Integration of a micropreconcentrator with solid-phase microextraction for analysis of trace volatile organic compounds by gas chromatography-mass spectrometry

被引:18
|
作者
Halder, Sujoy [1 ]
Xie, Zhenzhen [1 ]
Nantz, Michael H. [2 ]
Fu, Xiao-An [1 ]
机构
[1] Univ Louisville, Dept Chem Engineenng, UnitedStates, Louisville, KY 40208 USA
[2] Univ Louisville, Dept Chem, Louisville, KY 40208 USA
关键词
VOCs; Micropreconcentrator; SPME; Two step preconcentration; GC-MS; MICROFABRICATED PRECONCENTRATOR-FOCUSER; AMBIENT AIR; BTEX; SPME; ATMOSPHERE; BENZENE; QUANTIFICATION; ETHYLBENZENE; TOLUENE; GC;
D O I
10.1016/j.chroma.2022.463083
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of toxic volatile organic compounds (VOCs) in environmental air is important because toxic VOCs induce adverse effects on human health. Although gas chromatography-mass spectrometry (GC- MS) is the standard instrument for analysis of trace VOCs in air, this mode of analysis requires precon-centration and cryogenic processes. The preconcentration and subsequent thermal desorption of VOCs require special instruments and a long time of processing sample that significantly limit applications of GC-MS for monitoring indoor and outdoor VOC levels. Using a microfabricated preconcentrator for VOC analysis also has the challenge of a large sample volume for concentration. Using solid-phase microextrac-tion (SPME) for VOC analysis by GC-MS often approaches the limit of detection of the GC-MS instrument for trace VOCs in air. This work reports a simple method to integrate microfabricated preconcentrators with commercial SPME fibers in a two-stage concentration processes to achieve rapid and reliable mea-surement of trace VOCs in air by GC-MS. We designed and fabricated a preconcentrator with micropillars in a microfluidic chamber to support sorbents and to increase the heat transfer rate to the sorbents for rapid thermal desorption. The effects of air flow rates through the preconcentrator on VOCs adsorption and thermal desorption were optimized for increasing analytical accuracy of VOCs measurements. The integration of a micropreconcentrator with SPME enabled measurements of sub-ppb levels of benzene, toluene, ethylbenzene, and xylene (BTEX), and trichloroethylene (TCE) in environmental air by GC-MS. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Sampling and analysis of volatile organic compounds in bovine breath by solid-phase microextraction and gas chromatography-mass spectrometry
    Spinhirne, JP
    Koziel, JA
    Chirase, NK
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1025 (01) : 63 - 69
  • [2] Headspace solid-phase microextraction and gas chromatography-mass spectrometry analysis of free volatile compounds inMango
    Chunqing Shang
    Chunhui Deng
    Xiaoyue Zhang
    Zhengfu Chen
    Yaoming Hu
    Chromatographia, 2002, 55 : 737 - 741
  • [3] Headspace solid-phase microextraction and gas chromatography-mass spectrometry analysis of free volatile compounds in Mango
    Shang, CQ
    Deng, CH
    Zhang, XY
    Chen, ZF
    Hu, YM
    CHROMATOGRAPHIA, 2002, 55 (11-12) : 737 - 741
  • [4] Headspace Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry for the Determination of Volatile Organic Compounds in Urine
    Drabinska, Natalia
    Starowicz, Malgorzata
    Krupa-Kozak, Urszula
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (06) : 792 - 801
  • [5] Analysis of Volatile Compounds in Agaricus Bisporus by Headspace Solid-Phase Microextraction-Gas Chromatography-Mass Spectrometry
    Yu, Xia
    Liang, Hai-Yang
    Zhao, Yan-Bo
    Cui, Li-Li
    CURRENT TOPICS IN NUTRACEUTICAL RESEARCH, 2023, 21 (04) : 524 - 530
  • [6] Quantification of 31 volatile organic compounds in whole blood using solid-phase microextraction and gas chromatography-mass spectrometry
    Blount, BC
    Kobelski, RJ
    McElprang, DO
    Ashley, DL
    Morrow, JC
    Chambers, DM
    Cardinali, FL
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (02): : 292 - 301
  • [7] Detection of Specific Volatile Organic Compounds in Tribolium castaneum (Herbst) by Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry
    Han, Shaoyun
    He, Ke
    An, Jing
    Qiao, Mengmeng
    Ke, Runhui
    Wang, Xiao
    Xu, Yang
    Tang, Xiuying
    FOODS, 2023, 12 (13)
  • [8] Methods to Detect Volatile Organic Compounds for Breath Biopsy Using Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry
    Schulz, Eray
    Woollam, Mark
    Grocki, Paul
    Davis, Michael D.
    Agarwal, Mangilal
    MOLECULES, 2023, 28 (11):
  • [9] Qualitative screening for volatile organic compounds in human blood using solid-phase microextraction and gas chromatography-mass spectrometry
    Gottzein, Anne Kathrin
    Musshoff, Frank
    Madea, Burkhard
    JOURNAL OF MASS SPECTROMETRY, 2010, 45 (04): : 391 - 397
  • [10] Determination of volatile oak compounds in wine by headspace solid-phase microextraction and gas chromatography-mass spectrometry
    Carrillo, JD
    Garrido-López, A
    Tena, MT
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) : 25 - 36