Influence of isometric voluntary contraction on time and frequency domain parameters of surface EMG

被引:2
|
作者
Kaplanis, PA [1 ]
Pattichis, CS [1 ]
Roberts, CV [1 ]
机构
[1] Cyprus Inst Neurol & Genet, Nicosia, Cyprus
关键词
surface EMG; isometric voluntary contraction;
D O I
10.1109/IEMBS.2002.1053348
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The main objective of this paper was to investigate the effect of increase of isometric voluntary contraction (IVC) on surface EMG recorded from the Biceps Brachii (BB) muscle. Five different force levels (FL) were used: 10, 30, 50, 70 and 100% of maximum voluntary contraction (MVC), with each recording lasting 5 seconds. The following sets of parameters were extracted: (i) in the time domain (turns (ts) and zero crossings per second (zc)), and (H) in the frequency domain (median frequency (fp), frequency at maximum power (fx), maximum power (Px), and total power (Pt)). A total of 91 normal subjects aged between 5 and 69 years old were analyzed. The Wilcoxon paired two-tailed test (p<0.05), was used to classify changes in parameters examined as significant (S) or non-significant (NS) during transition from a force level to another. Results showed that: ts, zc, Px, and Pt increase with force whereas fp decreases with force. Moreover, these parameters showed significant difference between the different force levels examined.
引用
收藏
页码:2408 / 2409
页数:2
相关论文
共 50 条
  • [1] THEORETICAL-ANALYSIS OF SURFACE EMG IN VOLUNTARY ISOMETRIC CONTRACTION
    MIYANO, H
    SADOYAMA, T
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1979, 40 (03): : 155 - 164
  • [2] Surface EMG analysis on normal subjects based on isometric voluntary contraction
    Kaplanis, P. A.
    Pattichis, C. S.
    Hadjileontiadis, L. J.
    Roberts, V. C.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (01) : 157 - 171
  • [3] MOTOR UNIT DIFFERENTIATION AND INTEGRATED SURFACE EMG IN VOLUNTARY ISOMETRIC CONTRACTION
    MATON, B
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1976, 35 (02): : 149 - 157
  • [4] Effect of Inter-electrode Distance on Frequency Parameters of Surface EMG During Isometric Contraction
    Hajian, Gelareh
    Morin, Evelyn
    De, Ashmita
    2016 IEEE EMBS INTERNATIONAL STUDENT CONFERENCE (ISC), 2016,
  • [5] Quantitative analysis of EMG amplitude estimator for surface emg signal recorded during isometric constant voluntary contraction
    Lee J.
    Lee, Jin (jlee@kangwon.ac.kr), 1600, Korean Institute of Electrical Engineers (66): : 843 - 850
  • [6] Repeatability of maximal voluntary force and of surface EMG variables during voluntary isometric contraction of quadriceps muscles in healthy subjects
    Rainoldi, A
    Bullock-Saxton, JE
    Cavarretta, F
    Hogan, N
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2001, 11 (06) : 425 - 438
  • [7] Standard Maximum Isometric Voluntary Contraction Tests for Normalizing Shoulder Muscle EMG
    Boettcher, Craig E.
    Ginn, Karen A.
    Cathers, Ian
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (12) : 1591 - 1597
  • [8] A comparison of two gluteus maximus EMG maximum voluntary isometric contraction positions
    Contreras, Bret
    Vigotsky, Andrew D.
    Schoenfeld, Brad J.
    Beardsley, Chris
    Cronin, John
    PEERJ, 2015, 3
  • [9] A STUDY ON THE CHANGES OF EMG ACTIVITY DURING VOLUNTARY ISOMETRIC CONTRACTION IN MASTICATORY MUSCLES
    CHANG, H
    CHOI, BB
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 599 - 599
  • [10] RELATIONSHIP BETWEEN FORCE AND INTEGRATED EMG ACTIVITY DURING VOLUNTARY ISOMETRIC ANISOTONIC CONTRACTION
    METRAL, S
    CASSAR, G
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1981, 46 (02) : 185 - 198