Improvement of the penumbra for small radiosurgical fields using flattening filter free low megavoltage beams

被引:16
|
作者
Yarahmadi, Mehran [1 ]
Allahverdi, Mahmoud [2 ]
Nedaie, Hassan A. [2 ]
Asnaashari, Khadijeh [2 ]
Vaezzadeh, Sayed A. [2 ]
Sauer, Otto A. [3 ]
机构
[1] Kurdistan Univ Med Sci, Sanandaj, Iran
[2] Univ Tehran Med Sci, Tehran, Iran
[3] Univ Wurzburg, Klin & Poliklin Strahlentherapie, D-97080 Wurzburg, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2013年 / 23卷 / 04期
关键词
Small field; penumbra; flattening filter; Monte Carlo; MONTE-CARLO-SIMULATION; FREE CLINICAL ACCELERATOR; UNFLATTENED PHOTON BEAMS; LINEAR-ACCELERATOR; STEREOTACTIC RADIOSURGERY; DOSIMETRIC PROPERTIES; ELECTRON-TRANSPORT; OUTPUT FACTORS; ION-CHAMBER; MV;
D O I
10.1016/j.zemedi.2013.03.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In stereotactic radiosurgery, sharp beam edges have clear advantages to spare normal tissues. In general, the dose gradient is a limiting factor in minimizing dose to nearby critical structures for clinical cases. Therefore the penumbral width should be diminished. Methods: A Varian Clinac 2100 linear accelerator equipped with in-house designed radiosurgical collimator was modeled using the EGSnrc/BEAMnrc Monte Carlo code and compared with the measurements. The 0.015 cm(3) PinPoint chamber was used to measure the 6 MV photon beam characteristics and to validate Monte Carlo calculations. Additional to the standard (STD) linac, a flattening filter free (FFF) linac was simulated. Percent depth doses, beam profiles and output factors were calculated for small field sizes with diameter of 5, 10, 20 and 30 mm with DOSXYZnrc. The mean energy and photon fluence at the water surface were calculated with BEAMDP for both FFF linac and STD linacs. Results: The penumbra width (80%-20%) was decreased by 0.5, 0.3, 0.2 and 0.2 mm for field sizes of 5, 10, 20 and 30 mm respectively when removing the FE The fluence of photons at the surface increased up to 3.6 times and the mean energy decreased by a factor of 0.69 when removing the FE The penumbra width (80%-20%) decreased by 17% when a 2 MeV monoenergetic electron pencil beam incident on the target is used instead of 6.2 MeV. Conclusions: It was found that the penumbra of small field sizes is decreased by removing the FF. Likewise using low megavoltage photons reduced the beam penumbra maintaining adequate penetration and skin sparing.
引用
收藏
页码:291 / 299
页数:9
相关论文
共 50 条
  • [1] Small Field Dosimetry of Flattening Filter Free Beams
    Popple, R.
    Shen, S.
    Duan, J.
    Wu, X.
    Brezovich, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [2] Characterization of a new stereotactic diode under flattening filter free beams down to small fields
    Reggiori, G.
    Mancosu, P.
    Stravato, A.
    Lobefalo, F.
    Paganini, L.
    Zucconi, F.
    Palumbo, V.
    Suchowerska, N.
    Tomatis, S.
    Scorsetti, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S702 - S702
  • [3] Small field dosimetry for flattening filter free photon beams
    Mateus, D.
    Beyer, G.
    Vieira, S.
    Greco, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S425 - S426
  • [4] Evaluation of beam modeling for small fields using a flattening filter-free beam
    Kawahara D.
    Ozawa S.
    Nakashima T.
    Aita M.
    Tsuda S.
    Ochi Y.
    Okumura T.
    Masuda H.
    Ohno Y.
    Murakami Y.
    Nagata Y.
    Radiological Physics and Technology, 2017, 10 (1) : 33 - 40
  • [5] Characteristics of flattening filter free beams at low monitor unit settings
    Akino, Yuichi
    Ota, Seiichi
    Inoue, Shinichi
    Mizuno, Hirokazu
    Sumida, Iori
    Yoshioka, Yasuo
    Isohashi, Fumiaki
    Ogawa, Kazuhiko
    MEDICAL PHYSICS, 2013, 40 (11)
  • [6] A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment
    Ali Wagdy
    Khaled EI Shahat
    Huda Ashry
    Amaal El Shershaby
    Ehab Abdo
    OncologyandTranslationalMedicine, 2017, 3 (06) : 260 - 266
  • [7] Commissioning Measurements of Flattening Filter and Flattening Filter Free Photon Beams Using a TrueBeam Stx® Linear Accelerator
    Saidi K.
    El Baydaoui R.
    El Gouach H.
    Mesradi M.R.
    Naim A.
    Iranian Journal of Medical Physics, 2021, 18 (01) : 49 - 62
  • [8] Challenges in the Dosimetry of Flattening Filter Free Beams
    Czarnecki, D.
    von Voigts-Rhetz, P.
    Zink, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 566 - 567
  • [9] Penumbra Measurement for a Flattening-Filter-Free Artiste Linear Accelerator
    Gayou, O.
    Johnson, M.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Small field dosimetry and analysis of flattening filter free beams in true beam system
    Muralidhar, K. R.
    Rout, Birendra Kumar
    Ramesh, K. K. D.
    Ali, Mirza Athar
    Madhusudhan, N.
    Komanduri, Krishna
    Babaiah, M.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (01) : 136 - 140