively. On the other hand, the GM of the time interval between the largest peak of the PBP train and the peak value of the FRS was 10.1 ms, while its AM was 27.9 ms. In addition, the GM of the ratio between the maximum value of the PBP train and its respective FRS was 0.51, with changes between 0.12 (minimum) and 2.1 (maximum). Finally, the number of individual pulses per train between 4 and 39.
引用
收藏
页码:1235 / 1243
页数:9
相关论文
共 15 条
  • [1] The Characterization of Electric Field Pulses Observed in the Preliminary Breakdown Processes of Normal and Inverted Intracloud Flashes
    Shi, Dongdong
    Zhang, Jinlai
    Gao, Panliang
    Zheng, Dong
    Qi, Qi
    Shao, Jie
    Kan, Shiqi
    Wang, Daohong
    Wu, Ting
    REMOTE SENSING, 2024, 16 (20)
  • [2] The Characterization of Electric Field Pulses Observed in the Preliminary Breakdown Processes of Normal and Inverted Intracloud Flashes
    Shi, Dongdong
    Zhang, Jinlai
    Gao, Panliang
    Zheng, Dong
    Qi, Qi
    Shao, Jie
    Kan, Shiqi
    Wang, Daohong
    Wu, Ting
    Remote Sensing, 16 (20):
  • [3] Characterization Preliminary Breakdown in the Measured Lightning Electric Fields
    Arshad, S. N. M.
    Izadi, M.
    Ab Kadir, M. Z. A.
    Abd Bari, M. A.
    Rameli, N.
    Rahim, N. Abdul
    Hamzah, M. N.
    2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO), 2014, : 435 - 438
  • [4] Observed preliminary breakdown pulses of intracloud discharges
    Emeraldi, Primas
    Hazmi, Ariadi
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 488 - 492
  • [5] A model of preliminary breakdown pulse peak currents and their relation to the observed electric field pulses
    Kaspar, Petr
    Santolik, Ondrej
    Kolmasova, Ivana
    Farges, Thomas
    GEOPHYSICAL RESEARCH LETTERS, 2017, 44 (01) : 596 - 603
  • [6] Comparison of preliminary breakdown pulses observed in Sweden and in Sri Lanka
    Gomes, C
    Cooray, V
    Jayaratne, C
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 1998, 60 (10) : 975 - 979
  • [7] Characterization of positive return strokes from a thundersto day observed in Bogota, Colombia
    Isabel Nino, Maria
    Enrique Rojas, Herbert
    Roman, Francisco
    2019 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XV SIPDA), 2019,
  • [8] Breakdown thresholds of picosecond optical pulses and nanosecond pulsed electric fields
    Coker, Zachary
    Noojin, Gary D.
    Ibey, Bennett L.
    Yakovlev, Vladislav
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXX, 2019, 10876
  • [9] Characterization of Measured Lightning Electric Fields Observed in Malaysia
    Arshad, S. N. M.
    Ab Kadir, M. Z. A.
    Izadi, M.
    Hamzah, M. N.
    Gomes, Chandima
    Jasni, J.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1058 - 1063
  • [10] Statistical analysis on preliminary breakdown pulses in negative cloud-to-ground flashes occurred in Colombia
    Granados, Camilo A.
    Rojas, Herbert E.
    Roman, Francisco J.
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,