Measuring the efficacy of positioning aids for capturing 3D data in different clothing configurations and postures with a high-resolution whole-body scanner

被引:11
|
作者
Schwarz-Mueller, Frank [1 ,2 ]
Marshall, Russell [1 ]
Summerskill, Steve [1 ]
Poredda, Christoph [3 ]
机构
[1] Loughborough Univ, Sch Design & Creat Arts, Loughborough LE11 3TU, Leics, England
[2] Fed Off Bundeswehr Equipment Informat Technol & I, Ferdinand Sauerbruch Str 1, D-56073 Koblenz, Germany
[3] Bundeswehr Tech Ctr Land Based Vehicle Syst Engn, D-54296 Trier, Germany
关键词
Body scanning; Positioning aid; Clothed anthropometry; Human variability; ERRORS;
D O I
10.1016/j.measurement.2020.108519
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Numerous surveys have been conducted worldwide to capture 3D anthropometric data of individuals scanned in tight underwear. However, such semi-nude data are inadequate for designing workspaces for specialised user populations who wear protective clothing and equipment. Determining the offset between semi-nude and clothed configurations requires the same individual to be repeatedly scanned in exactly the same posture. Specifically, for the use in a high-resolution 3D body scanner, positioning aids for the standing and seated posture were developed to stabilise the posture during the scanning process without compromising data integrity. The mean absolute variability (MAV) index was introduced to determine the efficacy of the positioning aids. It was shown that the positioning aids efficiently reduce the variability in fore-and-aft and side-to-side directions. This way the precondition was created for the precise superimposition of scans permitting the offset between diverse clothing configurations to be determined.
引用
收藏
页数:14
相关论文
共 7 条
  • [1] Whole-body 3D scanner and scan data report
    Addleman, S
    THREE-DIMENSIONAL IMAGE CAPTURE, 1997, 3023 : 2 - 5
  • [2] A high-resolution and whole-body dataset of hand-object contact areas based on 3D scanning method
    Chen, Zelin
    Chen, Hanlu
    Ouyang, Yiming
    Cao, Chenhao
    Gao, Wei
    Hu, Qiqiang
    Jin, Hu
    Zhang, Shiwu
    SCIENTIFIC DATA, 2025, 12 (01)
  • [3] Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole-body 3D magnetic resonance angiography
    Goyen, M
    Herborn, CU
    Lauenstein, TC
    Barkhausen, J
    Veit, P
    Bosk, S
    Debatin, JF
    Ruehm, SG
    INVESTIGATIVE RADIOLOGY, 2002, 37 (05) : 263 - 268
  • [4] High-Resolution MRS in the Presence of Field Inhomogeneity via Intermolecular Double-Quantum Coherences on a 3-T Whole-Body Scanner
    Lin, Yanqin
    Gu, Tianliang
    Chen, Zhong
    Kennedy, Scott
    Jacob, Mathews
    Zhong, Jianhui
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 303 - 311
  • [5] A Novel Receive-Only Liquid Nitrogen (LN2)-Cooled RF Coil for High-Resolution In Vivo Imaging on a 3-Tesla Whole-Body Scanner
    Hu, Bobo
    Varma, Gopal
    Randell, Chris
    Keevil, Stephen F.
    Schaeffter, Tobias
    Glover, Paul
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (01) : 129 - 139
  • [6] High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation
    Christoph Forman
    Davide Piccini
    Robert Grimm
    Jana Hutter
    Joachim Hornegger
    Michael O. Zenge
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 435 - 443
  • [7] High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation
    Forman, Christoph
    Piccini, Davide
    Grimm, Robert
    Hutter, Jana
    Hornegger, Joachim
    Zenge, Michael O.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (05) : 435 - 443