Portable system for CWA detection using micro array gas sensor

被引:0
|
作者
Kwak, J. H.
Lim, Y. T.
Kim, G. H.
Choi, N. J.
Park, H. D.
Rue, G. H.
Huh, J. S.
Kim, J. C.
Lee, D. D. [1 ]
机构
[1] Kyungpook Natl Univ, Sch Elect Engn & Comp Sci, Taegu 1370, South Korea
[2] Elect & Telecommun Res Inst, Future Technol Res Div, New Funct Informat Devices Team, Taejon 161, South Korea
关键词
SnO2; chemical warfare agents (CWAs); portable system; ART; array; PCA;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Biochemistry weapon is raising new tools of war and terror. This research is an experiment about portable system for CWAs (chemical warfare agents) detection using micro array gas system. CWAs were divided into four types such as blood, nerve, vesicant, and choking agent. To detect various CWAs, semiconductor thick film sensor array based on tin oxide was fabricated and their gas responses were examined. Operating temperature was range of 250 degrees C to 350 degrees C and gas concentration was range of 0.1 mu g/g to 10 mu g/g. Sensor array was measured as operating temperatures, concentrations for four simulant agents of CWAs. Extracted parameters from results were carried out classification among CWAs through the principal component analysis (PCA). Also, classification of gases is studied using adaptive resonance theory (ART) that is one of neural network algorithm. Results displayed using PDA system.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [1] Portable System for CWA Detection Using Micro Array Gas Sensor
    JHKwak
    YTLim
    GHKim
    NJChoi
    HDPark
    GHRue
    JSHuh
    JCKim
    DDLee
    稀有金属材料与工程, 2006, (S3) : 124 - 128
  • [2] Portable Sensor Array System for Intelligent Recognizer of Manhole Gas
    Ghosh, Sugato
    Saha, Hiranmay
    RoyChaudhuri, Chirasree
    Ojha, Varun Kr
    Dutta, Paramartha
    2012 SIXTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2012, : 589 - 594
  • [3] Evaluation of the efficacy of a portable LIBS system for detection of CWA on surfaces
    L'Hermite, D.
    Vors, E.
    Vercouter, T.
    Moutiers, G.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (09) : 8219 - 8226
  • [4] Electronic nose system with micro gas sensor array
    Hong, HK
    Shin, HW
    Yun, DH
    Kim, SR
    Kwon, CH
    Lee, K
    Moriizumi, T
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 36 (1-3) : 338 - 341
  • [5] Evaluation of the efficacy of a portable LIBS system for detection of CWA on surfaces
    D. L’Hermite
    E. Vors
    T. Vercouter
    G. Moutiers
    Environmental Science and Pollution Research, 2016, 23 : 8219 - 8226
  • [6] Portable electronic nose system with gas sensor array and artificial neural network
    Hong, HK
    Kwon, CH
    Kim, SR
    Yun, DH
    Lee, K
    Sung, YK
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) : 49 - 52
  • [7] FIRE DETECTION USING A GAS SENSOR ARRAY WITH SENSOR FUSION ALGORITHMS
    Solorzano, A.
    Fonollosa, J.
    Fernandez, L.
    Eichmann, J.
    Marco, S.
    2017 ICOCS/IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2017), 2017,
  • [8] Detection of mastitic milk using a gas-sensor array system (electronic nose)
    Eriksson, Å
    Waller, KP
    Svennersten-Sjaunja, K
    Haugen, JE
    Lundby, F
    Lind, O
    INTERNATIONAL DAIRY JOURNAL, 2005, 15 (12) : 1193 - 1201
  • [9] Classifying combustible gases using micro-gas sensor array
    Lee, DS
    Huh, JS
    Lee, DD
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3): : 1 - 6
  • [10] Portable electronic nose system with gas sensor array and artificial neural-network
    Hong, HK
    Kwon, CH
    Kim, SR
    Yun, DH
    Lee, K
    Sung, YK
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 704 - 706