Local deformation calibration for autostereoscopic 3D display

被引:10
|
作者
Hwang, Hyoseok [1 ,2 ]
Chang, Hyun Sung [2 ]
Kweon, In So [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, 291 Daehak Ro, Daejon 34141, South Korea
[2] SAIT, Samsung Elect, 130 Samsung Ro, Suwon 16678, South Korea
来源
OPTICS EXPRESS | 2017年 / 25卷 / 10期
关键词
INTEGRAL IMAGING DISPLAY; QUALITY; FIELD; MULTIVIEW; PARALLAX; PANEL;
D O I
10.1364/OE.25.010801
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Calibration is vital to autostereoscopic 3D displays. This paper proposes a local calibration method that copes with any type of deformation in the optical layer. The proposed method is based on visual pattern analysis. Given the observations, we manage to localize the optical slits by matching the observations to the input pattern. In a principled optimization framework, we find an efficient calibration algorithm. Experimental validation follows. The local calibration shows significant improvement in 3D visual quality over the global calibration method. This paper also finds a new intuitive insight on the calibration in terms of the light field theory. (C) 2017 Optical Society of America.
引用
收藏
页码:10801 / 10814
页数:14
相关论文
共 50 条
  • [1] 3D Mouse Realization in Autostereoscopic Display
    Jia, Zhentang
    Han, Yanfang
    MULTIMEDIA AND SIGNAL PROCESSING, 2012, 346 : 367 - 374
  • [2] Accurate 3D autostereoscopic display using optimized parameters through quantitative calibration
    Fan, Zhencheng
    Chen, Guowen
    Xia, Yan
    Huang, Tianqi
    Liao, Hongen
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2017, 34 (05) : 804 - 812
  • [3] Autostereoscopic 3D Display System for 3D Medical Images
    Kang, Dongwoo
    Choi, Jin-Ho
    Hwang, Hyoseok
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [4] Observer tracking autostereoscopic 3D display systems
    Woodgate, Graham J.
    Ezra, David
    Harrold, Jonathan
    Holliman, Nicolas S.
    Jones, Graham R.
    Moseley, Richard R.
    Shapu Giho/Sharp Technical Journal, 1997, (69): : 57 - 63
  • [5] 3D Quantitative Evaluation System for Autostereoscopic Display
    Fan, Zhencheng
    Zhang, Sen
    Weng, Yitong
    Chen, Guowen
    Liao, Hongen
    JOURNAL OF DISPLAY TECHNOLOGY, 2016, 12 (10): : 1185 - 1196
  • [6] The potential use of an autostereoscopic 3D display in microsurgery
    Chios, P
    Tan, AC
    Linney, AD
    Alusi, GH
    Wright, A
    Woodgate, GJ
    Ezra, D
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 998 - 1009
  • [7] Holoscopic 3D Image Rendering for Autostereoscopic Multiview 3D Display
    Swash, M. R.
    Aggoun, A.
    Abdulfatah, O.
    Li, B.
    Fernandez, J. C.
    Tsekleves, E.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON BROADBAND MULTIMEDIA SYSTEMS AND BROADCASTING (BMSB), 2013,
  • [8] Autostereoscopic 3D display systems with observer tracking
    Woodgate, GJ
    Ezra, D
    Harrold, J
    Holliman, NS
    Jones, GR
    Moseley, RR
    SIGNAL PROCESSING-IMAGE COMMUNICATION, 1998, 14 (1-2) : 131 - 145
  • [9] Evaluation of a 3D autostereoscopic display for telerobotic operations
    Lee, BC
    Katafiaz, ME
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS IV, 1997, 3012 : 48 - 58
  • [10] Flat-panel autostereoscopic 3D display
    Lee, C. M. G.
    Travis, A. R. L.
    Lin, R.
    IET OPTOELECTRONICS, 2008, 2 (01) : 24 - 28