Assessment of ocular blood flow in continuous-flow ventricular assist device by laser speckle flowgraphy

被引:1
|
作者
Shimamura, Junichi [1 ,2 ]
Nishinaka, Tomohiro [1 ]
Mizuno, Toshihide [1 ]
Tsukiya, Tomonori [1 ]
Inatomi, Ayako [1 ]
Kobayashi, Futoshi [1 ]
Katagiri, Nobumasa [1 ]
Takewa, Yoshiaki [1 ]
Nishimura, Takashi [1 ,3 ]
Ono, Minoru [2 ]
Tatsumi, Eisuke [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr Res Inst, Dept Artificial Organs, 6-1 Kishibe Shimmachi, Suita, Osaka 5648565, Japan
[2] Univ Tokyo, Dept Cardiac Surg, Tokyo, Japan
[3] Ehime Univ, Dept Cardiovasc & Thorac Surg, Matsuyama, Ehime, Japan
关键词
Peripheral circulation; Ventricular assist device; Laser speckle flowgraphy; Ocular blood flow; ROTATIONAL SPEED; PULSATILITY;
D O I
10.1007/s10047-021-01265-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although the influence of continuous-flow left ventricular assist device (CF-LVAD) support on peripheral circulation has been widely discussed, its monitoring modalities are limited. The aim of this study was to assess the peripheral circulation using the laser speckle flowgraph (LSFG) which can quantitatively measure the ocular blood flow. We implanted a centrifugal CF-LVAD (EVAHEART(R); Sun Medical Technology Research Corporation, Nagano, Japan) in five adult goats (body weight 44.5 +/- 2.9 kg) under general anesthesia. The waveform of the central retinal artery using the mean blur rate (MBR) for ocular blood velocity and fluctuations as a parameter of pulsatility were obtained before LVAD implantation and after LVAD full-bypass support. The MBR waveform and LSFG fluctuation data were compared with the waveform and pulsatility index of the external carotid artery using an ultrasonic flow meter to evaluate circulatory patterns at different levels. The MBR waveform pattern of the central retinal artery was pulsatile before LVAD implantation and less pulsatile under LVAD full bypass. The fluctuation was 14.7 +/- 1.86 before LVAD implantation and 3.85 +/- 0.61 under LVAD full bypass (p < 0.01), respectively. The fluctuations of LSFG showed a strong correlation with the pulsatility index of the external carotid artery meaning that similar changes in circulatory pattern were observed at two different levels. Measuring the ocular blood flow using LSFG has potential utility for the assessment of the status of the peripheral circulation and its pulsatility during CF-LVAD.
引用
收藏
页码:419 / 424
页数:6
相关论文
共 50 条
  • [1] Assessment of ocular blood flow in continuous-flow ventricular assist device by laser speckle flowgraphy
    Junichi Shimamura
    Tomohiro Nishinaka
    Toshihide Mizuno
    Tomonori Tsukiya
    Ayako Inatomi
    Futoshi Kobayashi
    Nobumasa Katagiri
    Yoshiaki Takewa
    Takashi Nishimura
    Minoru Ono
    Eisuke Tatsumi
    Journal of Artificial Organs, 2021, 24 : 419 - 424
  • [2] The assessment of ocular blood flow with laser speckle flowgraphy in healthy caucasian
    Wozniak, P. A.
    Luft, N.
    Aschinger, G.
    Fondi, K.
    Bata, A. M.
    Witkowska, K. J.
    Schmidl, D.
    Werkmeister, R. M.
    Bolz, M.
    Garhofer, G.
    Schmetterer, L.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [3] Use of laser speckle flowgraphy in ocular blood flow research
    Sugiyama, Tetsuya
    Araie, Makoto
    Riva, Charles E.
    Schmetterer, Leopold
    Orgul, Selim
    ACTA OPHTHALMOLOGICA, 2010, 88 (07) : 723 - 729
  • [4] Continuous-flow ventricular assist device - Reply
    Miller, Leslie W.
    Pagani, Francis D.
    NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22): : 2305 - 2306
  • [5] Continuous-Flow Left Ventricular Assist Device
    Landzaat, Lindy H.
    Sinclair, Christian T.
    Rosielle, Drew A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (12): : 1149 - 1149
  • [6] Blood flow in a continuous flow ventricular assist device
    Allaire, PE
    Wood, HG
    Awad, RS
    Olsen, DB
    ARTIFICIAL ORGANS, 1999, 23 (08) : 769 - 773
  • [7] Assessment of choroidal blood flow using laser speckle flowgraphy
    Calzetti, Giacomo
    Fondi, Klemens
    Bata, Ahmed M.
    Luft, Nikolaus
    Wozniak, Piotr A.
    Witkowska, Katarzyna J.
    Bolz, Matthias
    Popa-Cherecheanu, Alina
    Werkmeister, Rene M.
    Schmidl, Doreen
    Garhoefer, Gerhard
    Schmetterer, Leopold
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (12) : 1679 - 1683
  • [8] Assessment of retinal blood flow using Laser Speckle Flowgraphy
    Schmidl, D.
    Witkowska, K.
    Luft, N.
    Bolz, M.
    Fondi, K.
    Bata, A.
    Wozniak, P.
    Werkmeister, R.
    Garhofer, G.
    Schmetterer, L.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [9] Usefulness of Laser Speckle Flowgraphy for the Assessment of Ocular Blood Flow in Extracranial-Intracranial Bypass
    Omodaka, Shunsuke
    Endo, Hidenori
    Doi, Hiroshi
    Shimizu, Hiroaki
    Fujimura, Miki
    Aizawa, Naoko
    Nakazawa, Toru
    Tominaga, Teiji
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (10): : E445 - E448
  • [10] Ocular blood flow evaluation by laser speckle flowgraphy in pediatric patients with anisometropia
    Itokawa, Takashi
    Matsumoto, Tadashi
    Matsumura, Saiko
    Kawakami, Momoko
    Hori, Yuichi
    FRONTIERS IN PUBLIC HEALTH, 2023, 11