Reducing muscle fatigue during transcutaneous neuromuscular electrical stimulation by spatially and sequentially distributing electrical stimulation sources

被引:64
|
作者
Sayenko, Dimitry G. [1 ]
Nguyen, Robert [2 ]
Popovic, Milos R. [3 ,4 ]
Masani, Kei [3 ,4 ]
机构
[1] Univ Louisville, Frazier Rehab Inst, Dept Neurol Surg, Louisville, KY 40202 USA
[2] ETH, Automat Control Lab, CH-8092 Zurich, Switzerland
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 3G9, Canada
[4] Univ Hlth Network, Toronto Rehabil Inst, Rehabil Engn Lab, Lyndhurst Ctr, Toronto, ON M4G 3V9, Canada
基金
加拿大健康研究院;
关键词
Electromyography; Muscle contractile properties; Muscle fatigue; Neuromuscular electrical stimulation; SPINAL-CORD-INJURY; MAXIMAL VOLUNTARY CONTRACTIONS; PARALYZED SOLEUS MUSCLE; SKELETAL-MUSCLE; RANDOM MODULATION; MOUSE MUSCLE; RELAXATION; ADAPTATIONS; CAT; INDIVIDUALS;
D O I
10.1007/s00421-013-2807-4
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A critical limitation with transcutaneous neuromuscular electrical stimulation is the rapid onset of muscle fatigue. We have previously demonstrated that spatially distributed sequential stimulation (SDSS) shows a drastically greater fatigue-reducing ability compared to a single active electrode stimulation (SES). The purposes of this study were to investigate (1) the fatigue-reducing ability of SDSS in more detail focusing on the muscle contractile properties and (2) the mechanism of this effect using array-arranged electromyogram (EMG). SDSS was delivered through four active electrodes applied to the plantarflexors, sending a stimulation pulse to each electrode one after another with 90A degrees phase shift between successive electrodes. In the first experiment, the amount of exerted ankle torque and the muscle contractile properties were investigated during a 3 min fatiguing stimulation. In the second experiment, muscle twitch potentials with SDSS and SES stimulation electrode setups were compared using the array-arranged EMG. The results demonstrated negligible torque decay during SDSS in contrast to considerable torque decay during SES. Moreover, small changes in the muscle contractile properties during the fatiguing stimulation using SDSS were observed, while slowing of muscle contraction and relaxation was observed during SES. Further, the amplitude of the M-waves at each muscle portion was dependent on the location of the stimulation electrodes during SDSS. We conclude that SDSS is more effective in reducing muscle fatigue compared to SES, and the reason is that different sets of muscle fibers are activated alternatively by different electrodes.
引用
收藏
页码:793 / 804
页数:12
相关论文
共 50 条
  • [1] Reducing muscle fatigue during transcutaneous neuromuscular electrical stimulation by spatially and sequentially distributing electrical stimulation sources
    Dimitry G. Sayenko
    Robert Nguyen
    Milos R. Popovic
    Kei Masani
    European Journal of Applied Physiology, 2014, 114 : 793 - 804
  • [2] Spatially Distributed Sequential Stimulation Reduces Muscle Fatigue during Neuromuscular Electrical Stimulation
    Sayenko, Dimitry G.
    Popovic, Milos R.
    Masani, Kei
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3614 - 3617
  • [3] Method to Reduce Muscle Fatigue During Transcutaneous Neuromuscular Electrical Stimulation in Major Knee and Ankle Muscle Groups
    Sayenko, Dimitry G.
    Nguyen, Robert
    Hirabayashi, Tomoyo
    Popovic, Milos R.
    Masani, Kei
    NEUROREHABILITATION AND NEURAL REPAIR, 2015, 29 (08) : 722 - 733
  • [4] Interleaved neuromuscular electrical stimulation reduces muscle fatigue
    Lou, Jenny W. H.
    Bergquist, Austin J.
    Aldayel, Abdulaziz
    Czitron, Jennifer
    Collins, David F.
    MUSCLE & NERVE, 2017, 55 (02) : 179 - 189
  • [5] A Generic Sequential Stimulation Adapter for Reducing Muscle Fatigue during Functional Electrical Stimulation
    Ye, Gongkai
    Ali, Saima S.
    Bergquist, Austin J.
    Popovic, Milos R.
    Masani, Kei
    SENSORS, 2021, 21 (21)
  • [6] Computational Study on Spatially Distributed Sequential Stimulation for Fatigue Resistant Neuromuscular Electrical Stimulation
    Agotici, Silviu
    Masani, Kei
    Yoo, Paul B.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 2578 - 2586
  • [7] Electrical Impedance Myography for Evaluating Muscle Fatigue Induced by Neuromuscular Electrical Stimulation
    Zhou, Bin
    Zhuang, Yuandong
    Gao, Yueming
    Vasic, Zeljka Lucev
    Culjak, Ivana
    Cifrek, Mario
    Du, Min
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2022, 6 (01): : 94 - 102
  • [8] MUSCLE FATIGUE - CLINICAL IMPLICATIONS FOR FATIGUE ASSESSMENT AND NEUROMUSCULAR ELECTRICAL-STIMULATION
    BINDERMACLEOD, SA
    SNYDERMACKLER, L
    PHYSICAL THERAPY, 1993, 73 (12): : 902 - 910
  • [9] Effect of Athletic Training on Fatigue During Neuromuscular Electrical Stimulation
    Abitante, Thomas J.
    Rutkove, Seward B.
    Duda, Kevin R.
    Newman, Dava J.
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2022, 4
  • [10] Muscle Fatigue and the Importance of Electrical Stimulation Parameters on Functional Electrical Stimulation
    Moreira, Marina
    Lanari Bo, Antonio Padilha
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL 1, 2019, 70 (01): : 307 - 313