Interobserver and Intraobserver Reliability of Cobb Angle Measurement: Endplate Versus Pedicle as Bony Landmarks for Measurement: A Statistical Analysis

被引:16
|
作者
Mehta, Satyen S. [1 ]
Modi, Hitesh N. [1 ]
Srinivasalu, Santhana [1 ]
Chen, Ting [1 ]
Suh, Seung Woo [1 ]
Yang, Jae-Hyuk [1 ]
Song, Hae Ryong [2 ]
机构
[1] Korea Univ, Guro Hosp, Scoliosis Res Inst, Dept Orthopaed, Seoul 152703, South Korea
[2] Korea Univ, Guro Hosp, Rare Dis Inst, Dept Orthopaed, Seoul 152703, South Korea
关键词
Cobb angle; pedicle; endplate; inter/intraobserver variability; ADOLESCENT IDIOPATHIC SCOLIOSIS; CLINICAL MEASUREMENT; BODY HEIGHT; RADIOGRAPHS;
D O I
10.1097/BPO.0b013e3181b72550
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Cobb-Lippman technique measures the curve severity by measuring the angle between the upper and lower endplates of the upper-end and lower-end vertebrae, respectively, using pedicles to measure the angle when they are better visualized than the endplates. Vertebral endplates in younger children provide less distinct bony landmarks and pedicles may be more easily identifiable in these children. The purpose of this study is to evaluate the reliability of the pedicle method of the Cobb angle measurement and compare it with the conventional endplate method of measurement. Methods: Three hundred and eighteen whole spine preoperative anteroposterior radiograms of children with varying degrees of idiopathic scoliosis involving the thoracic spine were evaluated. These radiograms were grouped based on the child's age (< 7 y, 7 to 10 y and > 10 y), the position of the upper-end vertebra (upper-end vertebra at or above T5 and upper-end vertebra caudal to T5), and based on curve severity (mild, < 20 degrees; moderate 20 to 40 degrees, and severe > 40 degrees). Three observers independently examined the radiograms using the endplate method and the pedicle method 3 times each using the digitized computer system. Both intraobserver and interobserver agreements were accessed by calculating the intraclass correlation coefficient (ICCC). In addition, a Bland-Altman plot was made in which the strength of the relationship between the score differences and their mean was indicated by the slope of a regression line. Results: The single ICCC values were better for all observers for < 7-year age group using the pedicle method, indicating lesser intraobserver variability. The average ICCC values, indicating interobserver variability, were similar for all age groups. All the ICCC values lay in the excellent or substantial group. Tests for significance showed no significant difference between the 2 methods of measurement. Conclusions: Differences in measurement values with the pedicle method and end-plate method of measurement of the Cobb angle are not statistically significant. Either method can be used for measurement when using a computer-digitized system, which may have helped to minimize measurement discrepancies between these 2 methods.
引用
收藏
页码:749 / 754
页数:6
相关论文
共 50 条
  • [1] Reliability analysis of Cobb measurement in degenerative lumbar scoliosis using endplate versus pedicle as bony landmarks
    Guo, Jing
    Deng, Xian-chao
    Ling, Qin-jie
    Yin, Zhi-xun
    He, Er-xing
    POSTGRADUATE MEDICINE, 2017, 129 (07) : 762 - 767
  • [3] Inter- and intraobserver reliability assessment of the Cobb angle: manual versus digital measurement tools
    Gstoettner, Michaela
    Sekyra, Katrin
    Walochnik, Nadja
    Winter, Peter
    Wachter, Roland
    Bach, Christian M.
    EUROPEAN SPINE JOURNAL, 2007, 16 (10) : 1587 - 1592
  • [4] Inter- and intraobserver reliability assessment of the Cobb angle: manual versus digital measurement tools
    Michaela Gstoettner
    Katrin Sekyra
    Nadja Walochnik
    Peter Winter
    Roland Wachter
    Christian M. Bach
    European Spine Journal, 2007, 16 : 1587 - 1592
  • [5] Cobb Angle Measurement of Scoliosis Using Computer Measurement of Digitally Acquired Radiographs-Intraobserver and Interobserver Variability
    Srinivasalu, S.
    Modi, Hitesh N.
    SMehta, Satyen
    Suh, Seung-Woo
    Chen, Ting
    Murun, Temuujin
    ASIAN SPINE JOURNAL, 2008, 2 (02) : 90 - 93
  • [6] MEASUREMENT OF ULTRASOUND BIOMICROSCOPY IMAGES - INTRAOBSERVER AND INTEROBSERVER RELIABILITY
    TELLO, C
    LIEBMANN, J
    POTASH, SD
    COHEN, H
    RITCH, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (09) : 3549 - 3552
  • [7] Spondylolisthesis: Intraobserver and Interobserver Reliability With Regard to the Measurement of Slip Percentage
    McCarty, Mary E.
    Mehlman, Charles T.
    Tamai, Junichi
    Do, Twee T.
    Crawford, Alvin H.
    Klein, Guy
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2009, 29 (07) : 755 - 759
  • [8] Measurement of rib vertebral angle difference - Intraobserver error and interobserver variation
    McAlindon, RJ
    Kruse, RW
    SPINE, 1997, 22 (02) : 198 - 199
  • [9] Intraobserver and Interobserver Measurement Variability of the Rib-Vertebral Angle Difference
    Tysklind, Robert G.
    Myung, Karen
    Gantsoudes, George
    Kishan, Shyam
    Turner, Chad
    Lee, Stella
    Wanner, Matthew
    Sabatino, Meagan
    Linger, Scott
    Loder, Randall T.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2018, 38 (09) : 455 - 458
  • [10] Interobserver and intraobserver reliability of the measurement of shoulder internal rotation by vertebral level
    Edwards, TB
    Bostick, RD
    Greene, CC
    Baratta, RV
    Drez, D
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (01) : 40 - 42