Analysis of MALDI FT-ICR mass spectrometry data: A time series approach

被引:11
|
作者
Barkauskas, Donald A. [1 ]
Kronewitter, Scott R. [2 ]
Lebrilla, Carlito B. [2 ]
Rocke, David M. [3 ]
机构
[1] Childrens Oncol Grp, Arcadia, CA 91006 USA
[2] Univ Calif Davis, Dept Chem, Davis, CA 95616 USA
[3] Univ Calif Davis, Div Biostat, Sch Med, Davis, CA 95616 USA
基金
美国国家卫生研究院;
关键词
Fourier transform ion cyclotron resonance; Generalized gamma distribution; Matrix-assisted laser desorption/ionization; SAMPLES;
D O I
10.1016/j.aca.2009.06.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry is a technique for high mass-resolution analysis of substances that is rapidly gaining popularity as all analytic tool. Extracting signal from the background noise, however, poses significant challenges. In this article, we model the noise part of a spectrum as all autroregressive, moving average (ARMA) time Series with innovations given by a generalized gamma distribution with varying scale parameter but constant shape Parameter and exponent. This enables us to classify peaks found in actual spectra as either noise or signal using a reasonable criterion that outperforms a standard threshold criterion. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [1] Glycoform analysis of intact erythropoietin by MALDI FT-ICR mass spectrometry
    Lippold, Steffen
    Lippold, Steffen
    Thavarajah, Raashina
    Thavarajah, Raashina
    Reusch, Dietmar
    Reusch, Dietmar
    Wuhrer, Manfred
    Wuhrer, Manfred
    Nicolardi, Simone
    Nicolardi, Simone
    ANALYTICA CHIMICA ACTA, 2021, 1185
  • [2] Detecting glycan cancer biomarkers in serum samples using MALDI FT-ICR mass spectrometry data
    Barkauskas, Donald A.
    An, Hyun Joo
    Kronewitter, Scott R.
    de Leoz, Maria Lorna
    Chew, Helen K.
    de Vere White, Ralph W.
    Leiserowitz, Gary S.
    Miyamoto, Suzanne
    Lebrilla, Carlito B.
    Rocke, David M.
    BIOINFORMATICS, 2009, 25 (02) : 251 - 257
  • [3] Compositional analysis of petroleum asphaltenes by FT-ICR mass spectrometry
    Rodgers, Ryan P.
    Klein, Geoffrey C.
    Yen, Andrew T.
    Asomaning, Sam
    Marshall, Alan G.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [4] Metabolomics applications of FT-ICR mass spectrometry
    Brown, SC
    Kruppa, G
    Dasseux, JL
    MASS SPECTROMETRY REVIEWS, 2005, 24 (02) : 223 - 231
  • [5] Effect of apodization on FT-ICR mass spectrometry analysis of petroleum
    Zhang, Linzhou
    Zhang, Yahe
    Zhao, Suoqi
    Chung, Keng H.
    Xu, Chunming
    Shi, Quan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2014, 373 : 27 - 33
  • [6] Activation of large ions in FT-ICR mass spectrometry
    Laskin, J
    Futrell, JH
    MASS SPECTROMETRY REVIEWS, 2005, 24 (02) : 135 - 167
  • [7] Structural Analysis of Monoclonal Antibodies by Ultrahigh Resolution MALDI In-Source Decay FT-ICR Mass Spectrometry
    van der Burgt, Yuri E. M.
    Kilgour, David P. A.
    Tsybin, Yury O.
    Srzentic, Kristina
    Fornelli, Luca
    Beck, Alain
    Wuhrer, Manfred
    Nicolardi, Simone
    ANALYTICAL CHEMISTRY, 2019, 91 (03) : 2079 - 2085
  • [8] Tracking the Magnetron Motion in FT-ICR Mass Spectrometry
    Jertz, Roland
    Friedrich, Jochen
    Kriete, Claudia
    Nikolaev, Evgeny N.
    Baykut, Goekhan
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (08) : 1349 - 1366
  • [9] Automated Electrospray Ionization FT-ICR Mass Spectrometry for Petroleum Analysis
    Kim, Sunghwan
    Rodgers, Ryan P.
    Blakney, Greg T.
    Hendrickson, Christopher L.
    Marshall, Alan G.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (02) : 263 - 268
  • [10] FT-ICR mass spectrometry in the drug discovery process
    Zhang, J
    McCombie, G
    Guenat, C
    Knochenmuss, R
    DRUG DISCOVERY TODAY, 2005, 10 (09) : 635 - 642