ENDOR with band-selective shaped inversion pulses

被引:12
|
作者
Tait, Claudia E. [1 ]
Stoll, Stefan [1 ]
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
ENDOR; EPR; Hyperfine interaction; AWG; Arbitrarily shaped pulses; Band-selective inversion pulses; Finite Fourier series pulses; Gaussian pulse cascades; RESONANCE SPECTROSCOPY; ACCOMMODATE RELAXATION; EXCITATION PULSES; EPR; NMR;
D O I
10.1016/j.jmr.2017.02.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electron Nuclear DOuble Resonance (ENDOR) is based on the measurement of nuclear transition frequencies through detection of changes in the polarization of electron transitions. In Davies ENDOR, the initial polarization is generated by a selective microwave inversion pulse. The rectangular inversion pulses typically used are characterized by a relatively low selectivity, with full inversion achieved only for a limited number of spin packets with small resonance offsets. With the introduction of pulse shaping to EPR, the rectangular inversion pulses can be replaced with shaped pulses with increased selectivity. Band selective inversion pulses are characterized by almost rectangular inversion profiles, leading to full inversion for spin packets with resonance offsets within the pulse excitation bandwidth and leaving spin packets outside the excitation bandwidth largely unaffected. Here, we explore the consequences of using different band-selective amplitude-modulated pulses designed for NMR as the inversion pulse in ENDOR. We find an increased sensitivity for small hyperfine couplings compared to rectangular pulses of the same bandwidth. In echo-detected Davies-type ENDOR, finite Fourier series inversion pulses combine the advantages of increased absolute ENDOR sensitivity of short rectangular inversion pulses and increased sensitivity for small hyperfine couplings of long rectangular inversion pulses. The use of pulses with an almost rectangular frequency-domain profile also allows for increased control of the hyperfine contrast selectivity. At X-band, acquisition of echo transients as a function of radiofrequency and appropriate selection of integration windows during data processing allows efficient separation of contributions from weakly and strongly coupled nuclei in overlapping ENDOR spectra within a single experiment. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:36 / 44
页数:9
相关论文
共 50 条
  • [1] BAND-SELECTIVE RADIOFREQUENCY PULSES
    GEEN, H
    FREEMAN, R
    JOURNAL OF MAGNETIC RESONANCE, 1991, 93 (01): : 93 - 141
  • [2] BAND-SELECTIVE PULSES DESIGNED TO ACCOMMODATE RELAXATION
    NUZILLARD, JM
    FREEMAN, R
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 107 (01) : 113 - 118
  • [3] Band-selective hetero- and homonuclear cross-polarization using trains of shaped pulses
    Zuiderweg, ERP
    Zeng, L
    Brutscher, B
    Morshauser, RC
    JOURNAL OF BIOMOLECULAR NMR, 1996, 8 (02) : 147 - 160
  • [4] OPTIMIZATION OF MULTIDIMENSIONAL NMR USING BAND-SELECTIVE PULSES
    BRUTSCHER, B
    SIMORRE, JP
    MARION, D
    JOURNAL OF MAGNETIC RESONANCE, 1992, 100 (02): : 416 - 424
  • [5] A COMPARISON OF TAILORED BAND-SELECTIVE PULSES IN TRIPLE-RESONANCE EXPERIMENTS
    PLANT, D
    INGLIS, B
    MARECI, T
    JOURNAL OF CELLULAR BIOCHEMISTRY, 1995, : 75 - 75
  • [6] BAND-SELECTIVE DECOUPLING
    KUPCE, E
    FREEMAN, R
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 102 (03) : 364 - 369
  • [7] Band-selective shaped pulse for high fidelity quantum control in diamond
    Chang, Yan-Chun
    Xing, Jian
    Zhang, Fei-Hao
    Liu, Gang-Qin
    Jiang, Qian-Qing
    Li, Wu-Xia
    Gu, Chang-Zhi
    Long, Gui-Lu
    Pan, Xin-Yu
    APPLIED PHYSICS LETTERS, 2014, 104 (26)
  • [8] BAND-SELECTIVE PULSES WITHOUT PHASE-DISTORTION - A SIMULATED ANNEALING APPROACH
    GEEN, H
    WIMPERIS, S
    FREEMAN, R
    JOURNAL OF MAGNETIC RESONANCE, 1989, 85 (03): : 620 - 627
  • [9] ASYMMETRIC AMPLITUDE-MODULATED RADIOFREQUENCY PULSES AND THEIR APPLICATION TO BAND-SELECTIVE DECOUPLING
    STARCUK, Z
    BARTUSEK, K
    STARCUK, Z
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 104 (03) : 340 - 344
  • [10] BAND-SELECTIVE HETERONUCLEAR DECOUPLING USING SHAPED PULSES AS AN AID IN MEASURING LONG-RANGE HETERONUCLEAR COUPLING-CONSTANTS
    ZUIDERWEG, ERP
    FESIK, SW
    JOURNAL OF MAGNETIC RESONANCE, 1991, 93 (03): : 653 - 658