Linear Approximations for the Influence of Phasor Angle Difference Errors on Line Parameter Calculation

被引:25
|
作者
Xue, Ancheng [1 ]
Xu, Feiyang [1 ]
Martin, Kenneth E. [2 ]
Xu, Jingsong [1 ,3 ]
You, Hongyu [1 ,4 ]
Bi, Tianshu [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] Elect Power Grp, Pasadena, CA 91101 USA
[3] State Grid Ningxia Yinchuan Elect Power Co, Yinchuan 750001, Peoples R China
[4] State Grid Shanghai Municipal Elect Power Co, Shanghai 200122, Peoples R China
基金
中国国家自然科学基金;
关键词
Phase angle difference error; synchronization error; PMU; line parameter calculation; UNCERTAINTY; IMPACT;
D O I
10.1109/TPWRS.2019.2902885
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Phase angle measurements from phasor measurement units (PMUs) may have errors that can significantly affect line parameter calculation. In this paper, approximate expressions for the influence of phase angle difference errors on line parameter calculation are derived. Specifically, first the PMU phase angle error at both ends of a line is analyzed and an equivalent synchronization error is defined; second, approximated expressions for the influence of current and voltage phase angle difference error on the line parameters are derived. The voltage amplitude ratio on the relative error of line reactance, resistance, and capacitance measurement through the pi-type equivalent model are considered. The influence of voltage and current phase angle difference error on reactance and resistance is shown from the perspective of relative sensitivity. The relative sensitivity expressions in active power form are given and the identifiable conditions of line reactance parameters based on PMU data are given. In addition, this paper presents the influence mechanism of voltage magnitude and discusses the case of synchronization issue. Finally, the accuracy of the sensitivity equations is verified by simulations, and the influence of the voltage amplitude ratio and the line flow on the identification result is quantitatively analyzed.
引用
收藏
页码:3455 / 3464
页数:10
相关论文
共 6 条
  • [1] Linear Approximations for the Influence of Phasor Angle Difference Errors on Line Parameter Calculation
    Xue, Ancheng
    Xu, Feiyang
    Martin, Kenneth E.
    Xu, Jingsong
    You, Hongyu
    Bi, Tianshu
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [3] THE INFLUENCE OF ERRORS OF ARRHENIUS PARAMETER CALCULATION ON THE EXACTNESS OF THE SOLUTION OF THE DIRECT KINETIC PROBLEM
    VYAZOVKIN, SV
    LESNIKOVICH, AI
    THERMOCHIMICA ACTA, 1991, 182 (01) : 133 - 142
  • [4] Substation bus voltage angle calculation method using voltage angle difference measured at the tie switch in the distribution line
    Son J.-H.
    Lim S.-I.
    Lim, Seong-Il (slim@kyungnam.ac.kr), 1600, Korean Institute of Electrical Engineers (65): : 9 - 15
  • [5] Influence of tangential hydrodynamic force and inclination angle calculation on the dynamic responses analysis of mooring line based on lumped mass method
    Wang, Ziming
    Qiao, Dongsheng
    Wu, Qingshuai
    Tang, Guoqiang
    Lu, Lin
    Ou, Jinping
    OCEAN & COASTAL MANAGEMENT, 2024, 255
  • [6] Estimation of stability of oscillations of linear time-varying systems with one time-varying parameter with calculation of influence of higher frequency motions
    Mandrik A.V.
    Automatic Control and Computer Sciences, 2017, 51 (3) : 141 - 148