Fenestration refurbishment of an educational building: Experimental and numerical evaluation of daylight, thermal and building energy performance

被引:12
|
作者
Boafo, Fred Edmond [1 ]
Ahn, Jong-Gwon [1 ]
Kim, Sang-Myung [1 ]
Kim, Jin-Hee [2 ]
Kim, Jun-Tae [3 ,4 ]
机构
[1] Kongju Natl Univ, Zero Energy Bldg Lab, Grad Sch Energy Syst Engn, Cheonan 31080, Chungnam, South Korea
[2] Kongju Natl Univ, Green Energy Technol Res Ctr, Cheonan 31080, Chungnam, South Korea
[3] Kongju Natl Univ, Dept Architectural Engn, Cheonan 31080, Chungnam, South Korea
[4] Kongju Natl Univ, Grad Sch Energy Syst Engn, Cheonan 31080, Chungnam, South Korea
关键词
Fenestration refurbishment; Double-sliding window system; Thermal behavior; Daylight; Building energy; INFRARED THERMOGRAPHY; CONSUMPTION; TECHNOLOGIES; ENVELOPE;
D O I
10.1016/j.jobe.2019.100803
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although strict building energy codes are implemented periodically in many countries, buildings continually consume a momentous quota of total primary energy. Potentially, new buildings can satisfy current building energy codes, while existing buildings require refurbishment. Recently, the fenestration system of a 4-story educational building located in Cheonan, Republic of Korea (36.815 degrees N, 127.114 degrees E) has been refurbished from single glazed double-sliding window system with aluminum (Al) frame to double low-e glazed double-sliding window system with polyvinyl chloride (PVC) frame. The main objective of this study was to investigate the performance of the window system prior to and after refurbishment, using experimental and numerical tools. In particular, daylight environment of a demarcated space within the reference building was examined. Thermal behavior of glazing systems and window frames was scrutinized using infra-red (IR) thermography. The dynamic behavior of window system in relation to building energy performance was evaluated through EnergyPlus. Reference data of the building and nominal operational schedules were used as inputs for the building model, while inputs for the window system were based on optical and structural parameters of its data sets. Owing to thermal inertia, temperature of the single glazing was on average 0.7-1.9 degrees C higher than the double glazing. Considering linear radiant heat loss through Al and PVC frames, the former showed an avearge temperature of 5 degrees C higher than the latter. Although electrical lighting energy consumption increased, the overall annual building energy consumption of the renovated building reduced by 51.1 GJ (i.e. 4.3%).
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Performance evaluation of building integrated solar thermal shading system: Building energy consumption and daylight provision
    Li, Li
    Qu, Ming
    Peng, Steve
    ENERGY AND BUILDINGS, 2016, 113 : 189 - 201
  • [2] The Performance of Daylight through Various Type of Fenestration in Residential Building
    Husin, Sharifah Nor Fairuz Syed
    Harith, Zarina Yasmin Hanur
    ASEAN CONFERENCE ON ENVIRONMENT-BEHAVIOUR STUDIES (ACE-BS), 2012, 36 : 196 - 203
  • [3] Thermal and Daylight Evaluation of Building Zones
    Altan, Hasim
    Mohelnikova, Jitka
    Hofman, Petr
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2784 - 2789
  • [4] Numerical and experimental study on the performance of a thermal energy storage in a solar building
    Peng, Li
    Wu, Hongjun
    Mao, Qianjun
    JOURNAL OF ENERGY STORAGE, 2023, 61
  • [5] EFFECT OF BUILDING FORM ON DAYLIGHT AND ENERGY EFFICIENCY FOR EDUCATIONAL BUILDING IN COMPOSITE CLIMATE
    Chaturvedi, Pushpendra
    Kumar, Nand
    Lamba, Ravita
    Nachan, Pushkar
    Proceedings - ISES Solar World Congress 2023, SWC 2023, 2024, : 436 - 445
  • [6] Experimental characterization of the thermal performance of a school building prototype before and after refurbishment
    Barbosa, Francisca Cavaleiro
    de Freitas, Vasco Peixoto
    Almeida, Manuela
    4TH CENTRAL EUROPEAN SYMPOSIUM ON BUILDING PHYSICS (CESBP 2019), 2019, 282
  • [7] Performance Evaluation of an Energy Efficient Educational Building in India
    Maaz, Dixit
    Sanyogita, Manu
    Rajat, Gupta
    Arihant, Jain
    SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 3, 2018, : 1041 - 1042
  • [8] Numerical and experimental analysis of building walls thermal performance
    Al Fakhoury, Joelle
    Sassine, Emilio
    Cherif, Yassine
    Dgheim, Joseph
    Antczak, Emmanuel
    JOURNAL OF BUILDING PHYSICS, 2024, 48 (01) : 5 - 30
  • [9] Experimental and numerical comparison of internal insulation systems for building refurbishment
    Manzan, Marco
    De Zorzi, Ezio Zandegiacomo
    Lorenzi, Walter
    70TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, ATI2015, 2015, 82 : 493 - 498
  • [10] Experimental and numerical study of an energy-efficient building fenestration system with seasonal adaptability
    Wang, Chuyao
    Yang, Hongxing
    Ji, Jie
    BUILDING AND ENVIRONMENT, 2023, 244