Individual-Phase-Control SVC for HVDC Link with Weak Receiving AC System

被引:0
|
作者
Qiu, Lini [1 ]
Han, Minxiao [1 ]
Yin, Weiyang [2 ]
Shi, Yan [2 ]
机构
[1] North China Elect Power Univ, Beijing, Peoples R China
[2] State Grid DC Project Construct Co Ltd, Beijing, Peoples R China
关键词
HVDC; SVC; Asymmetric fault; individual-phase-control (IPC); Voltage imbalance; Commutation failure;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an individual-phase-control (IPC) SVC compensation strategy for HVDC link with weak receiving AC side. Both uniform-phase-control (UPC) and IPC compensation policies are investigated. The paper employs PI control for the phase susceptance determination and star-delta transformation for line to line susceptance calculation. Inverter bus voltage behavior is studied and comparison is made for UPC and IPC polices considering remote asymmetric failure in the inverter AC system. The result shows that the non-fault-phase voltage will exceed rated voltage, which will deteriorate voltage performance and aggravate voltage imbalance; the fault-phase voltage will be compensated little which will lead to commutation failure when SCR of AC system is less than 1.5, if using UPC policy. While the IPC SVC compensation strategy will make the non-fault-phase voltage stay at rated voltage and fault-phase voltage compensated more, which will inhibit voltage imbalance and commutation failure effectively.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] CONTROL CHARACTERISTICS OF HVDC LINK CONNECTED TO WEAK AC SYSTEM
    KOSEKI, S
    MASADA, E
    ELECTRICAL ENGINEERING IN JAPAN, 1976, 96 (05) : 70 - 78
  • [2] Improving Fault Recovery Performance of an HVDC Link with a Weak Receiving AC System by Optimization of DC Controls
    Chao, Hong
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 4474 - 4479
  • [3] INTERCONNECTING A WEAK AC SYSTEM TO AN HVDC LINK WITH A HYBRID INVERTER
    TAM, KS
    LONG, WF
    LASSETER, RH
    ELECTRIC POWER SYSTEMS RESEARCH, 1988, 14 (02) : 121 - 128
  • [4] Evaluation of control schemes for a hvdc system feeding into a weak ac system
    Indian Inst of Technology, Kanpur, India
    J Indian Inst Sci, 6 (535-554):
  • [5] PERFORMANCE EVALUATION OF AN HVDC LINK WITH A CAPACITOR COMMUTATED INVERTER CONNECTED TO A VERY WEAK RECEIVING AC NETWORK
    Khatir, Mohamed
    Zidi, Sid-Ahmed
    Fellah, Mohammed-Karim
    Hadjeri, Samir
    Amiri, Rabie
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2009, 60 (04): : 209 - 214
  • [6] PROTECTING A HVDC LINK AGAINST ACCIDENTAL ISOLATION FROM ITS RECEIVING AC SYSTEM
    WHITEHOUSE, RS
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1586 - 1590
  • [7] Review of HVDC control in weak AC grids
    Khazaei, Javad
    Idowu, Peter
    Asrari, Arash
    Shafaye, A. B.
    Piyasinghe, Lakshan
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 162 : 194 - 206
  • [8] Power decoupling control design of the VSC-HVDC under the weak receiving AC grid conditions
    Shao B.-B.
    Jia J.-X.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2022, 26 (10): : 56 - 65
  • [9] Dynamic Reactive Compensation Requirements at the Rectifier End of an LCC HVDC Link Connected to a Weak AC System
    ElMehdi, Abosalah
    Momen, Ahmed
    Johnson, Brian K.
    2014 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2014,
  • [10] Three phase harmonic load flow in an unbalanced AC system including HVDC link
    Hosseini, SH
    Sajadi, A
    Teimouri, M
    IPEMC 2004: THE 4TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2004, : 1726 - 1730