Experimental study on natural ventilation of a room with a windward window and different windexchangers

被引:25
|
作者
Cruz-Salas, M. V. [1 ]
Castillo, J. A. [1 ]
Huelsz, G. [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Energias Renovables, Temixco 62580, Morelos, Mexico
关键词
Natural ventilation; Windexchanger; Windcatcher; Experiments; Water channel; SPIV; CROSS-VENTILATION; FLUID-MECHANICS; PERFORMANCE; DRIVEN; CFD; DISPLACEMENT; BUILDINGS; SCALE;
D O I
10.1016/j.enbuild.2014.08.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A windexchanger is a small structure placed on the roof of a building with the aim of increasing the wind driven ventilation. In the literature, this structure is usually named as a windcatcher. Depending on its orientation to the wind direction, the same structure can perform as a windcatcher or a windextractor. Six windexchanger configurations with different wind orientations, placed in a room with a window at windward, are experimentally evaluated. The room without a windexchanger is used as a reference. The experiments were carried out in a water channel using scale models. Flow velocity measurements were performed using stereoscopic particle image velocimetry (SPIV) on the central plane. The velocity vertical profile in the test section corresponding to a small town was generated. The flow rate into the building and the area percentage of the central plane with flow speed greater than a reference value are used as evaluation parameters. It was found that, the performance of a windexchanger strongly depends on the orientation of its openings to the wind. The ventilation performance of the room with a windexchanger ranges from a significant to a negligible improvement. This stresses the importance of the adequate design of this kind of structure. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:458 / 465
页数:8
相关论文
共 50 条
  • [1] Natural ventilation of an isolated generic building with a windward window and different windexchangers: CFD validation, sensitivity study and performance analysis
    J. Antonio Castillo
    Guadalupe Huelsz
    Twan van Hooff
    Bert Blocken
    Building Simulation, 2019, 12 : 475 - 488
  • [2] Natural ventilation of an isolated generic building with a windward window and different windexchangers: CFD validation, sensitivity study and performance analysis
    Antonio Castillo, J.
    Huelsz, Guadalupe
    van Hooff, Twan
    Blocken, Bert
    BUILDING SIMULATION, 2019, 12 (03) : 475 - 488
  • [3] Natural ventilation by windexchangers in a building with a window in prevailing winds: design guidelines
    Castillo, J. A.
    Cruz-Salas, M. V.
    Huelsz, G.
    INTERNATIONAL JOURNAL OF VENTILATION, 2017, 16 (01) : 1 - 14
  • [4] Research of window's discharge coefficient in the natural ventilation room
    Liao, Qihai
    Guan, Yanling
    Wang, Qiaoning
    DEVELOPMENT OF INDUSTRIAL MANUFACTURING, 2014, 525 : 420 - 426
  • [5] Experimental validation of basic natural ventilation air flow calculations for different flow path and window configurations
    Erhart, T.
    Guerlich, D.
    Schulze, T.
    Eicker, U.
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2838 - 2843
  • [6] Experimental and CFD study of ventilation performance enhanced by roof window and mechanical ventilation system with different design strategies
    He, Yi
    Chu, Yingnan
    Zang, Haiyan
    Zhao, Jinyan
    Song, Yehao
    BUILDING AND ENVIRONMENT, 2022, 224
  • [7] An experimental study on ventilation efficiency of isolation room
    Tung, Yun-Chun
    Hu, Shih-Cheng
    Tsai, Tung-I
    Chang, I-Lang
    BUILDING AND ENVIRONMENT, 2009, 44 (02) : 271 - 279
  • [8] Experimental Study of Air Distribution and Ventilation Effectiveness in a Room with a Combination of Different Mechanical Ventilation and Heating/Cooling Systems
    Olesen, Bjarne W.
    Simone, Angela
    Krajcik, Michal
    Causone, Francesco
    De Carli, Michele
    INTERNATIONAL JOURNAL OF VENTILATION, 2011, 9 (04) : 371 - 383
  • [9] Natural ventilation in a room with a horizontal cylindrical heat source, a window and bottom or top vents
    Antonio Castillo, J.
    Tovar, Ramon
    Huelsz, Guadalupe
    BUILDING AND ENVIRONMENT, 2021, 191
  • [10] Study of buoyant jets in natural ventilation of a model room
    Subudhi, Sudhakar
    Sreenivas, K. R.
    Arakeri, Jaywant H.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 : 91 - 97