A Novel Approach for Suppression of Powerline Interference and Impulse Noise in ECG Signals

被引:0
|
作者
Bhateja, Vikrant [1 ]
Urooj, Shabana [2 ]
Verma, Rishendra [1 ]
Mehrotra, Rini [1 ]
机构
[1] Shri Ramswaroop Mem Grp Profess Coll, Dept Elect & Commun Engn, Lucknow 227105, Uttar Pradesh, India
[2] Gautam Buddha Univ, Sch Engg, Dept Elect Engg, Noida, Uttar Pradesh, India
关键词
ECG; IIR butterworth filter; powerline interference; structuring element;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
One of the major problems encountered in recording ECG is the appearance of unwanted distortions induced by power line interference in the electrocardiogram. In addition, infections due to impulse noise leads to variations in the amplitudes which represent the abnormalities associated with the heart. This paper proposes a novel approach for addressing both the aforementioned issues in ECG signals employing sub-band decomposition using wavelets analysis. Morphological filtering is applied to the detail sub-bands for removal of impulse noise using one-dimensional structuring element. Further, the powerline interference is removed using IIR Butterworth filter providing significant reduction in power spectral density levels between 50 to 60 Hz. The finally reconstructed ECG signal yields reasonably good impulse noise as well as powerline suppression using the proposed approach.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 50 条
  • [1] Powerline interference suppression in high-resolution ECG
    Bazhyna, A
    Christov, II
    Gotchev, A
    Daskalov, IK
    Egiazarian, K
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 561 - 564
  • [2] Neural Network Based Canceller for Powerline Interference in ECG Signals
    Mateo, J.
    Sanchez, C.
    Torres, A.
    Cervigon, R.
    Rieta, J. J.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 1073 - +
  • [3] An Approach to Successful Power-line Interference Suppression in ECG Signals
    Dotsinsky I.
    Dotsinsky, Ivan, 1600, Institute of Biophysics and Biomedical Engineering (26): : 83 - 92
  • [4] An adaptive denoising approach to powerline interference reduction in ECG recording
    Kumar, Manoharan Suresh
    Krishnamoorth, Ganapathy
    Vaithiyanathan, Dhandapani
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2020, 27 (04) : 939 - 951
  • [5] ECG signals reconstruction in subbands for noise suppression
    Kotas, Marian
    Moron, Tomasz
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2017, 37 (03) : 453 - 465
  • [6] Opportunities and challenges of noise interference suppression algorithms for dynamic ECG signals in wearable devices: A review
    Zhang, Juya
    Guo, Yu
    Dong, Xinming
    Wang, Tong
    Wang, Jinhai
    Ma, Xin
    Wang, Huiquan
    MEASUREMENT, 2025, 250
  • [7] Powerline interference reduction in ECG signals using empirical wavelet transform and adaptive filtering
    Department of Electronics and Communication Engineering, National Institute of Technology Jalandhar, India
    J. Med. Eng. Technol., 1 (60-68):
  • [8] Fractal and EMD based removal of baseline wander and powerline interference from ECG signals
    Agrawal, Sakshi
    Gupta, Anubha
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (11) : 1889 - 1899
  • [9] A new method based CEEMDAN for removal of baseline wander and powerline interference in ECG signals
    Yao, Liping
    Pan, Zhongliang
    OPTIK, 2020, 223
  • [10] Simultaneous powerline interference and baseline wander removal from ECG and EMG signals by sinusoidal modeling
    Zivanovic, Miroslav
    Gonzalez-Izal, Miriam
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) : 1431 - 1441